Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension 
> 450 mm, pass the test of 19.5.1  
 
N/A 
19.6 
Wall or ceiling mountings adequate  
 
N/A 
 
20 
Resistance to fire 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
Not applied. 
 
b) Exemption for small components as defined in 
20.1  
All components smaller than 
1750mm
2
 are mounted on a 
PCB with V-1 rating. 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4  
See sub-clause 14 and 20.1.4 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure  
The PCB with material of 
flammability category V-1 or 
better used. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
For SPS only: The PCB with 
material of flammability 
category V-0 or batter used. 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
See above. 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 
N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 
N/A 
 
Page 25 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
20.2.2 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
N/A 
A.5 
Marking and instructions 
IPX0 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 
N/A 
A.10 
Insulation requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1  
 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
N/A 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 
N/A 
 
Page 26 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 
Insulation requirements 
 
N/A 
L. 10.3.2 
High frequency pulse ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page 27 of  38 
Report No. : 12-1330-0056 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF/Stand-by mode of 
the functional switch (W)  ......................................... : 
-- 
N/A 
  
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
90V/50Hz 
0.19 
10.4 
-- 
90V/60Hz 
0.19 
10.4 
-- 
100V/50Hz 
0.19 
10.4 
-- 
100V/60Hz 
0.19 
10.3 
-- 
240V/50Hz 
0.11 
10.4 
-- 
240V/60Hz 
0.11 
10.4 
-- 
264V/50Hz 
0.10 
10.3 
-- 
264V/60Hz 
0.10 
10.5 
-- 
 
Loudspeaker i
mpedance (Ω)  .................................. : 
See appended table 14 
— 
 
Several loudspeaker systems ................................. : 
-- 
N/A 
 
Marking of loudspeaker terminals ........................... : 
-- 
N/A 
 
Temperature Rise dT of Part 
dT (K) 
Limit max dT (K) 
Test condition: Horizontal 
Test voltage: 
90V/60Hz 
264V/60Hz 
-- 
PWB under U10 (M/B) 
41.8 
42.1 
85 
T1 coil (SPS) 
45.6 
47.4 
95 
T1 core (SPS) 
43.8 
46.5 
95 
CY1 body (SPS) 
48.6 
36.5 
80 
U2 body (SPS) 
30.6 
31.4 
55 
CX1 body (SPS) 
37.0 
30.2 
55 
LF1 coil (SPS) 
42.4 
31.3 
85 
PWB under BD1 (SPS) 
38.7 
34.1 
85 
PWB under Q1 (SPS) 
41.6 
43.6 
85 
C7 body (SPS) 
39.7 
26.3 
55 
PWB under D7 (SPS) 
27.7 
31.4 
85 
Enclosure inside near T1  
16.4 
18.6 
30 
Enclosure outside near T1 
5.8 
15.9 
50 
Plug holder 
5.0 
15.0 
30 
Ambient 
24.6 °C 
23.7 °C 
-- 
Test condition: Vertical 
Test voltage: 
90V/60Hz 
264V/60Hz 
-- 
PWB under U10 (M/B) 
28.1 
33.3 
85 
T1 coil (SPS) 
34.3 
46.1 
95 
T1 core (SPS) 
32.9 
43.6 
95 