Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
b) The electrical connections are made by using
existing terminals and connections in the apparatus
or the building wiring
existing terminals and connections in the apparatus
or the building wiring
N/A
18
Non-intrinsically protected picture tubes comply with
18.1, 18.2.2 and 18.3. Intrinsically protected picture
tubes with a maximum face dimension exceeding 7.5
cm comply with UL 61965.
18.1, 18.2.2 and 18.3. Intrinsically protected picture
tubes with a maximum face dimension exceeding 7.5
cm comply with UL 61965.
N/A
A bulb of a picture tube having a face diameter of 7.5
cm or more are mounted in an enclosure
cm or more are mounted in an enclosure
N/A
Enclosure opening dimensions
N/A
18.1
All tubes are mounted such that the enclosure of the
apparatus protects the tube against the effects of
implosion.
apparatus protects the tube against the effects of
implosion.
N/A
18.2
Clauses 18.2, 18.2.1 and 18.2.3 are deleted
N/A
19
The tests in 19.1, 19.2 and 19.3 do not cause the
apparatus to overturn.
apparatus to overturn.
N/A
The test in 19.2.1 does not cause the apparatus to
slide
slide
N/A
When polymeric materials are involved, testing is to
be conducted before and after the sub-clause 12.1.5
stress relief test.
be conducted before and after the sub-clause 12.1.5
stress relief test.
N/A
19.1
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2.1
Slide test
N/A
19.3
Horizontal force stability test using Table 20A values
from UL 60065
from UL 60065
N/A
19.5
Reference to the impact hammer in the first
compliance paragraph is deleted
compliance paragraph is deleted
N/A
19.6
Equipment rack mounting test
N/A
20.1a
Deleted
N/A
20.1b
Exception for parts such as protection TV lenses,
loudspeaker parts, external accessories, and fibrous
materials
loudspeaker parts, external accessories, and fibrous
materials
P
Reference to IEC 60707 replaced by UL 94
P
20.1.2
Sleeving, extruded tubing and insulation on wiring
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
P
Page 97 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
b) wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located in
a circuit that is a potential ignition source
ignition source but is in contact with wiring located in
a circuit that is a potential ignition source
N/A
20.1.2
Tape in contact with parts of circuits that are
potential ignition sources is flame retardant
potential ignition sources is flame retardant
P
20.1.3
Printed wiring boards, on which the available power
as the connection exceeds 15 W or the operating
voltage exceeds 50 V a.c. or d.c under normal
operating conditions, are of flammability category V-
1 or better
as the connection exceeds 15 W or the operating
voltage exceeds 50 V a.c. or d.c under normal
operating conditions, are of flammability category V-
1 or better
P
Reference to IEC 60707 replaced by UL 94
P
Exception for printed boards housed in metal
enclosures is deleted
enclosures is deleted
N/A
Option to use Clause G.1 of Annex G is deleted
N/A
20.1.4
Components and parts comply with the relevant
flammability category according to UL 94 as
specified in table 21
flammability category according to UL 94 as
specified in table 21
P
Component power supplies complying with UL1310,
UL1950 3rd Ed., or UL60950 fulfill the clause
UL1950 3rd Ed., or UL60950 fulfill the clause
N/A
Table 21 - Flammability categories for components
and parts
and parts
P
20.2.1
Fire enclosure required:
1) circuits and components where the available
power exceeds 15 W,
2) inductors and windings conductively connected to
the mains, and
3) high-voltage products.
1) circuits and components where the available
power exceeds 15 W,
2) inductors and windings conductively connected to
the mains, and
3) high-voltage products.
P
The fire enclosure complies with the flammability
requirements of Table 22 per UL 94 and 746C
requirements of Table 22 per UL 94 and 746C
The enclosure is made of
wood with min. 7mm thickness
and metal.
wood with min. 7mm thickness
and metal.
