JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate ▷ View online
<12014238 001 >
Page 8 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
1.7.7.2
Terminal for a.c. mains supply conductors
Direct plug-in equipment.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
No d.c. mains supply.
N/A
1.7.8
Controls and indicators
No safety related switches or
indicators.
indicators.
N/A
1.7.8.1
Identification, location and marking .....................:
N/A
1.7.8.2
Colours ...............................................................:
N/A
1.7.8.3
Symbols according to IEC 60417 .........................:
N/A
1.7.8.4
Markings using figures ........................................:
N/A
1.7.9
Isolation of multiple power sources .....................: Only one supply from the
mains.
N/A
1.7.10
IT power distribution systems
Only for Norway
P
1.7.11
Thermostats and other regulating devices
No such device.
N/A
1.7.12
Language(s) .........................................................: Installation instruction in
English and German.
Versions in other languages
have to be provided during the
corresponding national
approvals.
have to be provided during the
corresponding national
approvals.
1.7.13
Durability
The label was subjected to the
permanence of marking test.
The label was rubbed with cloth
soaked with water for 15 sec.
And then again for 15 sec. With
the cloth soaked with
petroleum spirit.
After this test there was no
damage to the label. The
marking on the label did not
fade. There was no curling nor
lifting of the label edge.
permanence of marking test.
The label was rubbed with cloth
soaked with water for 15 sec.
And then again for 15 sec. With
the cloth soaked with
petroleum spirit.
After this test there was no
damage to the label. The
marking on the label did not
fade. There was no curling nor
lifting of the label edge.
P
1.7.14
Removable parts
No removable part.
N/A
1.7.15
Replaceable batteries
No battery provided.
N/A
Language(s)..........................................................:
1.7.16
Operator access with a tool ..................................: No operator accessible area
that needs to be accessed by
the use of a tool.
the use of a tool.
N/A
1.7.17
Equipment for restricted access locations ............: Not limited for use in restricted
access locations.
N/A
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
<12014238 001 >
Page 9 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
2.1.1
Protection in operator access areas
No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage.
test pin to any parts with only
basic insulation to ELV or
hazardous voltage.
P
2.1.1.1
Access to energized parts
See above.
P
Test by inspection ................................................: See above.
P
Test with test finger ..............................................: See above.
P
Test with test pin ..................................................: See above.
P
Test with test probe .............................................: No TNV.
N/A
2.1.1.2
Battery compartments .........................................: No battery compartment.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance (mm) through insulation
distance (mm) through insulation
(see appended table 2.10.5)
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
operator accessible area.
N/A
2.1.1.5
Energy hazards ....................................................: Energy does not exceed 240VA
between any two points in
accessible parts (o/p connector
of secondary circuit). Results
see appended table 2.1.1.5. No
energy hazard in operator
access area.
accessible parts (o/p connector
of secondary circuit). Results
see appended table 2.1.1.5. No
energy hazard in operator
access area.
P
2.1.1.6
Manual controls
No manual controls.
N/A
2.1.1.7
Discharge of capacitors in equipment
There is no capacitor connected
to the mains circuit.
to the mains circuit.
N/A
Time-constant (s); measured voltage (V) .............:
2.1.2
Protection in service access areas
No operator accessible area
that needs to be accessed by
the use of a tool.
that needs to be accessed by
the use of a tool.
N/A
2.1.3
Protection in restricted access locations
Not limited for use in restricted
access locations.
access locations.
N/A
2.2
SELV circuits
P
2.2.1
General requirements
The secondary circuits were
tested as SELV. See 2.2.1 to
2.2.4.
tested as SELV. See 2.2.1 to
2.2.4.
P
2.2.2
Voltages under normal conditions (V) ..................: Between any conductor of the
SELV circuits 42.4 V peak or
60 V d.c. are not exceeded.
60 V d.c. are not exceeded.
See appended table 2.2.2.
P
<12014238 001 >
Page 10 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
2.2.3
Voltages under fault conditions (V).......................: Single fault did not cause
excessive voltage in accessible
SELV circuits. Limits of 71V
peak and 120V d.c. were not
exceeded within 0.2 seconds
and limits 42.4V peak and 60V
d.c. were not exceeded for
longer than 0.2 seconds.
SELV circuits. Limits of 71V
peak and 120V d.c. were not
exceeded within 0.2 seconds
and limits 42.4V peak and 60V
d.c. were not exceeded for
longer than 0.2 seconds.
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
Double or reinforced for the
highest working voltage across
a particular insulation is
provided.
highest working voltage across
a particular insulation is
provided.
P
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits........: See 2.2.2 and 2.2.3.
P
2.3
TNV circuits
N/A
2.3.1
Limits
No TNV.
N/A
Type of TNV circuits .............................................:
2.3.2
Separation from other circuits and from accessible
parts
parts
N/A
Insulation employed ..............................................:
2.3.3
Separation from hazardous voltages
N/A
Insulation employed ..............................................:
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation employed ..............................................:
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
N/A
2.4.1
General requirements
N/A
2.4.2
Limit values
N/A
Frequency (Hz) .....................................................:
Measured current (mA).........................................:
Measured voltage (V) ...........................................:
Measured capacitance (µF) ..................................:
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5
Limited power sources
P
<12014238 001 >
Page 11 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Inherently limited output
N/A
Impedance limited output
N/A
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
(See appended table)
P
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
power (VA)............................................................:
power (VA)............................................................:
(See appended table)
Current rating of overcurrent protective device (A)
2.6
Provisions for earthing and bonding
P
2.6.1
Protective earthing
Class II equipment.
N/A
2.6.2
Functional earthing
Secondary functional ground
separated to primary by
reinforced or double insulation.
separated to primary by
reinforced or double insulation.
P
2.6.3
Protective earthing and protective bonding
conductors
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Rated current (A), cross-sectional area (mm2),
AWG .....................................................................:
AWG .....................................................................:
2.6.3.3
Size of protective bonding conductors
N/A
Rated current (A), cross-sectional area (mm2),
AWG .....................................................................:
AWG .....................................................................:
2.6.3.4
Resistance (Ω) of earthing conductors and their
terminations, test current (A) ................................:
terminations, test current (A) ................................:
N/A
2.6.3.5
Colour of insulation ...............................................:
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type and nominal thread
diameter (mm) ......................................................:
diameter (mm) ......................................................:
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors
and protective bonding conductors
and protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A