JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate ▷ View online
<12014238 001 >
Page 48 of 77
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Note(s): --
5.3
TABLE: fault condition tests
P
ambient temperature (°C) ................................. : 25°C if not specified
model/type of power supply .............................. : --
manufacturer of power supply .......................... : Dee Van
rated markings of power supply ....................... : See model list
No.
Component no.
Fault
Test
voltage (V)
Test
time
Fuse
no.
Fuse
current (A)
Result
Model DSA-20R-12 FEU 150204
1
D1
s-c
264
1 s
F1
--
F1 opened immediately, no
hazards.
hazards.
2
C1
s-c
264
1 s
F1
--
F1 opened immediately, no
hazards.
hazards.
3
C2
s-c
264
1 s
F1
--
F1 opened immediately, no
hazards.
hazards.
4
C4
s-c
264
5 min
F1
0.02
Unit shutdown immediately, no
hazards.
hazards.
5
D5
s-c
264
30 min
F1
0.23
Unit work normally, no hazards.
6
Q1 pin D-S
s-c
264
1 s
F1
--
F1 opened immediately, D1,
Q1 damaged, no hazards.
Q1 damaged, no hazards.
7
Q1 pin D-G
s-c
264
1 s
F1
--
F1 opened immediately, D1,
Q1, R11 damaged, no hazards.
Q1, R11 damaged, no hazards.
8
Q1 pin G-S
s-c
264
5 min
F1
0.01
Unit shut down immediately, no
hazards.
hazards.
9
Z1
s-c
264
5 min
F1
0.01
Unit shut down immediately, no
hazards.
hazards.
10
C5
s-c
264
5 min
F1
0.01
Unit shut down immediately, no
hazards.
hazards.
11
Z3
s-c
264
30 min
F1
0.22
Unit work normally, no hazards.
12
D6
s-c
264
6 h
F1
0.31
Steady state reached, the max
temp of T1 coil reached 103°C,
no hazards.
temp of T1 coil reached 103°C,
no hazards.
13
D7
s-c
264
5 min
F1
0.23
Unit shut down immediately, no
hazards.
hazards.
14
C8
s-c
264
1 s
F1
--
F1 opened immediately, Q1
damaged, no hazards.
damaged, no hazards.
15
C9
s-c
264
30 min
F1
0.23
Unit work normally, no hazards.
16
T1 pin 4-5
s-c
264
5 min
F1
0.01
Unit shutdown immediately, no
hazards.
hazards.
17
T1 pin 8-10
s-c
264
1 s
F1
--
F1 opened immediately, Q1
damaged, no hazards.
damaged, no hazards.
<12014238 001 >
Page 49 of 77
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
18
U1 pin 1-2
s-c
264
2 h
F1
0.28
Steady state reached, the max
temp of T1 coil reached 94°C,
no hazards.
temp of T1 coil reached 94°C,
no hazards.
19
U1 pin 1
o-c
264
2 h
F1
0.27
Steady state reached, the max
temp of T1 coil reached 88°C,
no hazards.
temp of T1 coil reached 88°C,
no hazards.
20
U1 pin 3-4
s-c
264
5 min
F1
0.02
Unit shutdown immediately, no
hazards.
hazards.
21
U1 pin 4
o-c
264
2 h
F1
0.27
Steady state reached, the max
temp of T1 coil reached 93°C,
no hazards.
temp of T1 coil reached 93°C,
no hazards.
22
D9
s-c
264
1 s
F1
--
F1 opened immediately, Q1
damaged, no hazards.
damaged, no hazards.
23
C10
s-c
264
5 min
F1
0.23
Unit work normally, no hazards.
24
Output
o-l
264
1.5 h
F1
0.26
The output overload to 1.67A,
T1 coil = 91°C, core = 84°C at
ambient temperature 39.6°C, no
hazards.
T1 coil = 91°C, core = 84°C at
ambient temperature 39.6°C, no
hazards.
25
Output
s-c
264
5 min
F1
0.02
Unit shut down immediately, no
hazards.
hazards.
Model DSA-20R-12 FEU 102204
26
Output
o-l
264
1.5 h
F1
0.27
The output overload to 2.30A,
T1 coil = 83°C, core = 86°C at
ambient temperature 39.6°C, no
hazards.
