IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Normal load condition per Annex L.......................: See 1.6.2.
P
4.5.2
Resistance to abnormal heat
See appended table 4.5.2.
P
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No openings
P
Dimensions (mm) ................................................:
4.6.2
Bottoms of fire enclosures
No openings
P
Construction of the bottom ...................................:
4.6.3
Doors or covers in fire enclosures
No such things.
N/A
4.6.4
Openings in transportable equipment
No opening.
N/A
4.6.5
Adhesives for constructional purposes
No adhesive.
N/A
Conditioning temperature (°C)/time (weeks) ........:
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Use of materials with the
required flammability classes.
required flammability classes.
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
(see appended table 4.7)
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
With having the following parts:
▪ Components in primary
▪ Components in secondary
▪ Components having
unenclosed arcing parts at
hazardous voltage or energy
level
hazardous voltage or energy
level
▪ Insulated wiring
The fire enclosure is required.
P
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3
Materials
P
4.7.3.1
General
Parts mounted on PCB of
flammability class V-0 or better.
flammability class V-0 or better.
P
4.7.3.2
Materials for fire enclosures
The fire enclosure is V-1 or
better material.
better material.
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
No part outside fire enclosure.
N/A
<12014238 001 >
Page 21 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
P
4.7.3.5
Materials for air filter assemblies
No air filters provided.
N/A
4.7.3.6
Materials used in high-voltage components
No high voltage components
provided.
provided.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
See sub-clauses 5.1.2 to 5.1.6.
P
5.1.2
Equipment under test (EUT)
EUT has only one mains
connection.
connection.
P
5.1.3
Test circuit
Equipment of figure 5A used.
P
5.1.4
Application of measuring instrument
Using measuring instrument in
annex D.
annex D.
P
5.1.5
Test procedure
The touch current was
measured from mains to DC
output connector and to a 100
mm × 200 mm metal foil
wrapped on accessible non-
conductive parts (plastic
enclosure).
measured from mains to DC
output connector and to a 100
mm × 200 mm metal foil
wrapped on accessible non-
conductive parts (plastic
enclosure).
P
5.1.6
Test measurements
See below.
P
Test voltage (V) ...................................................: See appended table 5.1.6.
Measured touch current (mA) ..............................: See appended table 5.1.6.
Max. allowed touch current (mA) .........................: See appended table 5.1.6.
Measured protective conductor current (mA) ......:
Max. allowed protective conductor current (mA) .:
5.1.7
Equipment with touch current exceeding 3.5 mA : Neither stationary permanently
connected equipment nor
stationary pluggable equipment
type B.
stationary pluggable equipment
type B.
N/A
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and from
telecommunication networks
networks and cable distribution systems and from
telecommunication networks
No TNV.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
telecommunication network and a cable
distribution system
N/A
Test voltage (V) ...................................................:
Measured touch current (mA) ..............................:
Max. allowed touch current (mA) .........................:
5.1.8.2
Summation of touch currents from
telecommunication networks ................................:
telecommunication networks ................................:
N/A
<12014238 001 >
Page 22 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
5.2
Electric strength
P
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
Output overload test, the most
unfavorable load test.
unfavorable load test.
(see appended table 5.3)
P
5.3.2
Motors
No motors.
N/A
5.3.3
Transformers
With the shorted o/p of the
transformer, no high
temperature of the transformer
was recorded.
transformer, no high
temperature of the transformer
was recorded.
Results of the short-circuit tests
see appended table 5.3 and
Annex C.
see appended table 5.3 and
Annex C.
P
5.3.4
Functional insulation .............................................: Method c). Test results see
appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component provided.
component provided.
N/A
5.3.6
Simulation of faults
Results see appended table.
P
5.3.7
Unattended equipment
None of the listed components
was provided.
was provided.
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire propagated beyond the
equipment. No molten metal
was emitted. Electric strength
test primary to SELV was
passed.
equipment. No molten metal
was emitted. Electric strength
test primary to SELV was
passed.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
No TNV.
N/A
Test voltage (V) ...................................................:
Current in the test circuit (mA) ............................:
6.1.2.2
Exclusions.............................................................:
N/A
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1
Separation requirements
No TNV.
N/A
<12014238 001 >
Page 23 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) .........................................: No TNV.
Current limiting method ........................................:
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service
persons, and users of other equipment
connected to the system, from hazardous
voltages in the equipment
persons, and users of other equipment
connected to the system, from hazardous
voltages in the equipment
Not connected to cable
distribution system
distribution system
N/A
7.2
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
7.3
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.3.1
General
N/A
7.3.2
Voltage surge test
N/A
7.3.3
Impulse test
N/A
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
P
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples................................................................:
Wall thickness (mm) .............................................:
A.1.2
Conditioning of samples; temperature (°C) ..........:
N/A
A.1.3
Mounting of samples ............................................:
N/A
A.1.4
Test flame (see IEC 60695-11-3)
N/A
Flame A, B, C or D ...............................................:
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) ....................................:
Sample 2 burning time (s) ....................................:
Sample 3 burning time (s) ....................................:
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
P