JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate ▷ View online
Page 12 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
See appended table for detail.
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See appended table for detail.
P
c) Discharge not exceeding 45
μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
No access with test finger or
test probe to any parts bearing
hazardous voltage.
test probe to any parts bearing
hazardous voltage.
P
9.1.2
No hazardous live shafts of knobs, handles or levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No hazardous live parts can be
touched by the metal test pin.
touched by the metal test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
The test probe did not become
hazardous live parts after test.
hazardous live parts after test.
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
No access to any parts at
hazardous voltage.
hazardous voltage.
P
9.1.5
Pre‑ set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
The voltage of pins or contacts
for the mains plug no exceed
hazardous live after 2 seconds.
Test voltage: 264V/60Hz,
Measured voltage: 30V.
for the mains plug no exceed
hazardous live after 2 seconds.
Test voltage: 264V/60Hz,
Measured voltage: 30V.
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
See below.
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Hazardous live part is not
accessible.
accessible.
P
b) Test hook of fig. 4 for 10 s (20 N)
Hazardous live part is not
accessible.
accessible.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N force applied. Hazardous
live part is not accessible.
live part is not accessible.
P
9.2
No hazard after removing a cover by hand
N/A
10
Insulation requirements
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ................................................................. :
Surge test with 50 discharges
at a maximum rate of 12/min
from a 1 nF capacitor charged
to 10kV performed. Measured
greater than 4 M
at a maximum rate of 12/min
from a 1 nF capacitor charged
to 10kV performed. Measured
greater than 4 M
Ω between
mains supply terminals to RCA
input terminals.
input terminals.
P
Page 13 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.2
Humidity treatment 48 h or 120 h ........................... :
At 40
o
C, R.H. 95%, 168 hrs.
After the tests, the tests of 10.3
are made and pass.
are made and pass.
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
No electric shock during fault
operation.
(see appended table 11.2)
operation.
(see appended table 11.2)
P
11.2
Heating under fault condition
(see appended table 11.2)
P
Flames extinguish within 10 seconds
No solder became softening
during the tests.
during the tests.
P
No hazard from softening solder
N/A
Soldered terminations not used as protective
mechanism
mechanism
N/A
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table 11.2)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
(see appended table 11.2)
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
Page 14 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
N/A
12
Mechanical strength
P
12.1.1
Bump test where mass >7 kg
Apparatus with a mass less
than 7kg.
than 7kg.
N/A
12.1.2
Vibration test
No damage to the apparatus
after the vibration test.
after the vibration test.
P
12.1.3
Impact hammer test
N/A
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg Test conducted and all
compliance criteria were
passed.
passed.
P
12.1.5
Thermoplastic enclosures stress relief test
After 70
o
C for a period of 7
hours and cooling down to
room temperature, no
dangerous moving parts or
hazards live parts became
accessible.
room temperature, no
dangerous moving parts or
hazards live parts became
accessible.
P
12.2
Fixing of knobs, push buttons, keys and levers
No hazardous live parts
incorporated.
incorporated.
N/A
12.3
Remote controls with hazardous live parts
No hazardous live parts
incorporated.
incorporated.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers provided.
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial sockets
provided.
provided.
N/A
12.6
Telescoping or rod antennas construction
No such construction.
N/A
12.6.1
Telescoping or rod antennas securement
See above.
N/A
13
Clearances and creepage distances
P
13.1
Clearances in accordance with 13.3
Clearance measured
according to annex E.
Pollution degree 2 was
considered.
according to annex E.
Pollution degree 2 was
considered.
P
Creepage distances in accordance with 13.4
Clearance measured
according to annex E.
Pollution degree 2 was
considered.
according to annex E.
Pollution degree 2 was
considered.
P
13.2
Determination of working voltage
The apparatus was connected
to a 120 or 230V TN power
system.
to a 120 or 230V TN power
system.
P
13.3
Clearances
See below.
P
Page 15 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.3.1
General
(see appended table 13)
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............. :
with table 8 and, where applicable, table 9 ............. :
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Accessible parts circuits
verified by short-circuit tests
according to 4.3.1.
verified by short-circuit tests
according to 4.3.1.
P
13.3.4
Measurement of transient voltages
Normal transient voltage 2500
V considered (overvoltage
category II for primary circuits).
V considered (overvoltage
category II for primary circuits).
P
13.4
Creepage distances
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values
values
Considered.
P
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664‑ 3 (basic insulation only)
IEC 60664‑ 3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14
Components
P
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such components.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
No such components.
N/A
Resistors separately approved ............................... :
No such components.
N/A
14.2
Capacitors and RC units
See below.
P
Click on the first or last page to see other SOUNDFLY BT (serv.man3) service manuals if exist.