<12014238 001 > 
 
 
Page 28 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
ANNEX W, SUMMATION OF TOUCH CURRENTS  
W.1 
Touch current from electronic circuits 
See table 5.1.6 
W.1.2 
Earthed circuits 
 
N/A 
W.2 
Interconnection of several equipments 
 
N/A 
W.2.1 
Isolation 
 
N/A 
W.2.2 
Common return, isolated from earth 
 
N/A 
W.2.3 
Common return, connected to protective earth 
 
N/A 
 
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS 
(see clause C.1) 
N/A 
X.1 
Determination of maximum input current  
 
N/A 
X.2 
Overload test procedure 
 
N/A 
 
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) 
N/A 
Y.1 
Test apparatus .....................................................:   
N/A 
Y.2 
Mounting of test samples .....................................:   
N/A 
Y.3 
Carbon-arc light-exposure apparatus  ..................:   
N/A 
Y.4 
Xenon-arc light exposure apparatus ....................:   
N/A 
 
 
<12014238 001 > 
 
 
Page 29 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
EU Group Differences [C],  
EU Special National Conditions [S], EU A-Deviations [A] 
(EN 60950-1:2001, Annex ZB and Annex ZC) 
General 
C: Delete all the "country" notes in the reference 
document according to the following list: 
1.1.5  
Note 2 
1.5.8 
Note 2 
1.6.1 
Note  
1.7.2 
Note 4 
1.7.12 
Note 2 
2.6 
Note 
2.2.3 
Note 
2.2.4 
Note 
2.3.2 
Note 2, 7, 8 
2.3.3 
Note 1, 2 
2.3.4 
Note 2,3  2.7.1 
Note 
2.10.3.1 Note 4 
3.2.1.1 
Note 
3.2.3 
Note 1, 2 
3.2.5.1  Note 2 
4.3.6 
Note 1,2  4.7.2.2  Note 
4.7.3.1  Note 2 
6.1.2.1 
Note 
6.1.2.2  Note 
6.2.2 
Note 
6.2.2.1 
Note 2 
6.2.2.2  Note 
Note 4 
7.1 
Note 
 
G2.1 
Note 1, 2 
Annex H  Note 2 
Deleted 
N/A 
1.2.4.1 
S (DK): Certain types of Class I appliances (see 
3.2.1.1) may be provided with a plug not 
establishing earthing conditions when inserted 
into Danish socket-outlets. 
Class II equipment. 
N/A 
1.5.1 
A (SE, Ordinance 1990:944 and  
CH, Ordinance on environmentally hazardous 
substances SR 814.013, Annex 3.2, Mercury): 
Add 
NOTE – Switches containing mercury such as 
thermostats, relays and level controllers are not allowed.
 
No switch. 
N/A 
1.5.8 
S (NO): Due to the IT power system used (see 
annex V, Fig. V.7), capacitors are required to be 
rated for the applicable line-to-line voltage 
(230 V). 
Class II equipment. 
N/A 
1.7.2 
S (FI, NO, SE): 
 CLASS I PLUGGABLE EQUIPMENT 
TYPE A  
intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
Class II equipment. 
N/A 
 
FI: "Laite on liitettävä suojamaadoituskoskettimilla 
varustettuun pistorasiaan" 
Class II equipment. 
N/A 
 
NO: "Apparatet må tilkoples jordet stikkontakt" 
Class II equipment. 
N/A 
 
SE: "Apparaten skall anslutas till jordat uttag" 
Class II equipment. 
N/A 
 
A (DK, Heavy Current Regulations): Supply cords 
of class I equipment, which is delivered without a 
plug, must be provided with a visible tag with the 
following text: 
Vigtigt! 
Lederen med grøn/gul isolation må kun tilsluttes 
en klemme mærket 
 
 eller  
  
If essential for the safety of the equipment, the 
Class II equipment 
N/A 
 
 
<12014238 001 > 
 
 
Page 30 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
tag must in addition be provided with a diagram 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende instalationsvejledning." 
1.7.5 
S (DK): Socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For stationary 
equipment the socket-outlet shall be in accor-
dance with Standard Sheet DK 1-1b or DK 1-5a. 
No socket-outlet. 
N/A 
1.7.5 
A (DK, Heavy Current Regulations): 
CLASS
 
II
 
EQUIPMENT
 shall not be fitted with socket-
outlets for providing power to other equipment. 
No socket outlet. 
N/A 
1.7.12 
A (DE, Gesetz über technische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on 
the execution of the Second Section of the 
Equipment safety law], of 10
th
 January 1996, 
article 2, 4
th
 paragraph item 2): 
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even only by service 
personnel are not exempted.  
"Operation instruction" provided 
in German language. 
1.7.15 
A (CH, Ordinance on environmentally hazardous 
substances SR 814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
No batteries. 
N/A 
 
A (DE, Regulation on protection against hazards 
by X-ray, of 8
th
 January 1987, Article 5 [Operation 
of X-ray emission source], clauses 1 to 4): 
a) A licence is required by those who operate an 
X-ray emission source. 
b) A licence in accordance with Cl. 1 is not 
required by those who operate an X-ray emission 
source on which the electron acceleration voltage 
does not exceed 20 kV if 
1) the local dose rate at a distance of 0,1 m from 
the surface does not exceed 1 µSv/h and 
2) it is adequately indicated on the X-ray emission 
source that 
i)  X-rays are generated and 
ii)  the electron acceleration voltage must not 
exceed the maximum value stipulated by 
No radiation. 
N/A 
 
 
<12014238 001 > 
 
 
Page 31 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
the manufacturer or importer. 
c) A licence in accordance with Cl. 1 is also not 
required by persons who operate an X-ray 
emission source on which the electron 
acceleration voltage exceeds 20 kV if 
1) the X-ray emission source has been granted a 
type approval and 
2) it is adequately indicated on the X-ray emission 
source that 
i)  X-rays are generated 
ii) the device stipulated by the manufacturer or 
importer guarantees that the maximum 
permissible local dose rate in accordance 
with the type approval is not exceeded and 
iii) the electron acceleration voltage must not 
exceed the maximum value stipulated by the 
manufacturer or importer. 
d) Furthermore, a licence in accordance with 
Cl. 1 is also not required by persons who operate 
X-ray emission sources on which the electron 
acceleration voltage does not exceed 30 kV if 
1) the X-rays are generated only by intrinsically 
safe CRTs complying with Enclosure III, No. 6, 
2) the values stipulated in accordance with 
Enclosure III, No. 6.2 are limited by technical 
measures and specified in the device and 
3) it is adequately indicated on the X-ray emission 
source that the X-rays generated are ade-
quately screened by the intrinsically safe CRT. 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
Not TNV 
N/A 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
Not TNV 
N/A 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
Not TNV 
N/A 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Class II equipment 
N/A 
2.7.1 
C: Replace the subclause as follows: 
Basic requirements
 
To protect against excessive current, short-
circuits and earth faults in 
PRIMARY CIRCUITS
protective devices shall be included either as 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), b) 
and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as parts of 
the equipment; 
Replaced. 