Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Capacitors separately approved :
(see appended table 14)
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition
……:
Between the hazardous live
and accessible conductive
part: Y capacitors subclass Y1
according to IEC 60384-14
with 21 days damp heat test.
(see appended table 14)
and accessible conductive
part: Y capacitors subclass Y1
according to IEC 60384-14
with 21 days damp heat test.
(see appended table 14)
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition
……:
Between the lines: X
capacitors subclass X1 or X2
according to IEC 60384-14
with 21 days damp heat test.
(see appended table 14)
capacitors subclass X1 or X2
according to IEC 60384-14
with 21 days damp heat test.
(see appended table 14)
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such components.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................ :
metal ........................................................................ :
The capacitor with volume is
small than 1750mm³.
small than 1750mm³.
P
14.3
Inductors and windings
See below.
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
Transformer marked with
manufacturer
manufacturer
’s name and type.
P
Transformers and inductors separately approved . :
N/A
14.3.2
General
See subclauses 14.3.3, 14.3.4.
and 14.3.5.
and 14.3.5.
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
See below.
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Transformer is complied with
clause 13.
clause 13.
P
14.3.3.2
Transformers meet the constructional requirements
Complied.
P
14.3.4
Separation between windings
See below.
P
Page 17 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) .............................. :
between hazardous live parts and accessible parts
(double or reinforced insulation) .............................. :
Double insulation separated
between hazardous live
windings and windings
intended to be connected to
accessible conductive parts.
See also sub-clause 8.8 and
appended table 14 for details.
between hazardous live
windings and windings
intended to be connected to
accessible conductive parts.
See also sub-clause 8.8 and
appended table 14 for details.
P
Coil formers and partition walls > 0,4 mm
(see appended table 14.3.4)
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
P
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
See below.
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double insulation separated
between hazardous live
windings and accessible parts
or parts intend to be connected
to accessible conductive parts.
See also sub-clause 8.8 and
appended table 14 for details.
between hazardous live
windings and accessible parts
or parts intend to be connected
to accessible conductive parts.
See also sub-clause 8.8 and
appended table 14 for details.
P
Coil formers and partition walls > 0,4 mm
(see appended table 14.3.4)
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
P
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
High‑ voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
See below.
P
Protective devices used within their ratings
(see appended table 14)
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
(see appended table 13)
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
Page 18 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
(see appended table 14)
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Fuse marked on PCB of SPS
adjacent to component as:
F1 T3.15AL/250V
adjacent to component as:
F1 T3.15AL/250V
P
14.5.2.3
Not possible to connect fuses in parallel ................ :
N/A
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
N/A
14.5.3
PTC thermistors comply with IEC 60730-1:2007
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N/A
14.6
Switches
N/A
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
Page 19 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950-1
N/A
14.8
Voltage setting devices and the like
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N/A
14.10
Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
See below.
P
a) Comply with 13.6 (jointed insulation) and N.2.1
See appended tables 13.1 and
14 for the details.
14 for the details.
P
b) Comply with IEC 60747-5-5:2007
N/A
Alternative to a) and b) optocoupler comply with 13.8 Approved optocoupler was
used, see appended table 14
for the details.
for the details.
P
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A