Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
14.6.1 
Add the following paragraph after NOTE. 
The  following  manually  operated  mechanical 
switches  shall meet the  requirements  specified in 
item a) or b) below. 
-  the  controlling  current  exceeds  0.2  A  r.m.s  a.c. 
or d.c. 
-  the  voltage  across  the  open  switch  contacts 
exceeds 35 Vpeak ac or 24 Vdc.  
 
N/A 
14.6.1 
In  item  a),  replace IEC  61058-
1 by “IEC 61058-1 
or JIS C 4526-
1:1999”. 
 
N/A
 
14.6.2 
Replace  IEC  61058-
1  by  “IEC  61058-1  or  JIS  C 
4526-
1:1999”. 
 
N/A
 
14.6.3 
Replace  IEC  61058-
1 by “ IEC 61058-1 or JIS C 
4526-
1:1999”. 
 
N/A
 
14.6.5 
Replace  IEC  61058-
1 by “ IEC 61058-1 or JIS C 
4526-
1:1999”. 
 
N/A
 
14.7 
Replace IEC 60950 by JIS C 6950:2006. 
 
N/A 
 
 
 
 
Page 81 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
15.1.1 
Replace  the  first  and  second  paragraph  by  the 
following. 
Plugs  and  appliance  couplers  for  the  connection 
of the apparatus to the MAINS and socket-outlets 
and  interconnection  couplers  shall  comply  with 
the  relevant  JIS  standards.  If  there  is  no 
appropriate  JIS  standard,  they  shall  comply  with 
the relevant IEC standards. 
Appliance connectors, interconnection outlets and 
interconnection  plug-connectors  compiled  with 
Appendix  3  of  the  Ministerial  Ordinance  on 
stipulating 
technical 
requirements 
for 
the 
Electrical Appliance and Material are accepted. In 
that case, if due to the shape the contact parts are 
connectable to those specified in standard sheets 
of  IEC  60320-1,  they  shall  comply  with 
dimensions  and  ratings  specified  in  the  relevant 
standard sheets of IEC 60320-1. 
Examples 
of 
relevant 
specifications 
and 
standards: 
- Plugs / Socket-outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2  (corresponding  to  IEC  60884)  of  the 
Ordinance. 
-  Appliance  couplers:  Appendix  4  of  Article  1  of 
the  Ministerial  Ordinance  on  stipulating  technical 
requirements for the Electrical Appliance. Article 2 
(corresponding to IEC 60320-1) of the Ordinance. 
- Appliance inlets: IEC 60320-1 
-  Interconnection  outlets:  Appendix  4  of  Article  1 
of  the  Ministerial  Ordinance  on  stipulating 
technical 
requirements 
for 
the 
Electrical 
Appliance. IEC 60320-2-2.  
- Interconnection couplers: Appendix 4 of Article 1 
of  the  Ministerial  Ordinance  on  stipulating 
technical 
requirements 
for 
the 
Electrical 
Appliance.  
Delete NOTE 1 and NOTE 2. 
 
 
 
 
 
Approved AC inlet used. See 
table 14. 
 
 
 
 
 
 
 
 
 
 
 
15.1.1 
Replace  the  paragraph  after  NOTE  2  by  the 
following. 
MAINS 
socket-outlets 
and 
interconnection 
couplers  mounted  on  CLASS  0I  and  CLASS  II 
apparatus shall not permit connection of CLASS I 
apparatus. 
 
 
 
 
 
Page 82 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
15.1.1 
Replace  the  paragraph  before  NOTE  3  by  the 
following. 
MAINS 
socket-outlets 
and 
interconnection 
couplers mounted on CLASS I apparatus shall be 
provided  with  protective  earthing  contacts  which 
are  reliably  connected  to  the  PROTECTIVE 
EARTHING  TERMINAL  or  contact  of  the 
apparatus.  If  not, it  shall  not  permit  connection  of 
CLASS I apparatus. 
Not class I equipment. 
N/A 
15.1.1 
Replace NOTE 4 by the following. 
NOTE  4    Socket-outlets  not  allowing  the 
connection  of  CLASS  I  apparatus  can  be 
designed,  for  instance,  similar  to  IEC  60906-1, 
standard  sheets  3-1  or  3-2,  or  according  to  IEC 
60320-2-2, standard sheets D or H. 
 
