JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 92 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
14.2
Component power supplies and their capacitors
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
N/A
14.2.1
As an alternative, a component such as a capacitor,
a combination capacitor and resistor, or a
suppressor may comply with UL 1414.
a combination capacitor and resistor, or a
suppressor may comply with UL 1414.
P
14.2.2
As an alternative, a capacitor, a combination
capacitor and resistor, or a varistor, or a suppressor
may comply with UL 1414.
capacitor and resistor, or a varistor, or a suppressor
may comply with UL 1414.
P
14.2.4
Components subjected to the requirements in 14.2.1
and 14.2.2 also comply with UL 1414 enclosure
requirements
and 14.2.2 also comply with UL 1414 enclosure
requirements
N/A
14.3
Component power supplies and their inductors and
windings complying with UL 1310, UL 1950 3
windings complying with UL 1310, UL 1950 3
rd
Ed.,
or UL 60950 are considered to fulfill the clause
N/A
14.4
High voltage materials are rated V-2 minimum
N/A
14.4.1
High voltage arcing test replaces the High voltage
transformers and multipliers test
transformers and multipliers test
N/A
14.4.2
Deleted
N/A
14.4.3
High voltage component part flame test
N/A
14.4.4
High voltage isolating component test
N/A
14.5.1.1
Thermal cut-outs comply with UL 873, UL 8730-2-9
or UL 60730-2-9
or UL 60730-2-9
N/A
14.5.1.2
Thermal links comply with UL 60691
N/A
14.5.1.3
Deleted
N/A
14.5.2.1
Fuse links comply with UL 248-14
P
14.5.2.2
Reference to IEC 60127 is deleted
P
Pre-arcing time/current characteristic and breaking
capacity marking requirements are deleted
capacity marking requirements are deleted
P
14.5.3
As an alternative, a PTC thermistor may comply with
requirements of UL 1434
requirements of UL 1434
N/A
14.5.4
Reference to fuse-links is deleted
N/A
Other protective devices directly connected to the
mains have adequate breaking capacity and comply
with UL 873, UL 1416, UL 1417 or UL 2111
mains have adequate breaking capacity and comply
with UL 873, UL 1416, UL 1417 or UL 2111
N/A
14.6.1
Switches and relays comply with UL 1054, UL
61058-1 or UL 508
61058-1 or UL 508
No such switch
N/A
Mains switch or relay are rated for the total rated
current consumption of the apparatus
current consumption of the apparatus
N/A
Page 93 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
Rating of a mains switch or relay in audio apparatus
intended for commercial use
intended for commercial use
N/A
14.6.2 - .4 Deleted
N/A
14.6.5
A switch or relay that controls a mains socket-outlet
have a rating equal to the rated current consumption
of the apparatus plus the current rating of the socket-
outlet
have a rating equal to the rated current consumption
of the apparatus plus the current rating of the socket-
outlet
N/A
14.6.6
Mains switches comply with (a), (b) or (c)
N/A
Mains relay contacts comply with (a), (b) or (d)
N/A
A switch that controls a mains receptacle complies
with (b) and a relay that controls a mains receptacle
complies with (b) or (d)
with (b) and a relay that controls a mains receptacle
complies with (b) or (d)
N/A
14.6.6a
Switch or relay contacts have current rating equal to
or greater than 1.414 times the inrush current of the
apparatus
or greater than 1.414 times the inrush current of the
apparatus
N/A
14.6.6b
Switch or relay is TV rated
N/A
14.6.6c
Switch is located on the back of apparatus and is not
operable from a remote control
operable from a remote control
N/A
14.6.6d
Relay subjected to the Relay Endurance Test
N/A
14.6.6.1
Peak inrush current test
N/A
14.6.6.2
Relay endurance test
N/A
14.6.7
Double pole switch controlling a.c. and d.c. circuits
N/A
14.7
The jointed test finger (Fig 14) is used to determine
accessibility and operation of the interlock
accessibility and operation of the interlock
N/A
14.10.1
– 14.10.5.
N/A
Test requirements from UL 2054 added for special
battery packs that are removable by the user from
the apparatus (Short circuit, Abnormal charging,
Forced-discharge, and 250-N steady force tests may
be carried separately from the apparatus)
battery packs that are removable by the user from
the apparatus (Short circuit, Abnormal charging,
Forced-discharge, and 250-N steady force tests may
be carried separately from the apparatus)
N/A
Note: Consumer grade, non-rechargeable carbon-
zinc or alkaline batteries are not subjected to the
tests specified in Clauses 14.10.2
zinc or alkaline batteries are not subjected to the
tests specified in Clauses 14.10.2
– 14.10.5.
