DOWNLOAD JBL CINEMA 610 Service Manual ↓ Size: 1.79 MB | Pages: 108 in PDF or view online for FREE

Model
CINEMA 610
Pages
108
Size
1.79 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cinema-610.pdf
Date

JBL CINEMA 610 EMC - CB Certificate ▷ View online

 
 
 
 
Page 96 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
US National Differences acc. to IEC 60065:2001 + Amd 1:2005 
 
b) The electrical connections are made by using 
existing terminals and connections in the apparatus 
or the building wiring 
 
N/A 
18 
Non-intrinsically protected picture tubes comply with 
18.1, 18.2.2 and 18.3.  Intrinsically protected picture 
tubes with a maximum face dimension exceeding 7.5 
cm comply with UL 61965. 
 
N/A 
 
A bulb of a picture tube having a face diameter of 7.5 
cm or more are mounted in an enclosure 
 
N/A 
 
Enclosure opening dimensions 
 
N/A 
18.1 
All tubes are mounted such that the enclosure of the 
apparatus protects the tube against the effects of 
implosion. 
 
N/A 
18.2 
Clauses 18.2, 18.2.1 and 18.2.3 are deleted 
 
N/A 
19 
The tests in 19.1, 19.2 and 19.3 do not cause the 
apparatus to overturn. 
 
N/A 
 
The test in 19.2.1 does not cause the apparatus to 
slide 
 
N/A 
 
When polymeric materials are involved, testing is to 
be conducted before and after the sub-clause 12.1.5 
stress relief test. 
 
N/A 
19.1 
References to an apparatus in combination with a 
supplied cart or recommended stand are deleted 
 
N/A 
19.2 
References to an apparatus in combination with a 
supplied cart or recommended stand are deleted 
 
N/A 
19.2.1 
Slide test 
 
N/A 
19.3 
Horizontal force stability test using Table 20A values 
from UL 60065 
 
N/A 
19.5 
Reference to the impact hammer in the first 
compliance paragraph is deleted 
 
N/A 
19.6 
Equipment rack mounting test 
 
N/A 
20.1a 
Deleted 
 
N/A 
20.1b 
Exception for parts such as protection TV lenses, 
loudspeaker parts, external accessories, and fibrous 
materials 
 
 
Reference to IEC 60707 replaced by UL 94 
 
20.1.2 
Sleeving, extruded tubing and insulation on wiring 
are rated VW-1: 
 a) wiring located in a circuit that is considered a 
potential ignition source, or 
 
 
 
 
 
Page 97 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
US National Differences acc. to IEC 60065:2001 + Amd 1:2005 
 
b) wiring not located in a circuit that is a potential 
ignition source but is in contact with wiring located in 
a circuit that is a potential ignition source 
 
N/A 
20.1.2 
Tape in contact with parts of circuits that are 
potential ignition sources is flame retardant 
 
20.1.3 
Printed wiring boards, on which the available power 
as the connection exceeds 15 W or the operating 
voltage exceeds 50 V a.c. or d.c under normal 
operating conditions, are of flammability category V-
1 or better 
 
 
Reference to IEC 60707 replaced by UL 94 
 
 
Exception for printed boards housed in metal 
enclosures is deleted 
 
N/A 
 
Option to use Clause G.1 of Annex G is deleted 
 
N/A 
20.1.4 
Components and parts comply with the relevant 
flammability category according to UL 94 as 
specified in table 21 
 
 
Component power supplies complying with UL1310, 
UL1950 3rd Ed., or UL60950 fulfill the clause 
 
N/A 
 
Table 21 - Flammability categories for components 
and parts 
 
20.2.1 
Fire enclosure required: 
1) circuits and components where the available 
power exceeds 15 W,  
2) inductors and windings conductively connected to 
the mains, and  
3) high-voltage products. 
 
 
The fire enclosure complies with the flammability 
requirements of Table 22 per UL 94 and 746C 
The enclosure is made of 
wood with min. 7mm thickness 
and metal. 
 