N/A 
15.1.2 
Delete the following sentence in NOTE.  
An  example  of  a  connector  not  meeting  the 
requirements  of  this  sub  clause  is  the  so-called 
"banana" plug. 
 
 
 
 
 
15.1.3 
Replace  the  references,  “IEC  60083  [1],  IEC 
60320,  IEC  60884,  IEC  60906”  by  “JIS  C  8282 
(corresponding  to  IEC  60884),  JIS  C  8303,  IEC 
60320 and IEC 60906”. 
 
15.2 
Add  “and  CLASS  0I  EQUIPMENT”  after  the 
words, “CLASS I EQUIPMENT”  
No earthing. 
N/A 
15.2 
Add  the  following  paragraphs  after  the  first 
paragraph. 
The  external  earth  wire  of  plug  with  an  external 
earth wire shall not be earthed by a clip. 
Rated  voltage  of  plug  with  an  protective  external 
earth wire shall be less 150 Vac. 
 
N/A 
15.2 
Delete the following paragraph. 
In supply apparatus of Class I with non-hazardous 
live  output  voltage,  output  circuits  shall  not  be 
connected to the protective earthing conductor. 
 
N/A 
15.3.1 
In the first paragraph, replace IEC 60998-2-
2 by “ 
IEC 60998-2-2 or JIS C 2814-2-
2:2001”. 
AC inlet used. 
N/A 
15.3.1 
In  the  first  paragraph,  replace  IEC  60999  by  IEC 
60999-1. 
 
N/A 
15.3.1 
In  the  third  paragraph,  replace  IEC  60335-1  by 
JIS  C  9335-1:2003  (corresponding  to  IEC  60335-
1).  
 
N/A 
15.3.3 
Replace  “ISO  261  or  ISO  262”  by  “JIS  B  0205-
2:2001 or JIS B 0205-
3:2001”. 
 
N/A 
 
 
 
 
Page 83 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
15.3.5 
In  the  second  paragraph,  replace  IEC  60950  by 
JIS C 6950:2006. 
 
N/A 
15.3.5 
 Replace Table 15 by the following. 
 
N/A 
   
 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-sectional 
area 
mm
2
 
 
Up to and including 6 
         0.75 to 1 
 
 
Over 6 up to and including 10 
         1     to  1.5 
 
 
Over 10 up to and including 16 
         1.5  to  2.5 
 
 
  The  RATED  CURRENT  CONSUMPTION  includes 
currents  which  can  be  drawn  from  socket-outlets 
providing MAINS power for other apparatus. 
 
 
 
 
15.3.9 
Add the following to the last of the first paragraph. 
This  does  not  apply  to  CLASS  0I  EQUIPMENT 
with a protection earthing terminal separately. 
 
N/A 
15.4.1 
In  NOTE  1,  replace  IEC  60884-1  by  JIS  C  8282 
(corresponding to IEC 60884-1).  
Not such equipment. 
N/A 
15.4.1 
In NOTE 2, replace IEC 60083 [1] by JIS C 8303. 
 
N/A 
15.4.2 
In  NOTE,  replace  IEC  60083  [1]  by  JIS  C 
8303:1993 [1]. 
 
N/A 
15.4.3 
Add the following NOTE to Table 17. 
NOTE  If mains plug is parallel blade, a pull force 
as given in  “Over 10 A up to and including 16 A, 
130/250 V
” of Table 17 is applied. 
 
N/A 
16.1 
Add the following to the last of first paragraph. 
Or  mains  cords  shall  be  of  the  sheathed  type 
complying  with  Appendix  1  of  Article  1  of  the 
Ministerial  Ordinance  on  stipulating  technical 
requirements for the Electrical Appliance.  
Delete NOTE 1. 
Replace the second paragraph by the following. 
Compliance  is  checked  by  testing  MAINS  supply 
flexible  cords  in  accordance  with  JIS  C  3662 
(corresponding  to  IEC60227)  or  JIS  C  3663 
(corresponding  to  IEC  60245)  or  Appendix  1  of 
Article 1 of the Ministerial Ordinance on stipulating 
technical 
requirements 
for 
the 
Electrical 
Appliance.  
Shall be evaluated during 
national approval.  
N/A 
16.1 
In  this  sub-clause,  replace  IEC  60227  by  JIS  C 
3662 (corresponding to IEC 60227). 
In  this  sub-clause,  replace  IEC  60245  by  JIS  C 
3663 (corresponding to IEC 60245). 
 
N/A 