T1 coil = 83°C, core = 86°C at
ambient temperature 39.6°C, no
hazards.
27
Output
s-c
264
5 min
F1
0.01
Unit shut down immediately, no
hazards.
hazards.
Note(s): - In fault column, where s-c=short-circuited, o-l= over-loaded, o-c= open-circuited.
C.2
Safety isolation transformer
P
Construction details:
Transformer part name: T1
Manufacturer: see table 1.5.1
Type:
see table 1.5.1
Recurring peak voltage
548 Vpeak
Required clearance for reinforced
insulation (from table 2H and 2J)
4.4 mm
Effective voltage rms
260 Vrms
Required creepage distance for reinforced
insulation (from table 2L)
6.0 mm
<12014238 001 >
Page 50 of 77
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Measured min. creepage distance
Location
inside (mm)
outside (mm)
prim-sec
6.4
8.6
core-sec
3.2
4.3
prim-core
3.2
4.3
Measured min. clearances
prim-sec
6.4
8.6
core-sec
3.2
4.3
prim-core
3.2
4.3
Construction:
Concentric windings on EF25 size bobbin. 3 layers of insulation tape between primary (enamelled copper
wire) and secondary windings, 2 layers on outer winding. Winding ends additionally fixed with tape, outer
winding is primary. Teflon tube is provided on primary and secondary winding exit. Margin tape of 3.0 mm
provided on both sides of primary and secondary winding. 2 layers of insulation tape were wrapped on
outside of transformer.
wire) and secondary windings, 2 layers on outer winding. Winding ends additionally fixed with tape, outer
winding is primary. Teflon tube is provided on primary and secondary winding exit. Margin tape of 3.0 mm
provided on both sides of primary and secondary winding. 2 layers of insulation tape were wrapped on
outside of transformer.
Pin numbers
Prim.
1→2; 4→5
Sec.
8→10
Bobbin
Material
Chang Chun Plastics, Phenolic, type T373J,
T375J;
Sumitomo, Phenolic, Type PM-9820
T375J;
Sumitomo, Phenolic, Type PM-9820
Thickness
0.8 mm
Electric strength test
With AC 3000V after humidity treatment
Result
Pass
<12014238 001 >
Page 51 of 77
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Australian National Differences according to CB Bulletin No. CB Bulletin No. 109A, December 2005
APPENDIX Australian National Differences according to CB Bulletin No. 109A, December
2005 (AS/NZS 60950.1:2003)
(IEC Publication 60950-1:2001)
P
EXPLANATION FOR ABBREVIATIONS
P=Pass, F=Fail, N=Not applicable. Placed in the column to the right.
Annex ZZ Variations
Between the definitions for "Person, service" and
"Range, rated frequency" insert the following:
"Range, rated frequency" insert the following:
1.2
Potential ignition source
1.2.12.201
Inserted.
P
1.2.12.15
After the definition of 1.2.12.15, add the following:
1.2.12.201 Potential ignition source:
Possible fault which can start a fire if the open-
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s. current under
normal operating conditions exceeds 15 VA.
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s. current under
normal operating conditions exceeds 15 VA.
Such a faulty contact or interruption in an
electrical connection includes those which may
occur in conductive patterns on printed boards.
electrical connection includes those which may
occur in conductive patterns on printed boards.
NOTE 201: An electronic protection circuit may be
used to prevent such a fault from becoming a
potential ignition source.
used to prevent such a fault from becoming a
potential ignition source.
NOTE 202: This definition is from AS/NZS
60065:2003.
60065:2003.
Added.
P
1.5.1
Add the following to the end of first paragraph:
"or the relevant Australian/New Zealand
Standard."
Standard."
Added.
P
1.5.2
Add the following to the end of first and third dash
items:
items:
"or the relevant Australian/New Zealand
Standard."
Standard."
Added and see appendix II for
plug test report.
plug test report.
P
2.1
Delete the Note.
Deleted
P
3.2.3
Delete Note 2.
Deleted
N/A
Modify Table 3B as follows:
Rated current of
equipment A
Nominal
cross-
sectional
area mm
2
AWG or kcmil
(cross-sectional
area in mm
2
)
see note 2
3.2.5
Over 0.2 up to
and including 3
and including 3
0.5
1)
18 [0.8]
Replaced.
N/A