DOWNLOAD JBL ON STAGE III IIIP (serv.man2) Service Manual ↓ Size: 1.55 MB | Pages: 78 in PDF or view online for FREE

Model
ON STAGE III IIIP (serv.man2)
Pages
78
Size
1.55 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-iii-iiip-sm2.pdf
Date

JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12014238 001 > 
 
 
Page 52 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
Over 3 up to and 
including 7.5 
0.75 
16 [1.3] 
Over 7.5 up to 
and including 10 
(0.75)
2)
 1.00 
16 [1.3] 
Over 10 up to 
and including 16 
(1.0)
3)
 1.5 
14 [2] 
Replace footnote 1) with the following: 
1)
  This  nominal  cross-sectional  area  is  only 
allowed for Class II appliances if the length of the 
power  supply  cord,  measured  between  the  point 
where  the  cord,  or  cord  guard,  enters  the 
appliances,  and  the  entry  to  the  plug  does  not 
exceed  2  m  (0.5  mm²  three-core  supply  flexible 
cords are not permitted; see AS/NZS 3191).  
Delete Note 1. 
4.3.6 
Replace paragraph three with:  
Equipment with a plug portion, suitable for 
insertion into a 10 A 3-pin flat-pin socket-outlet 
complying with AS/NZS 3112, shall comply with 
the requirements in AS/NZS 3112 for equipment 
with integral pins for insertion into socket-outlets.  
Replaced. 
N/A 
4.3.13.5 
Add the following to the end of the first paragraph:  
", or AS/NZS 2211.1"  
Added. 
4.7 
Add the following paragraph: 
For alternative tests refer to clause 4.7.201.  
Added.  
4.7.201 
Add the following after clause 4.7.3.6: 
4.7.201 Resistance to fire - Alternative tests 
Added.  
4.7.201.1 
General 
Parts of non-metallic material shall be resistant to 
ignition and spread of fire. 
This requirement does not apply to decorative 
trims, knobs and other parts unlikely to be ignited 
or to propagate flames originating from inside the 
apparatus, or the following: 
(a)  Components that are contained in an 
enclosure having a flammability category of 
FV-0 according to AS/NSZ 4695.707 and 
having openings only for the connecting wires 
filling the openings completely, and for the 
ventilation not exceeding 1 mm in width 
regardless of the length. 
(b)  The following parts which would contribute 
negligible fuel to a fire: 
Enclosure, PCB, bobbin 
 
 
<12014238 001 > 
 
 
Page 53 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
small mechanical parts, the mass of which 
does not exceed 4 g, such as mounting 
parts, gears, cams, belts and bearings; 
small electrical components, such as 
capacitors with a volume not exceeding 
1750 mm
3
, integrated circuits, transistors and 
optocoupler packages, if these components 
are mounted on material flammability 
category FV-1 or better according to AS/NZS 
4695.707 
NOTE - In considering how to minimize 
propagation of fire and what “small parts” are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part to 
another. 
Compliance is checked by tests of 4.7.201.2, 
4.7.201.3, 4.7.201.4 and 4.7.201.5. 
For the base materials of printed boards, 
compliance is checked by the test of 4.7.201.5. 
The tests shall be carried out on parts of non-
metallic material, which have been removed from 
the apparatus. When the glow-wire test is carried 
out, the parts shall be placed in the same 
orientation, as they would be in normal use. 
These tests are not carried out on internal wiring. 
4.7.201.2 
Parts of non-metallic material are subjected to 
glow wire test of AS/NZS 4695.2.11, which is 
carried out at 550 °C. 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall be not carried out on parts of 
materials classified at least FH-3 according to 
ISO 9772 provided that the sample was not 
thicker than the relevant part. 
Enclosure 
4.7.201.3 
Testing of insulating materials 
Parts of insulating materials supporting potential 
ignition sources shall be subject to the glow-wire 
test of AN/NZS 4695.2.11, which is carried out at 
750 °C. 
The test shall be also carried out on other parts of 
insulating material which are within a distance of 
3 mm of the connection. 
NOTE - Contacts in components such as switch 
contacts are considered to be connections. 
PCB, bobbin 
 
 
<12014238 001 > 
 
 
Page 54 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
For parts, which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle-flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test shall not be tested. 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
5 Severities 
Replace with: 
The duration of application of the test flame shall 
be 30 s ± 1 s. 
 
8 Test procedure 
8.2 Modification: 
Replace the first sentence with: 
The specimen shall be arranged so that the flame 
can be applied to a vertical or horizontal edge as 
shown in the examples of figure 1. 
8.4 Modification: 
The first paragraph does not apply. 
Addition: 
If possible, the flame shall be applied at least 
10 mm from a corner. 
8.5 Replacement: 
The test shall be made on one specimen. If the 
specimen does not withstand the test, the test 
may be repeated on two further specimens, both 
of which shall then withstand the test. 
 
10 Evaluation of test results 
Replace with: 
The duration of burning (t
b
) shall not exceed 30 s. 
However, for printed circuit boards, it shall not 
exceed 15 s. 
The needle-flame test shall not be carried out on 
parts of material classified as V-0 or V-1 
according to IEC 60695-11-10, provided that the 
sample tested was not thicker than the relevant 
part. 
 
 
<12014238 001 > 
 
 
Page 55 of 77 
 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005  
 
4.7.201.4 
Testing in the event of non-extinguishing material 
If parts, other than enclosures, do not withstand 
the glow-wire tests of 4.7.201.3, by failure to 
extinguish within 30 s after the removal of the 
glow-wire tip, the needle-flame test detailed in 
4.7.201.3 is made on all parts of non-metallic 
material which are within a distance of 50 mm or 
which are likely to be impinged upon by flame 
during the tests of 4.7.201.3. Parts shielded by a 
separate barrier which meets the needle-flame 
test need not to be tested. 
NOTE 1 - If the enclosure does not withstand the 
glow-wire test the equipment is considered to 
have failed to meet the requirement of clause 
4.7.201 without the need for consequential 
testing. 
NOTE 2 - If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if 
this indicates that burring or glowing particles can 
fall onto an external surface underneath the 
equipment, the equipment is considered to have 
failed to meet the requirement of clause 4.7.201 
without the need for consequential testing. 
NOTE 3 - Parts likely to be impinged upon by the 
flame are considered to be those within the 
envelope of a vertical cylinder having a radius of 
10 mm and a height equal to the height of the 
flame, positioned above the point of the material 
supporting in contact with or in close proximity to 
connections. 
Added.  
N/A 
4.7.201.5 
Testing of printed boards 
The base material of printed boards is subjected 
to needle-flame test to Clause 4.7.201.3. The 
flame is applied to the edge of the board where 
the heat sink effect is lowest when the board is 
positioned as in normal use. The flame shall not 
be applied to an edge, consisting of broken 
perforations, unless the edge is less than 3 mm 
for a potential ignition source. 
The test is not carried out if the – 
-  Printed board does not carry any potential 
ignition source; 
-  Base material of printed boards, on which the 
available apparent power at a connection 
exceeds 15 VA operating at a voltage 
exceeding 50 V and equal or less than 400 V 
(peak) a.c. or d.c. under normal operating 
conditions, is of flammability category FV-1 or 
better according to AS/NZS 4695.707, or the 
printed boards are protected by an enclosure 
Added.  
N/A 
Page of 78
Display