JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate ▷ View online
Page 24 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A
20
Resistance to fire
P
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
Not applied.
P
b) Exemption for small components as defined in
20.1
20.1
All components smaller than
1750mm
1750mm
2
are mounted on a
PCB with V-1 rating.
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
See sub-clause 14 and 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
The PCB with material of
flammability category V-1 or
better used.
flammability category V-1 or
better used.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
For SPS only: The PCB with
material of flammability
category V-0 or batter used.
material of flammability
category V-0 or batter used.
P
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
See above.
P
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
Page 25 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
20.2.2
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
N/A
A.5
Marking and instructions
IPX0
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10
Insulation requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
N/A
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
N/A
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Page 26 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10
Insulation requirements
N/A
L. 10.3.2
High frequency pulse ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 27 of 38
Report No. : 12-1330-0056
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
7.1
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W) ......................................... :
the functional switch (W) ......................................... :
--
N/A
Un (V)
In (A)
Pn (W)
Pout (W)
90V/50Hz
0.19
10.4
--
90V/60Hz
0.19
10.4
--
100V/50Hz
0.19
10.4
--
100V/60Hz
0.19
10.3
--
240V/50Hz
0.11
10.4
--
240V/60Hz
0.11
10.4
--
264V/50Hz
0.10
10.3
--
264V/60Hz
0.10
10.5
--
Loudspeaker i
mpedance (Ω) .................................. :
See appended table 14
—
Several loudspeaker systems ................................. :
--
N/A
Marking of loudspeaker terminals ........................... :
--
N/A
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test condition: Horizontal
Test voltage:
90V/60Hz
264V/60Hz
--
PWB under U10 (M/B)
41.8
42.1
85
T1 coil (SPS)
45.6
47.4
95
T1 core (SPS)
43.8
46.5
95
CY1 body (SPS)
48.6
36.5
80
U2 body (SPS)
30.6
31.4
55
CX1 body (SPS)
37.0
30.2
55
LF1 coil (SPS)
42.4
31.3
85
PWB under BD1 (SPS)
38.7
34.1
85
PWB under Q1 (SPS)
41.6
43.6
85
C7 body (SPS)
39.7
26.3
55
PWB under D7 (SPS)
27.7
31.4
85
Enclosure inside near T1
16.4
18.6
30
Enclosure outside near T1
5.8
15.9
50
Plug holder
5.0
15.0
30
Ambient
24.6 °C
23.7 °C
--
Test condition: Vertical
Test voltage:
90V/60Hz
264V/60Hz
--
PWB under U10 (M/B)
28.1
33.3
85
T1 coil (SPS)
34.3
46.1
95
T1 core (SPS)
32.9
43.6
95
Click on the first or last page to see other SOUNDFLY BT (serv.man3) service manuals if exist.