<12014238 001 > 
 
 
Page 40 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
Storage Cap. 
(C2) 
Various 
Various 
4.7-47µF;  
Min. 400VDC; 105°C 
-- 
-- 
Euro-plug 
 
Dee Van 
Enterprise Co., 
Ltd. 
DVE 
2.5A; 250VAC 
EN 50075 
TÜV 
Rheinland  
(J 2156136) 
BS plug 
Dee Van 
Enterprise Co., 
Ltd. 
DVE-UK 
0.7A; 250VAC 
BS 1363 
Tested with 
appliance 
Insulation 
material of BS 
plug holder 
GE Plastics Co., 
Ltd. 
SE1X 
PPE+PS; V-1; 105°C; 
thickness: min. 0.8mm  
-- 
UL  
Insulation 
material of 
Australian plug 
Dupont  
FR50 
PA66, 130°C, V-0 
-- 
UL 
Enclosure  
GE Plastics Co., 
Ltd. 
SE1X 
PPE+PS; V-1;  
105°C; thickness: min. 
2.0mm  
-- 
UL  
Insulation tape 
Four Pillars 
35660Y/MY130  130°C 
--  
UL  
Primary lead 
wire 
Various  
1007 
105°C; min. 24AWG; 
VW-1; 300V 
-- 
UL 
Output cord 
Various 
Various 
80°C; min. 22AWG; 
VW-1 
-- 
UL  
Output cord (if 
the part in 
enclosure 
covered with 
heat shrinkable 
tube) 
Various 
Various 
60°C; min. 22AWG; 
VW-1 
-- 
UL  
Heat shrinkable 
tube 
Various 
Various 
125°C; 600V; VW-1 
--  
UL  
PCB 
Various 
Various 
V-0 or better;  
min. 130°C 
-- 
UL  
Note(s): 
An asterisk indicates a mark that assures the agreed level of surveillance. 
 
1.6.2 
TABLE: electrical data (in normal conditions) 
Fuse #  Irated (mA) 
U (V) 
P (W) 
I (mA) 
Ifuse (mA)  Condition/status 
Model DSA-20R-12 FEU 090180 
F1 
-- 
90 
22.5 
421 
421 
Rated load at 50 Hz 
F1 
-- 
90 
22.3 
434 
434 
Rated load at 60 Hz 
F1 
700 
100 
22.1 
371 
371 
Rated load at 50 Hz 
F1 
700 
100 
22.1 
402 
402 
Rated load at 60 Hz 
F1 
700 
240 
22.1 
226 
226 
Rated load at 50 Hz 
F1 
700 
240 
22.0 
213 
213 
Rated load at 60 Hz 
 
 
<12014238 001 > 
 
 
Page 41 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
F1 
-- 
264 
22.2 
218 
218 
Rated load at 50 Hz 
F1 
-- 
264 
22.2 
207 
207 
Rated load at 60 Hz 
Model DSA-20R-12 FEU 102204 
F1 
-- 
90 
25.3 
476 
476 
Rated load at 50 Hz 
F1 
-- 
90 
25.3 
484 
484 
Rated load at 60 Hz 
F1 
700 
100 
24.9 
417 
417 
Rated load at 50 Hz 
F1 
700 
100 
25.0 
447 
447 
Rated load at 60 Hz 
F1 
700 
240 
24.6 
246 
246 
Rated load at 50 Hz 
F1 
700 
240 
24.6 
234 
234 
Rated load at 60 Hz 
F1 
-- 
264 
25.1 
238 
238 
Rated load at 50 Hz 
F1 
-- 
264 
24.9 
228 
228 
Rated load at 60 Hz 
Model DSA-20R-12 FEU 150204 
F1 
-- 
90 
24.6 
459 
459 
Rated load at 50 Hz 
F1 
-- 
90 
24.6 
470 
470 
Rated load at 60 Hz 
F1 
700 
100 
24.3 
409 
409 
Rated load at 50 Hz 
F1 
700 
100 
24.3 
433 
433 
Rated load at 60 Hz 
F1 
700 
240 
24.3 
244 
244 
Rated load at 50 Hz 
F1 
700 
240 
24.3 
230 
230 
Rated load at 60 Hz 
F1 
-- 
264 
24.7 
234 
234 
Rated load at 50 Hz 
F1 
-- 
264 
24.5 
224 
224 
Rated load at 60 Hz 
Note(s):-- 
 