Reference to IEC 60707 or clause G.1 of annex G 
replaced by UL 94 or UL 746C 
 
 
Table 22 - Flammability categories for fire enclosures   
20.2.2 
 
N/A 
 
Compliance is checked by inspection and 
measurement and using the articulated finger probe, 
figure 18. 
 
N/A 
20.2.3 
Outer enclosures have a minimum flammability 
rating of HB when an internal fire enclosure is 
provided 
 
N/A 
Apparatus intended for outdoor use or for wet locations  
N/A 
 
 
 
 
Page 98 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
US National Differences acc. to IEC 60065:2001 + Amd 1:2005 
 
a) provided with a means to be transportable 
 
N/A 
 
b) has a mass less than 35 kg 
 
N/A 
 
c) can be battery operated, or 
 
N/A 
 
d) associated literature states or implies such use 
 
N/A 
 
An apparatus as described in a), b), or c) above that 
is marked as specified in 5.4.1 a) is not intended for 
outdoor use or wet location use 
 
N/A 
 
Apparatus permanently installed outdoors is 
considered to be for permanent outdoor use 
 
N/A 
A.5 
Clauses A.5, A.5.1 and A.5.4.1 are deleted 
 
N/A 
A.9.1.1 
Touch current test after the water spray test 
described in A.11.1.1 
 
N/A 
A.10 
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted 
 
N/A 
A.11.1.1 
Apparatus subjected to the water spray test specified 
in UL 1598 
 
N/A 
A.16.1 
Flexible cords are suitable for outdoor use 
 
N/A 
A.20.2.1 
Enclosures for an apparatus intended for permanent 
outdoor location comply with requirements for Type 3 
enclosures in UL 50 
 
N/A 
IEC 62151 Clause 4 applies except for 4.1.2, 4.1.3, 
4.2.1.1 and 4.2.1.2 
 
N/A 
 
The requirements of 4.2.1.1 are replaced by the 
requirements or 2.3.1 of UL 60950, Third Edition 
 
N/A 
 
Voltages on the TNV-0 circuits, TNV-1 circuits and 
accessible conductive parts in the event of a single 
insulation fault 
 
N/A 
 
Apparatus intended to be connected to 
telecommunication networks and having ringing 
voltages applied to the apparatus is subjected to 
touch current limits in accordance with clause 
5.1.8.1.1 of UL 60950 
 
N/A 
 
Telecommunication network that uses outside cable 
complies with the requirements for protection against 
overvoltage from power line crosses per 6.4 of UL 
60950 
 
N/A 
 
UL 60950 Acoustic tests for apparatus containing an 
earphone held against the ear 
 
N/A 
 
Apparatus provided with appropriate markings and 
instructions as described in Annex NAA of UL 60950 
 
N/A 
Reference to IEC 60990 replaced by UL 101 
 
 
 
 
 
Page 99 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
US National Differences acc. to IEC 60065:2001 + Amd 1:2005 
 
Add touch current value in MIU where  
MIU = U2 x 2 (r.m.s. value) 
(U2peak x √2=MIU) 
Annex G deleted 
 
N/A 
Annex L deleted 
 
N/A 
Safety requirements for video apparatus for use in 
health care facilities 
 
N/A 
Safety requirements for undercabinet apparatus 
 
N/A 
Safety requirements for in-wall mounted apparatus 
 
N/A 
Safety requirements for apparatus with projection 
lamps 
 
N/A 
Safety requirements for permanently connected 
apparatus 
 
N/A 
Safety requirements for carts, stands, and similar 
apparatus for use with specific apparatus covered by 
this standard 
 
N/A 
Construction details for a 0.02-ohm shunt for use in 
the peak inrush-current measurement 
 
N/A 
Manufacturing and production-line tests and 
verification 
 
N/A 
Standards for components 
 
 
 
 
 
 
 
 
Page of 108