Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
14.12 
Surge suppression varistors  
Varistor  was connected 
between mains lines. Certified 
sources of varistor with 
suitable rating used.            
See appended table 14 for 
details. 
 
Comply with IEC 61051-2  
See above. 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
See above. 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
See above. 
 
15 
Terminals 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved mains plug 
provided. See appended table 
14 for the details. 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
See below. 
 
No risk of insertion in mains socket-outlets  
None of mismatch of 
connectors to AC mains 
occurred. 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets  
 
N/A 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  ................... : 
0.001
 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
N/A 
 
Page 21 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board    
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 
N/A 
 
Wire secured by additional means to the  
conductor   
 
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16    
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 
N/A 
15.4 
Devices forming a part of the mains plug  
Direct plug-in equipment. 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
N/A 
 
Page 22 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ : 
 
N/A 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
 
N/A 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of 
IEC 60227‑ 2)  
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
 
N/A 
16.5 
Adequate strain relief on external flexible cords  
 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor  
 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320‑ 1  
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 
N/A 
 
17 
Electrical connections and mechanical fixings 
17.1 
Torque test to table 20  
See below. 
 
- screws into metal: 5 times  
Complied.                        
Screw diameter: 2.0mm, 
Torque: 0.5Nm 
 
- screws into non-metallic material: 10 times  
 
N/A 
 
Page 23 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
17.2 
Correct introduction into female threads in non-
metallic material  
No screws into female threads 
in non-metallic. 
N/A 
17.3 
Cover fixing screws: captive  
No captive fixing screws sued. 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
No cause reduction of 
clearances and creepage 
distance when replaced by 
screw with length which is 10 
times its diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
All conductive parts are fixed 
on PCB by soldering and 
mechanical fixing. 
N/A 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
Complied. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder  
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
 
N/A 
17.9 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
N/A 
18.1 
Picture tube separately approved to IEC 61965  .... : 
 
N/A 
 
Picture tube separately approved to 18.2  .............. : 
 
N/A 
18.2 
Non-intrinsically protected tubes tested to 18.2 
 
N/A 
 
19 
Stability and mechanical hazards 
 
Mass of the equipment exceeding 7 kg  ................. : 
The equipment mass is less 
than 7kg. 
N/A 
 
Apparatus intended to be fastened in place 
– 
suitable instructions  ................................................ : 
 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
 
N/A 
19.2 
100 N force applied vertically downwards  
 
N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability  
 
N/A 
19.4 
Edges or corners not hazardous  
Edges or corners are 
smoothed. 
Page of 75
Display