<12014238 001 > 
 
 
Page 16 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
Number of conductors, diameter (mm) of cable 
and conduits  ........................................................: 
 
 
3.2.4 
Appliance inlets 
Direct plug-in equipment. 
N/A 
3.2.5 
Power supply cords  
No power cord. 
N/A 
3.2.5.1 
AC power supply cords 
 
N/A 
 
Type ......................................................................:   
 
 
Rated current (A), cross-sectional area (mm2),  
AWG .....................................................................: 
 
 
3.2.5.2 
DC power supply cords 
AC Source. 
N/A 
3.2.6 
Cord anchorages and strain relief 
No power cord. 
N/A 
 
Mass of equipment (kg), pull (N)   ........................:   
 
 
Longitudinal displacement (mm) ..........................:   
 
3.2.7 
Protection against mechanical damage 
No parts under this unit likely to 
damage the power supply cord. 
No sharp edges. 
3.2.8 
Cord guards 
No cord guard provided. 
N/A 
 
D (mm); test mass (g) ..........................................:   
 
 
Radius of curvature of cord (mm).........................:   
 
3.2.9 
Supply wiring space 
Not permanent connection or 
non-detachable power cord 
type. 
N/A 
 
3.3 
Wiring terminals for connection of external conductors 
N/A 
3.3.1 
Wiring terminals 
Direct plug-in equipment. 
N/A 
3.3.2 
Connection of non-detachable power supply 
cords 
 
N/A 
3.3.3 
Screw terminals 
 
N/A 
3.3.4 
Conductor sizes to be connected 
 
N/A 
 
Rated current (A), cord/cable type, cross-sectional 
area (mm2) ...........................................................: 
 
 
3.3.5 
Wiring terminal sizes 
 
N/A 
 
Rated current (A), type and nominal thread 
diameter (mm)  .....................................................: 
 
 
3.3.6 
Wiring terminals design 
 
N/A 
3.3.7 
Grouping of wiring terminals 
 
N/A 
3.3.8 
Stranded wire 
 
N/A 
 
 
 
 
3.4 
Disconnection from the mains supply 
3.4.1 
General requirement 
Disconnect device provided. 
 
 
<12014238 001 > 
 
 
Page 17 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
3.4.2 
Disconnect devices 
Plug of this direct plug-in 
equipment was used as 
disconnected device. 
3.4.3 
Permanently connected equipment 
Not permanently connected 
equipment. 
N/A 
3.4.4 
Parts which remain energized 
There is no parts remained with 
hazardous voltage or energy in 
the equipment when SPS is 
separated from AC mains. 
3.4.5 
Switches in flexible cords 
No flexible cords. 
N/A 
3.4.6 
Single-phase equipment and d.c. equipment 
The mains plug disconnects 
both poles simultaneously. 
3.4.7 
Three-phase equipment 
Single phase equipment. 
N/A 
3.4.8 
Switches as disconnect devices 
See sub-clause 3.4.2. 
N/A 
3.4.9 
Plugs as disconnect devices 
See sub-clause 3.4.2. 
N/A 
3.4.10 
Interconnected equipment 
No interconnections using 
hazardous voltages. 
N/A 
3.4.11 
Multiple power sources 
Only one supply connection 
provided. 
N/A 
 
3.5 
Interconnection of equipment 
3.5.1 
General requirements 
This power supply is not 
considered for connection to 
TNV. 
3.5.2 
Types of interconnection circuits ..........................:  Interconnection circuits of 
SELV through the connector. 
No ELV interconnection 
circuits. 
3.5.3 
ELV circuits as interconnection circuits  
No ELV interconnection 
N/A 
 
PHYSICAL REQUIREMENTS 
4.1 
Stability 
N/A 
 
Angle of 10° 
Direct plug-in equipment. 
N/A 
 
Test: force (N).......................................................:   
N/A 
 
 
 
 
4.2 
Mechanical strength 
4.2.1 
General 
See below. After tests, unit 
comply with 2.1.1, 2.6.1, 2.10 
and 4.4.1. 
4.2.2 
Steady force test, 10 N 
10N applied to components 
other than parts serving as an 
enclosure. 
 
