JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 80 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
14.6.1
Add the following paragraph after NOTE.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
or d.c.
- the voltage across the open switch contacts
exceeds 35 Vpeak ac or 24 Vdc.
N/A
14.6.1
In item a), replace IEC 61058-
1 by “IEC 61058-1
or JIS C 4526-
1:1999”.
N/A
14.6.2
Replace IEC 61058-
1 by “IEC 61058-1 or JIS C
4526-
1:1999”.
N/A
14.6.3
Replace IEC 61058-
1 by “ IEC 61058-1 or JIS C
4526-
1:1999”.
N/A
14.6.5
Replace IEC 61058-
1 by “ IEC 61058-1 or JIS C
4526-
1:1999”.
N/A
14.7
Replace IEC 60950 by JIS C 6950:2006.
N/A
Page 81 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
15.1.1
Replace the first and second paragraph by the
following.
following.
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers shall comply with
the relevant JIS standards. If there is no
appropriate JIS standard, they shall comply with
the relevant IEC standards.
of the apparatus to the MAINS and socket-outlets
and interconnection couplers shall comply with
the relevant JIS standards. If there is no
appropriate JIS standard, they shall comply with
the relevant IEC standards.
Appliance connectors, interconnection outlets and
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating
technical
requirements
for
the
Electrical Appliance and Material are accepted. In
that case, if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with
dimensions and ratings specified in the relevant
standard sheets of IEC 60320-1.
that case, if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with
dimensions and ratings specified in the relevant
standard sheets of IEC 60320-1.
Examples
of
relevant
specifications
and
standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60884) of the
Ordinance.
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60884) of the
Ordinance.
- Appliance couplers: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article 2
(corresponding to IEC 60320-1) of the Ordinance.
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article 2
(corresponding to IEC 60320-1) of the Ordinance.
- Appliance inlets: IEC 60320-1
- Interconnection outlets: Appendix 4 of Article 1
of the Ministerial Ordinance on stipulating
technical
technical
requirements
for
the
Electrical
Appliance. IEC 60320-2-2.
- Interconnection couplers: Appendix 4 of Article 1
of the Ministerial Ordinance on stipulating
technical
technical
requirements
for
the
Electrical
Appliance.
Delete NOTE 1 and NOTE 2.
Approved AC inlet used. See
table 14.
table 14.
P
15.1.1
Replace the paragraph after NOTE 2 by the
following.
following.
MAINS
socket-outlets
and
interconnection
couplers mounted on CLASS 0I and CLASS II
apparatus shall not permit connection of CLASS I
apparatus.
apparatus shall not permit connection of CLASS I
apparatus.
P
Page 82 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
15.1.1
Replace the paragraph before NOTE 3 by the
following.
following.
MAINS
socket-outlets
and
interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
Not class I equipment.
N/A
15.1.1
Replace NOTE 4 by the following.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
N/A
15.1.2
Delete the following sentence in NOTE.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
requirements of this sub clause is the so-called
"banana" plug.
P
15.1.3
Replace the references, “IEC 60083 [1], IEC
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
P
15.2
Add “and CLASS 0I EQUIPMENT” after the
words, “CLASS I EQUIPMENT”
words, “CLASS I EQUIPMENT”
No earthing.
N/A
15.2
Add the following paragraphs after the first
paragraph.
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
earth wire shall be less 150 Vac.
N/A
15.2
Delete the following paragraph.
In supply apparatus of Class I with non-hazardous
live output voltage, output circuits shall not be
connected to the protective earthing conductor.
live output voltage, output circuits shall not be
connected to the protective earthing conductor.
N/A
15.3.1
In the first paragraph, replace IEC 60998-2-
2 by “
IEC 60998-2-2 or JIS C 2814-2-
2:2001”.
AC inlet used.
N/A
15.3.1
In the first paragraph, replace IEC 60999 by IEC
60999-1.
60999-1.
N/A
15.3.1
In the third paragraph, replace IEC 60335-1 by
JIS C 9335-1:2003 (corresponding to IEC 60335-
1).
JIS C 9335-1:2003 (corresponding to IEC 60335-
1).
N/A
15.3.3
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-
2:2001 or JIS B 0205-
3:2001”.
N/A
Page 83 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
15.3.5
In the second paragraph, replace IEC 60950 by
JIS C 6950:2006.
JIS C 6950:2006.
N/A
15.3.5
Replace Table 15 by the following.
N/A
RATED CURRENT
CONSUMPTION of the
apparatus
a
A
Nominal cross-sectional
area
mm
2
Up to and including 6
0.75 to 1
Over 6 up to and including 10
1 to 1.5
Over 10 up to and including 16
1.5 to 2.5
a
The RATED CURRENT CONSUMPTION includes
currents which can be drawn from socket-outlets
providing MAINS power for other apparatus.
providing MAINS power for other apparatus.
15.3.9
Add the following to the last of the first paragraph.
This does not apply to CLASS 0I EQUIPMENT
with a protection earthing terminal separately.
with a protection earthing terminal separately.
N/A
15.4.1
In NOTE 1, replace IEC 60884-1 by JIS C 8282
(corresponding to IEC 60884-1).
(corresponding to IEC 60884-1).
Not such equipment.
N/A
15.4.1
In NOTE 2, replace IEC 60083 [1] by JIS C 8303.
N/A
15.4.2
In NOTE, replace IEC 60083 [1] by JIS C
8303:1993 [1].
8303:1993 [1].
N/A
15.4.3
Add the following NOTE to Table 17.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V
as given in “Over 10 A up to and including 16 A,
130/250 V
” of Table 17 is applied.
N/A
16.1
Add the following to the last of first paragraph.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance.
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance.
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical
requirements
for
the
Electrical
Appliance.
Shall be evaluated during
national approval.
national approval.
N/A
16.1
In this sub-clause, replace IEC 60227 by JIS C
3662 (corresponding to IEC 60227).
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
3663 (corresponding to IEC 60245).
N/A
Click on the first or last page to see other CINEMA 610 service manuals if exist.