N/A
14.10.5
Alternatively, one sample subjected to three drops
N/A
14.10.6
Location of overcurrent protective device ............. :
N/A
Alternatively, the overcurrent protective device in the
apparatus battery-supply circuit is not required if the
apparatus is to be connected to a vehicle power
outlet via UL 2089 vehicle battery adapter
apparatus battery-supply circuit is not required if the
apparatus is to be connected to a vehicle power
outlet via UL 2089 vehicle battery adapter
N/A
Page 94 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
14.11
Component power supplies and their optocouplers
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
N/A
Optocouplers comply with UL 1577
P
Optocouplers bridging reinforced insulation comply
with requirements for double protection as specified
in UL 1577
with requirements for double protection as specified
in UL 1577
P
External clearances and creepage distances of
optocouplers comply with 13.1
optocouplers comply with 13.1
P
14.12
Reference to IEC 61051-2 replaced by UL 1449
No varistor used.
N/A
Reference to IEC 60707 replaced by UL 94
P
All references to IEC 60151 are deleted
N/A
15.1.1
Attachment plug current rating (no less than 125% of
the current drawn under normal operating conditions)
and voltage rating ................................................ :
the current drawn under normal operating conditions)
and voltage rating ................................................ :
(see appended table 14)
P
Configuration and electrical rating of an attachment
plug for apparatus for use on more than one supply
voltage by means of a voltage selector ................ :
plug for apparatus for use on more than one supply
voltage by means of a voltage selector ................ :
N/A
Polarized attachment plug
N/A
Wire gauge of conductors and internal wiring
connecting mains socket-outlets
connecting mains socket-outlets
N/A
15.1.3.1
Means of output connections on an audio amplifier
having an open-circuit audio output voltage not
limited to 120 V that is permanently connected to the
mains
having an open-circuit audio output voltage not
limited to 120 V that is permanently connected to the
mains
Not more than 120V.
N/A
Quick Connect Terminals:
N/A
a) Male tabs firmly mounted in place;
N/A
b) Mating female connectors provided with the
apparatus;
apparatus;
N/A
c) Strain Relief Test of Clause 16.5;
N/A
d) Installation instructions provided for assembly of
terminal to a conductor and strain relief
terminal to a conductor and strain relief
N/A
e) Terminals are appropriate for use with the size
and type of wire specified
and type of wire specified
N/A
15.1.3.2
Audio amplifiers having an audio output not limited to
120 V that are connected to the mains by a flexible
cord
120 V that are connected to the mains by a flexible
cord
N/A
15.2
Cross-sectional area of the earthing conductor in a
supply cord or in an interconnecting cable
supply cord or in an interconnecting cable
N/A
Page 95 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
Earthing conductors may have green or green/yellow
insulation
insulation
N/A
15.3.5
Reference to IEC 60950 is replaced by Article 310 of
the National Electrical Code, ANSI/NFPA 70
the National Electrical Code, ANSI/NFPA 70
N/A
Table 15 - "AWG" replace mm2 values
N/A
15.4
Component power supply adaptors complying with
UL 1310, UL 1950 Third Edition, or UL 60950 fulfill
the clause
UL 1310, UL 1950 Third Edition, or UL 60950 fulfill
the clause
N/A
16.1
Reference in the first paragraph to “sheathed”
flexible cords is deleted
flexible cords is deleted
(see appended table 14)
P
References to IEC 60227 and IEC 60245 deleted
N/A
Ampacity and VW-1 marking of mains supply flexible
cords ................................................................... :
cords ................................................................... :
N/A
Table 17A - Cords for apparatus
N/A
16.2
Power supply cord earthing conductor size .......... :
N/A
Reference to IEC 60950, Table 3B is replaced by
Article 400 of the National Electrical Code
Article 400 of the National Electrical Code
N/A
Table 18 - Upper current limit in column 1 increased
from 16 to 30 A and "AWG" wire sizes
from 16 to 30 A and "AWG" wire sizes
N/A
16.3
c) Flexible cords not complying with 16.1, used as
connection between the apparatus and other
apparatus are marked VW-1
connection between the apparatus and other
apparatus are marked VW-1
N/A
16.5
When polymeric materials are involved, strain and
twist testing is to be conducted before and after the
sub-clause 12.1.5 stress relief test.
twist testing is to be conducted before and after the
sub-clause 12.1.5 stress relief test.
N/A
17.8
Expanded to include all cart/stand parts supplied by
the manufacturer, such as casters and brackets.
Suitable assembly instructions are required.
the manufacturer, such as casters and brackets.
Suitable assembly instructions are required.
N/A
Relevant fixing means are not required when
installation is to be done by a skilled person
installation is to be done by a skilled person
N/A
17.10
Termination of aluminum conductors used as internal
wiring
wiring
N/A
17.11
An accessory was investigated to determine that: a).
The accessory, and the combination of the
accessory and the apparatus presents no hazard in
the sense of this standard, and
b). The accessory is provided with installation
instructions.
The accessory, and the combination of the
accessory and the apparatus presents no hazard in
the sense of this standard, and
b). The accessory is provided with installation
instructions.
N/A
17.11.1
Installation of an accessory by a skilled person:
a) The mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided as part of the installation kit,
a) The mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided as part of the installation kit,
N/A
Click on the first or last page to see other CINEMA 610 service manuals if exist.