DOWNLOAD JBL ON STAGE III IIIP (serv.man2) Service Manual ↓ Size: 1.55 MB | Pages: 78 in PDF or view online for FREE

Model
ON STAGE III IIIP (serv.man2)
Pages
78
Size
1.55 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-iii-iiip-sm2.pdf
Date

JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12014238 001 > 
 
 
Page 24 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
A.2.1 
Samples, material.................................................:   
 
 
Wall thickness (mm) .............................................:   
 
A.2.2 
Conditioning of samples 
 
N/A 
A.2.3 
Mounting of samples  ...........................................:   
N/A 
A.2.4 
Test flame (see IEC 60695-11-4) 
 
N/A 
 
Flame A, B or C  ...................................................:   
 
A.2.5 
Test procedure 
 
N/A 
A.2.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ....................................:   
 
 
Sample 2 burning time (s) ....................................:   
 
 
Sample 3 burning time (s) ....................................:   
 
A.2.7 
Alternative test acc. To IEC 60695-2-2, cl. 4 and 
 
N/A 
 
Sample 1 burning time (s) ....................................:   
 
 
Sample 2 burning time (s) ....................................:   
 
 
Sample 3 burning time (s) ....................................:   
 
A.3 
Hot flaming oil test (see 4.6.2) 
 
N/A 
A.3.1 
Mounting of samples  
 
N/A 
A.3.2 
Test procedure  
 
N/A 
A.3.3 
Compliance criterion 
 
N/A 
 
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and 
5.3.2) 
N/A 
B.1 
General requirements 
No motor provided. 
N/A 
 
Position  ................................................................:   
 
 
Manufacturer ........................................................:   
 
 
Type  .....................................................................:   
 
 
Rated values  .......................................................:   
 
B.2 
Test conditions 
 
N/A 
B.3 
Maximum temperatures 
 
N/A 
B.4 
Running overload test 
 
N/A 
B.5 
Locked-rotor overload test 
 
N/A 
 
Test duration (days) .............................................:   
 
 
Electric strength test: test voltage (V)  ..................:   
 
B.6 
Running overload test for d.c. motors in 
secondary circuits 
 
N/A 
B.7 
Locked-rotor overload test for d.c. motors in secondary circuits 
N/A 
 
 
<12014238 001 > 
 
 
Page 25 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
B.7.1 
Test procedure  
 
N/A 
B.7.2 
Alternative test procedure; test time (h)................:   
N/A 
B.7.3 
Electric strength test  
 
N/A 
B.8 
Test for motors with capacitors 
 
N/A 
B.9 
Test for three-phase motors 
 
N/A 
B.10 
Test for series motors 
 
N/A 
 
Operating voltage (V) ...........................................:   
 
 
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) 
 
Position  ................................................................:  T1 
 
 
Manufacturer ........................................................:  Dee Van Enterprise Co., Ltd. 
 
 
Type  .....................................................................:  See appended table 1.5.1 
 
 
Rated values  .......................................................:  Class B 
 
 
Method of protection .............................................:  By protection circuit design. 
 
C.1 
Overload test 
See appended table 5.3. 
C.2 
Insulation 
See appended table C.2. 
 
Protection from displacement of windings ............:  By insulation tape 
 
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS 
(see 5.1.4) 
D.1 
Measuring instrument 
 
D.2 
Alternative measuring instrument 
 
N/A 
 
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) 
N/A 
 
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES 
(see 2.10) 
 
 
 
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM 
CLEARANCES  
N/A 
G.1 
Summary of the procedure for determining 
minimum clearances 
 
N/A 
G.2 
Determination of mains transient voltage (V) .......:   
N/A 
G.2.1 
AC mains supply 
 
N/A 
G.2.2 
DC mains supply 
 
N/A 
G.3 
Determination of telecommunication network 
transient voltage (V)..............................................: 
 
N/A 
G.4 
Determination of required withstand voltage (V)...:   
N/A 
 
 
<12014238 001 > 
 
 
Page 26 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
G.5 
Measurement of transient levels (V).....................:   
N/A 
G.6 
Determination of minimum clearances .................:   
N/A 
 
ANNEX H, IONIZING RADIATION (see 4.3.13) 
N/A 
 
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) 
N/A 
 
Metal used  ...........................................................:  No risk of corrosion. 
 
 
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7) 
N/A 
K.1 
Making and breaking capacity 
 
N/A 
K.2  
Thermostat reliability; operating voltage (V) .........:   
N/A 
K.3 
Thermostat endurance test; operating voltage 
(V)   .......................................................................: 
 
N/A 
K.4 
Temperature limiter endurance; operating voltage 
(V)  ........................................................................: 
 
N/A 
K.5 
Thermal cut-out reliability 
 
N/A 
K.6 
Stability of operation 
 
N/A 
 
 
 
 
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL 
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1) 
L.1  
Typewriters 
 
N/A 
L.2 
Adding machines and cash registers 
 
N/A 
L.3 
Erasers 
 
N/A 
L.4 
Pencil sharpeners 
 
N/A 
L.5 
Duplicators and copy machines 
 
N/A 
L.6 
Motor-operated files 
 
N/A 
L.7 
Other business equipment 
 
 
 
 
 
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) 
N/A 
M.1 
Introduction 
No telephone signal. 
N/A 
M.2  
Method A 
 
N/A 
M.3 
Method B 
 
N/A 
M.3.1 
Ringing signal 
 
N/A 
M.3.1.1 
Frequency (Hz)  ....................................................:   
 
M.3.1.2 
Voltage (V) ...........................................................:   
 
M.3.1.3 
Cadence; time (s), voltage (V)  .............................:   
 
M.3.1.4 
Single fault current (mA) .......................................:   
 
 
 
<12014238 001 > 
 
 
Page 27 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
M.3.2 
Tripping device and monitoring voltage ................:   
N/A 
M.3.2.1 
Conditions for use of a tripping device or a 
monitoring voltage 
 
N/A 
M.3.2.2 
Tripping device 
 
N/A 
M.3.2.3 
Monitoring voltage (V)...........................................:   
N/A 
 
ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and 
clause G.5) 
N/A 
N.1 
ITU-T impulse test generators 
 
N/A 
N.2 
IEC 60065 impulse test generator 
 
N/A 
 
ANNEX P, NORMATIVE REFERENCES 
 
ANNEX Q, BIBLIOGRAPHY 
 
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL 
PROGRAMMES 
N/A 
R.1 
Minimum separation distances for unpopulated 
coated printed boards (see 2.10.6) 
 
N/A 
R.2 
Reduced clearances (see 2.10.3) 
 
N/A 
 
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) 
N/A 
S.1 
Test equipment 
 
N/A 
S.2 
Test procedure 
 
N/A 
S.3 
Examples of waveforms during impulse testing 
 
N/A 
 
 
 
 
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER 
(see 1.1.2) 
N/A 
 
 
 
 
 
 
 
 
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED 
INSULATION (see 2.10.5.4) 
N/A 
 
 
 
 
 
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)  
V.1 
Introduction 
 
V.2 
TN power distribution systems  
 
V.3 
TT power systems 
 
N/A 
V.4 
IT power systems 
IT-power system for Norway. 
Page of 78
Display