 
<12014238 001 > 
 
 
Page 18 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
4.2.3 
Steady force test, 30 N 
No internal enclosure. 
N/A 
4.2.4 
Steady force test, 250 N 
250N applied to outer 
enclosure. No energy or other 
hazards. 
4.2.5 
Impact test 
Direct plug-in equipment. 
N/A 
 
Fall test 
 
N/A 
 
Swing test 
 
N/A 
4.2.6 
Drop test 
No hazard as result from drop 
test. 
4.2.7 
Stress relief test 
After 7 hours at temperature of 
75°C and cooling down to room 
temperature, no shrinkage, 
distortion or loosening any 
enclosure part was noticeable 
on the adapter. 
Test was performed for all 
sources of enclosure material. 
4.2.8 
Cathode ray tubes 
No CRT provided. 
N/A 
 
Picture tube separately certified ...........................:   
N/A 
4.2.9 
High pressure lamps 
No High pressure lamps 
provided. 
N/A 
4.2.10 
Wall or ceiling mounted equipment; force (N)  .....:  Direct plug-in equipment. 
N/A 
 
4.3 
Design and construction  
4.3.1 
Edges and corners 
All edges and corners are 
rounded and /or smoothed. 
4.3.2 
Handles and manual controls; force (N) ...............:  No handles or controls provided. 
N/A 
4.3.3 
Adjustable controls  
No controls provided. 
N/A 
4.3.4 
Securing of parts 
No connection likely to be 
exposed to mechanical stress is 
provided in unit. 
4.3.5 
Connection of plugs and sockets 
No mismating of connectors, 
plugs or sockets possible.  
4.3.6 
Direct plug-in equipment 
The prevention of imposing to 
undue strain on the socket-
outlet was done by construction 
of the plug of adaptor. 
For British plug: 0.07Nm; 
For Australian plug: 0.08Nm; 
For Japan plug: 0.07Nm. 
 
 
<12014238 001 > 
 
 
Page 19 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
Dimensions (mm) of mains plug for direct plug-in :  (See attached partial test 
reports) 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) ................................: 
See above. 
4.3.7 
Heating elements in earthed equipment 
No heating elements provided. 
N/A 
4.3.8 
Batteries 
No batteries provided. 
N/A 
4.3.9 
Oil and grease 
No heating elements provided. 
N/A 
4.3.10 
Dust, powders, liquids and gases 
Equipment in intended use not 
considered to be exposed to 
these. 
N/A 
4.3.11 
Containers for liquids or gases 
No container for liquid or gas. 
N/A 
4.3.12 
Flammable liquids.................................................:  No such flammable liquid. 
N/A 
 
Quantity of liquid (l) ...............................................:   
N/A 
 
Flash point (°C).....................................................:   
N/A 
4.3.13 
Radiation; type of radiation  ..................................:  No optical radiation present. 
N/A 
4.3.13.1 
General 
 
N/A 
4.3.13.2 
Ionizing radiation  
 
N/A 
 
Measured radiation (pA/kg)  .................................:   
 
 
Measured high-voltage (kV)  ................................:   
 
 
Measured focus voltage (kV) ...............................:   
 
 
CRT markings  .....................................................:   
 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A 
 
Part, property, retention after test, flammability 
classification  ........................................................: 
 
N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation ......:   
N/A 
4.3.13.5 
Laser (including LEDs) 
No optical radiation present. 
N/A 
 
Laser class ...........................................................:   
 
4.3.13.6 
Other types  ..........................................................:   
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 
General 
No moving parts. 
N/A 
4.4.2 
Protection in operator access areas 
 
N/A 
4.4.3 
Protection in restricted access locations  
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
 
 
 
 
4.5 
Thermal requirements 
4.5.1 
Maximum temperatures 
See appended table 4.5.1. 