P
Reference to IEC 60707 or clause G.1 of annex G
replaced by UL 94 or UL 746C
replaced by UL 94 or UL 746C
P
Table 22 - Flammability categories for fire enclosures
P
20.2.2
N/A
Compliance is checked by inspection and
measurement and using the articulated finger probe,
figure 18.
measurement and using the articulated finger probe,
figure 18.
N/A
20.2.3
Outer enclosures have a minimum flammability
rating of HB when an internal fire enclosure is
provided
rating of HB when an internal fire enclosure is
provided
N/A
A
Apparatus intended for outdoor use or for wet locations
N/A
Page 98 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
a) provided with a means to be transportable
N/A
b) has a mass less than 35 kg
N/A
c) can be battery operated, or
N/A
d) associated literature states or implies such use
N/A
An apparatus as described in a), b), or c) above that
is marked as specified in 5.4.1 a) is not intended for
outdoor use or wet location use
is marked as specified in 5.4.1 a) is not intended for
outdoor use or wet location use
N/A
Apparatus permanently installed outdoors is
considered to be for permanent outdoor use
considered to be for permanent outdoor use
N/A
A.5
Clauses A.5, A.5.1 and A.5.4.1 are deleted
N/A
A.9.1.1
Touch current test after the water spray test
described in A.11.1.1
described in A.11.1.1
N/A
A.10
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted
N/A
A.11.1.1
Apparatus subjected to the water spray test specified
in UL 1598
in UL 1598
N/A
A.16.1
Flexible cords are suitable for outdoor use
N/A
A.20.2.1
Enclosures for an apparatus intended for permanent
outdoor location comply with requirements for Type 3
enclosures in UL 50
outdoor location comply with requirements for Type 3
enclosures in UL 50
N/A
B
IEC 62151 Clause 4 applies except for 4.1.2, 4.1.3,
4.2.1.1 and 4.2.1.2
4.2.1.1 and 4.2.1.2
N/A
The requirements of 4.2.1.1 are replaced by the
requirements or 2.3.1 of UL 60950, Third Edition
requirements or 2.3.1 of UL 60950, Third Edition
N/A
Voltages on the TNV-0 circuits, TNV-1 circuits and
accessible conductive parts in the event of a single
insulation fault
accessible conductive parts in the event of a single
insulation fault
N/A
Apparatus intended to be connected to
telecommunication networks and having ringing
voltages applied to the apparatus is subjected to
touch current limits in accordance with clause
5.1.8.1.1 of UL 60950
telecommunication networks and having ringing
voltages applied to the apparatus is subjected to
touch current limits in accordance with clause
5.1.8.1.1 of UL 60950
N/A
Telecommunication network that uses outside cable
complies with the requirements for protection against
overvoltage from power line crosses per 6.4 of UL
60950
complies with the requirements for protection against
overvoltage from power line crosses per 6.4 of UL
60950
N/A
UL 60950 Acoustic tests for apparatus containing an
earphone held against the ear
earphone held against the ear
N/A
Apparatus provided with appropriate markings and
instructions as described in Annex NAA of UL 60950
instructions as described in Annex NAA of UL 60950
N/A
D
Reference to IEC 60990 replaced by UL 101
P
Page 99 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
Add touch current value in MIU where
MIU = U2 x 2 (r.m.s. value)
MIU = U2 x 2 (r.m.s. value)
(U2peak x √2=MIU)
P
G
Annex G deleted
N/A
L
Annex L deleted
N/A
Q
Safety requirements for video apparatus for use in
health care facilities
health care facilities
N/A
R
Safety requirements for undercabinet apparatus
N/A
S
Safety requirements for in-wall mounted apparatus
N/A
T
Safety requirements for apparatus with projection
lamps
lamps
N/A
U
Safety requirements for permanently connected
apparatus
apparatus
N/A
V
Safety requirements for carts, stands, and similar
apparatus for use with specific apparatus covered by
this standard
apparatus for use with specific apparatus covered by
this standard
N/A
W
Construction details for a 0.02-ohm shunt for use in
the peak inrush-current measurement
the peak inrush-current measurement
N/A
X
Manufacturing and production-line tests and
verification
verification