2.1.1.5 
TABLE: max. V, A, VA test  
Voltage (rated) 
(V) 
Current (rated) 
(A) 
Voltage (max.) 
(V) 
Current (max.) 
(A) 
VA (max.) 
(VA) 
Model DSA-20R-12 FEU 150204 
15.0 
1.36 
14.9 
2.52 
26.2 
Model DSA-20R-12 FEU 102204 
10.2 
2.00 
10.2 
2.98 
22.8 
Note(s): 
Test voltage: 
240 V 
Test frequency: 60 Hz 
 
2.1.1.7 
TABLE: discharge test 
N/A 
Condition 
τ
 calculated 
(s) 
τ
 measured 
(s) 
t u→ 0V 
(s) 
Comments 
 
 
 
 
 
 
 
<12014238 001 > 
 
 
Page 42 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
 
 
 
 
Note(s): -- 
 
2.2.2 
TABLE: Hazardous voltage measurement 
max. Voltage 
Transformer  
Location 
V peak 
V d.c. 
Voltage Limitation 
Component 
Model DSA-20R-12 FEU 150204 
T1 
8-10 
34.8 
-- 
D9 
 
Output  
-- 
14.9 
 
Note(s): 
Test voltage:240 V 
Test frequency: 60 Hz 
The limits of SELV were not exceeded between any two points of the secondary circuit. 
 
2.2.3 
TABLE: SEL voltage measurement 
Location 
Voltage measured (V) 
Comments 
Model DSA-20R-12 FEU 150204 
Output 
Short-circuit D9, circuit protected immediately. 
Note(s): -- 
 
2.4.2 
TABLE: limited current circuit measurement 
N/A 
Location 
Voltage 
(V) 
Current 
(mA) 
Freq. 
(kHz) 
Limit 
(mA) 
Comments 
 
 
 
 
 
 
 
Note(s):  
Test voltage: 
-- 
Test frequency:  -- 
 
2.5 
TABLE: limited power source measurement 
 
Limits 
Measured 
Verdict 
Model DSA-20R-12 FEU 150204 
Uoc = 14.9 V (measured under no load conditions) 
According to Table 2B (normal condition) 
current (in A) 
≤8 
2.52 
apparent power (in VA) 
≤5*Uoc= 74.5 
26.2 
According to Table 2B (Opto-coupler primary open-circuited) 
 
 
<12014238 001 > 
 
 
Page 43 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
current (in A) 
≤8 
2.53 
apparent power (in VA) 
≤5*Uoc= 74.5 
26.8 
According to Table 2B (Opto-coupler primary short-circuited) 
current (in A) 
≤8 
0 (unit shut down) 
apparent power (in VA) 
≤5*Uoc= 74.5 
0 (unit shut down) 
According to Table 2B (Opto-coupler secondary open-circuited) 
current (in A) 
≤8 
2.50 
apparent power (in VA) 
≤5*Uoc= 74.5 
27.1 
According to Table 2B (Opto-coupler secondary short-circuited) 
current (in A) 
≤8 
2.80 
apparent power (in VA) 
≤5*Uoc= 74.5 
28.1 
Model DSA-20R-12 FEU 090180 
Uoc = 9.0 V (measured under no load conditions) 
According to Table 2B (normal condition) 
current (in A) 
≤8 
3.13 
power (in VA) 
≤5*Uoc=45.0 
22.5 
According to Table 2B (Opto-coupler primary open-circuited) 
current (in A) 
≤8 
2.94 
power (in VA) 
≤5*Uoc=45.0 
27.6 
According to Table 2B (Opto-coupler primary short-circuited) 
current (in A) 
≤8 
0 (unit shut down) 
power (in VA) 
≤5*Uoc=45.0 
0 (unit shut down) 
According to Table 2B (Opto-coupler secondary open-circuited) 
current (in A) 
≤8 
3.12 
power (in VA) 
≤5*Uoc=45.0 
26.3 
According to Table 2B (Opto-coupler secondary short-circuited) 
current (in A) 
≤8 
3.07 
power (in VA) 
≤5*Uoc=45.0 
29.3 
Note(s): -- 
 
2.6.3.3 
TABLE: ground continue test 
N/A 
Location 
Resistance measured (mΩ)  Comments 
 
 
 
 
 
 
 
 
 
Note(s): -- 
Page of 78