JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12014238 001 > 
 
 
Page 8 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
1.7.7.2 
Terminal for a.c. mains supply conductors  
Direct plug-in equipment. 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
No d.c. mains supply. 
N/A 
1.7.8 
Controls and indicators 
No safety related switches or 
indicators. 
N/A 
1.7.8.1 
Identification, location and marking  .....................:   
N/A 
1.7.8.2 
Colours   ...............................................................:   
N/A 
1.7.8.3 
Symbols according to IEC 60417 .........................:   
N/A 
1.7.8.4 
Markings using figures  ........................................:   
N/A 
1.7.9 
Isolation of multiple power sources  .....................:  Only one supply from the 
mains. 
N/A 
1.7.10 
IT power distribution systems  
Only for Norway 
1.7.11 
Thermostats and other regulating devices  
No such device. 
N/A 
1.7.12 
Language(s) .........................................................:  Installation instruction in 
English and German. 
Versions in other languages 
have to be provided during the 
corresponding national 
approvals. 
 
1.7.13 
Durability 
The label was subjected to the 
permanence of marking test. 
The label was rubbed with cloth 
soaked with water for 15 sec. 
And then again for 15 sec. With 
the cloth soaked with 
petroleum spirit. 
After this test there was no 
damage to the label. The 
marking on the label did not 
fade. There was no curling nor 
lifting of the label edge. 
1.7.14 
Removable parts 
No removable part. 
N/A 
1.7.15 
Replaceable batteries 
No battery provided. 
N/A 
 
Language(s)..........................................................:   
 
1.7.16 
Operator access with a tool ..................................:  No operator accessible area 
that needs to be accessed by 
the use of a tool. 
N/A 
1.7.17 
Equipment for restricted access locations ............:  Not limited for use in restricted 
access locations. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
 
 
<12014238 001 > 
 
 
Page 9 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
2.1.1 
Protection in operator access areas  
No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. 
2.1.1.1 
Access to energized parts 
See above. 
 
Test by inspection ................................................:  See above. 
 
Test with test finger ..............................................:  See above. 
 
Test with test pin ..................................................:  See above. 
 
Test with test probe  .............................................:  No TNV. 
N/A 
2.1.1.2 
Battery compartments  .........................................:  No battery compartment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance (mm) through insulation 
(see appended table 2.10.5) 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
N/A 
2.1.1.5 
Energy hazards ....................................................:  Energy does not exceed 240VA 
between any two points in 
accessible parts (o/p connector 
of secondary circuit). Results 
see appended table 2.1.1.5. No 
energy hazard in operator 
access area. 
2.1.1.6 
Manual controls 
No manual controls. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
There is no capacitor connected 
to the mains circuit. 
N/A 
 
Time-constant (s); measured voltage (V) .............:   
 
2.1.2 
Protection in service access areas 
No operator accessible area 
that needs to be accessed by 
the use of a tool. 
N/A 
2.1.3 
Protection in restricted access locations 
Not limited for use in restricted 
access locations. 
N/A 
 
2.2 
SELV circuits 
2.2.1 
General requirements 
The secondary circuits were 
tested as SELV. See 2.2.1 to 
2.2.4. 
2.2.2 
Voltages under normal conditions (V) ..................:  Between any conductor of the 
SELV circuits 42.4 V peak or 
60 V d.c. are not exceeded.      
See appended table 2.2.2. 
 
 
<12014238 001 > 
 
 
Page 10 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
2.2.3 
Voltages under fault conditions (V).......................:  Single fault did not cause 
excessive voltage in accessible 
SELV circuits. Limits of 71V 
peak and 120V d.c. were not 
exceeded within 0.2 seconds 
and limits 42.4V peak and 60V 
d.c. were not exceeded for 
longer than 0.2 seconds. 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
Double or reinforced for the 
highest working voltage across 
a particular insulation is 
provided. 
2.2.3.2 
Separation by earthed screen (method 2) 
 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 
N/A 
2.2.4 
Connection of SELV circuits to other circuits........:  See 2.2.2 and 2.2.3. 
 
2.3 
TNV circuits 
N/A 
2.3.1 
Limits 
No TNV. 
N/A 
 
Type of TNV circuits .............................................:   
 
2.3.2 
Separation from other circuits and from accessible 
parts 
 
N/A 
 
Insulation employed ..............................................:   
 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 
Insulation employed ..............................................:   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 
Insulation employed ..............................................:   
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
2.4 
Limited current circuits 
N/A 
2.4.1 
General requirements 
 
N/A 
2.4.2 
Limit values 
 
N/A 
 
Frequency (Hz) .....................................................:   
 
 
Measured current (mA).........................................:   
 
 
Measured voltage (V) ...........................................:   
 
 
Measured capacitance (µF) ..................................:   
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A 
 
 
 
 
2.5 
Limited power sources 
 
 
<12014238 001 > 
 
 
Page 11 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
Inherently limited output 
 
N/A 
 
Impedance limited output 
 
N/A 
 
Overcurrent protective device limited output 
 
N/A 
 
Regulating network limited output under normal 
operating and single fault condition 
(See appended table) 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
 
N/A 
 
Output voltage (V), output current (A), apparent 
power (VA)............................................................: 
(See appended table) 
 
 
Current rating of overcurrent protective device (A)   
 
 
2.6 
Provisions for earthing and bonding 
2.6.1 
Protective earthing 
Class II equipment. 
N/A 
2.6.2 
Functional earthing 
Secondary functional ground 
separated to primary by 
reinforced or double insulation. 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm2), 
AWG .....................................................................: 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm2), 
AWG .....................................................................: 
 
 
2.6.3.4 
Resistance (Ω) of earthing conductors and their 
terminations, test current (A) ................................: 
 
N/A 
2.6.3.5 
Colour of insulation ...............................................:   
N/A 
2.6.4 
Terminals 
 
N/A 
2.6.4.1 
General 
 
N/A 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 
 
Rated current (A), type and nominal thread 
diameter (mm) ......................................................: 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors 
and protective bonding conductors 
 
N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 