DOWNLOAD JBL SOUNDFLY BT (serv.man3) Service Manual ↓ Size: 3.17 MB | Pages: 75 in PDF or view online for FREE

Model
SOUNDFLY BT (serv.man3)
Pages
75
Size
3.17 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundfly-bt-sm3.pdf
Date

JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 12 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1 
a) Open circuit voltages  
See appended table for detail. 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
See appended table for detail. 
 
c) Discharge not exceeding 45 
μC  
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access with test finger or 
test probe to any parts bearing 
hazardous voltage. 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No hazardous live parts can be 
touched by the metal test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
The test probe did not become 
hazardous live parts after test. 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
No access to any parts at 
hazardous voltage. 
9.1.5 
Pre‑ set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
The voltage of pins or contacts 
for the mains plug no exceed 
hazardous live after 2 seconds. 
Test voltage: 264V/60Hz, 
Measured voltage: 30V. 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
See below. 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Hazardous live part is not 
accessible. 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Hazardous live part is not 
accessible. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N force applied. Hazardous 
live part is not accessible. 
9.2 
No hazard after removing a cover by hand  
 
N/A 
 
10 
Insulation requirements 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ................................................................. : 
Surge test with 50 discharges 
at a maximum rate of 12/min 
from a 1 nF capacitor charged 
to 10kV performed. Measured 
greater than 4 M
Ω between 
mains supply terminals to RCA 
input terminals. 
 
Page 13 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 
At 40 
o
C, R.H. 95%, 168 hrs. 
After the tests, the tests of 10.3 
are made and pass. 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 
11 
Fault conditions 
11.1 
No shock hazard under fault condition  
No electric shock during fault 
operation.                            
(see appended table 11.2) 
11.2 
Heating under fault condition  
(see appended table 11.2) 
 
Flames extinguish within 10 seconds  
No solder became softening 
during the tests. 
 
No hazard from softening solder  
 
N/A 
 
Soldered terminations not used  as protective 
mechanism  
 
N/A 
11.2.1 
Measurement of temperature rises  
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts  
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table 11.2) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
(see appended table 11.2) 
11.2.5 
Temperature rise of windings  
(see appended table 11.2) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
(see appended table 11.2) 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ................ : 
 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 
N/A 
 
Class I protective earthing maintained  
 
N/A 
 
Page 14 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
 
N/A 
 
12 
Mechanical strength 
12.1.1 
Bump test where mass >7 kg  
Apparatus with a mass less 
than 7kg. 
N/A 
12.1.2 
Vibration test  
No damage to the apparatus 
after the vibration test. 
12.1.3 
Impact hammer test  
 
N/A 
 
Steel ball test  
 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg   Test conducted and all 
compliance criteria were 
passed. 
12.1.5 
Thermoplastic enclosures stress relief test  
After 70
 o
C for a period of 7 
hours and cooling down to 
room temperature, no 
dangerous moving parts or 
hazards live parts became 
accessible. 
12.2 
Fixing of knobs, push buttons, keys and levers  
No hazardous live parts 
incorporated. 
N/A 
12.3 
Remote controls with hazardous live parts  
No hazardous live parts 
incorporated. 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
No drawers provided. 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
No antenna coaxial sockets 
provided. 
N/A 
12.6 
Telescoping or rod antennas construction  
No such construction. 
N/A 
12.6.1 
Telescoping or rod antennas securement  
See above. 
N/A 
 
13 
Clearances and creepage distances 
13.1 
Clearances in accordance with 13.3  
Clearance measured 
according to annex E.   
Pollution degree 2 was 
considered. 
 
Creepage distances in accordance with 13.4  
Clearance measured 
according to annex E.   
Pollution degree 2 was 
considered. 
13.2 
Determination of working voltage  
The apparatus was connected 
to a 120 or 230V TN power 
system. 
13.3 
Clearances  
See below. 
 
Page 15 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
13.3.1 
General  
(see appended table 13) 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ............. : 
(see appended table 13) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
Accessible parts circuits 
verified by short-circuit tests 
according to 4.3.1. 
13.3.4 
Measurement of transient voltages  
Normal transient voltage 2500 
V considered (overvoltage 
category II for primary circuits). 
13.4 
Creepage distances  
(see appended table 13) 
 
Creepage distances greater than table 11 minimum 
values  
Considered. 
13.5 
Printed boards  
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664‑ 3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 
N/A 
 
14 
Components 
14.1 
Resistors  
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such components. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
No such components. 
N/A 
 
Resistors separately approved  ............................... : 
No such components. 
N/A 
14.2 
Capacitors and RC units  
See below. 
Page of 75
Display