<12014238 001 > 
 
 
Page 20 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
Normal load condition per Annex L.......................:  See 1.6.2. 
4.5.2 
Resistance to abnormal heat 
See appended table 4.5.2. 
 
4.6 
Openings in enclosures 
4.6.1 
Top and side openings 
No openings 
 
Dimensions (mm)  ................................................:   
 
4.6.2 
Bottoms of fire enclosures 
No openings 
 
Construction of the bottom ...................................:   
 
4.6.3 
Doors or covers in fire enclosures 
No such things. 
N/A 
4.6.4 
Openings in transportable equipment 
No opening. 
N/A 
4.6.5 
Adhesives for constructional purposes 
No adhesive. 
N/A 
 
Conditioning temperature (°C)/time (weeks) ........:   
 
 
 
 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame 
Use of materials with the 
required flammability classes. 
 
Method 1, selection and application of 
components wiring and materials 
(see appended table 4.7) 
 
Method 2, application of all of simulated fault 
condition tests 
 
N/A 
4.7.2 
Conditions for a fire enclosure 
See below. 
4.7.2.1 
Parts requiring a fire enclosure 
With having the following parts: 
▪ Components in primary 
▪ Components in secondary 
▪ Components having 
unenclosed arcing parts at 
hazardous voltage or energy 
level 
▪ Insulated wiring  
The fire enclosure is required. 
4.7.2.2 
Parts not requiring a fire enclosure 
 
N/A 
4.7.3 
Materials 
4.7.3.1 
General 
Parts mounted on PCB of 
flammability class V-0 or better. 
4.7.3.2 
Materials for fire enclosures 
The fire enclosure is V-1 or 
better material. 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
No part outside fire enclosure. 
N/A 
 
 
<12014238 001 > 
 
 
Page 21 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
4.7.3.5 
Materials for air filter assemblies 
No air filters provided. 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No high voltage components 
provided. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
5.1.1 
General 
See sub-clauses 5.1.2 to 5.1.6. 
5.1.2 
Equipment under test (EUT) 
EUT has only one mains 
connection. 
5.1.3 
Test circuit 
Equipment of figure 5A used. 
5.1.4 
Application of measuring instrument 
Using measuring instrument in 
annex D. 
5.1.5 
Test procedure 
The touch current was 
measured from mains to DC 
output connector and to a 100 
mm × 200 mm metal foil 
wrapped on accessible non-
conductive parts (plastic 
enclosure). 
5.1.6 
Test measurements 
See below. 
 
Test voltage (V)  ...................................................:  See appended table 5.1.6. 
 
 
Measured touch current (mA) ..............................:  See appended table 5.1.6. 
 
 
Max. allowed touch current (mA)  .........................:  See appended table 5.1.6. 
 
 
Measured protective conductor current (mA)  ......:   
 
 
Max. allowed protective conductor current (mA)  .:   
 
5.1.7 
Equipment with touch current exceeding 3.5 mA  :  Neither stationary permanently 
connected equipment nor 
stationary pluggable equipment 
type B. 
N/A 
5.1.8 
Touch currents to and from telecommunication 
networks and cable distribution systems and from 
telecommunication networks 
No TNV. 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network and a cable 
distribution system 
 
N/A 
 
Test voltage (V)  ...................................................:   
 
 
Measured touch current (mA) ..............................:   
 
 
Max. allowed touch current (mA)  .........................:   
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks ................................: 
 
N/A 
 
 
<12014238 001 > 
 
 
Page 22 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
5.2 
Electric strength 
5.2.1 
General 
(see appended table 5.2)  
5.2.2 
Test procedure  
(see appended table 5.2)  
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
Output overload test, the most 
unfavorable load test. 
(see appended table 5.3) 
5.3.2 
Motors 
No motors. 
N/A 
5.3.3 
Transformers 
With the shorted o/p of the 
transformer, no high 
temperature of the transformer 
was recorded. 
Results of the short-circuit tests 
see appended table 5.3 and 
Annex C. 
5.3.4 
Functional insulation .............................................:  Method c). Test results see 
appended table 5.3. 
5.3.5 
Electromechanical components 
No electromechanical 
component provided. 
N/A 
5.3.6 
Simulation of faults 
Results see appended table. 
5.3.7 
Unattended equipment 
None of the listed components 
was provided. 
N/A 
5.3.8 
Compliance criteria for abnormal operating and 
fault conditions 
No fire propagated beyond the 
equipment. No molten metal 
was emitted. Electric strength 
test primary to SELV was 
passed. 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
No TNV.  
N/A 
 
Test voltage (V)  ...................................................:   
 
 
Current  in the test circuit (mA) ............................:   
 
6.1.2.2 
Exclusions.............................................................:   
N/A 
 
 
 
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
N/A 
6.2.1 
Separation requirements 
No TNV. 
N/A 
 
 
<12014238 001 > 
 
 
Page 23 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 
Impulse test 
 
N/A 
6.2.2.2 
Steady-state test 
 
N/A 
6.2.2.3 
Compliance criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
N/A 
 
Max. output current (A) .........................................:  No TNV. 
 
 
Current limiting method ........................................:   
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
N/A 
7.1 
Protection of cable distribution system service 
persons, and users of other equipment 
connected to the system, from hazardous 
voltages in the equipment 
Not connected to cable 
distribution system 
N/A 
7.2 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
N/A 
7.3 
Insulation between primary circuits and cable 
distribution systems 
 
N/A 
7.3.1 
General 
 
N/A 
7.3.2 
Voltage surge test 
 
N/A 
7.3.3 
Impulse test 
 
N/A 
 
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
A.1 
Flammability test for fire enclosures of movable equipment having a total mass 
exceeding 18 kg, and of stationary equipment (see 4.7.3.2) 
N/A 
A.1.1 
Samples................................................................:   
 
 
Wall thickness (mm) .............................................:   
 
A.1.2 
Conditioning of samples; temperature (°C) ..........:   
N/A 
A.1.3 
Mounting of samples ............................................:   
N/A 
A.1.4 
Test flame (see IEC 60695-11-3) 
 
N/A 
 
Flame A, B, C or D ...............................................:   
 
A.1.5 
Test procedure 
 
N/A 
A.1.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ....................................:   
 
 
Sample 2 burning time (s) ....................................:   
 
 
Sample 3 burning time (s) ....................................:   
 
A.2 
Flammability test for fire enclosures of movable equipment having a total mass not 
exceeding 18 kg, and for material and components located inside fire enclosures 
(see 4.7.3.2 and 4.7.3.4) 