JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 88 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
APPENDIX US National Differences acc. to IEC 60065:2001 + Amd 1:2005
P
1.1.1
Delete reference to Annex L: Electronic flash
apparatus for photographic purposes and replace
with reference to UL 122.
apparatus for photographic purposes and replace
with reference to UL 122.
P
Mains connected apparatus intended for field
installation complies with the National Electrical
Code, ANSI, NFPA 70.
installation complies with the National Electrical
Code, ANSI, NFPA 70.
N/A
1.1.3
Requirements of apparatus intended for outdoor use
comply with applicable clause of Annex A
comply with applicable clause of Annex A
Indoor use only.
N/A
1.1.5
Some equipment covered by these requirements
may also be required to comply with applicable
requirements in other appropriate standards ........ :
may also be required to comply with applicable
requirements in other appropriate standards ........ :
P
4.2.1
The rated supply voltage for single phase apparatus
is assumed to be 120V or 120/240V
is assumed to be 120V or 120/240V
P
4.2.4
a) Minimum audio output is not less than 0.5 W per
channel unless the maximum audio output is less
than 0.5 W per channel
channel unless the maximum audio output is less
than 0.5 W per channel
N/A
4.2.4.1
An apparatus with multiple modes of operation,
multiple signal input sources, or both, is operated
according to the manufacturer's instructions to
produce the maximum power input
multiple signal input sources, or both, is operated
according to the manufacturer's instructions to
produce the maximum power input
N/A
4.2.11
Table 2 - External supply sources are assumed to be
capable of delivering 30 A, unless otherwise
specified (UL 60065 no-load voltage and internal
resistance values)
capable of delivering 30 A, unless otherwise
specified (UL 60065 no-load voltage and internal
resistance values)
P
4.3.4
As an alternative, PTC thermistors may also comply
with UL 1434.
with UL 1434.
N/A
5
As an alternative, a reagent grade hexane with a
minimum 85% as n-hexane may be used.
minimum 85% as n-hexane may be used.
N/A
Test for conductive labels secured in place by
adhesive
adhesive
N/A
5.1
Component power supplies and adapters complying
with UL 1310, UL 1950, or UL 60950 are considered
to fulfill items "a" through "i" of this clause.
with UL 1310, UL 1950, or UL 60950 are considered
to fulfill items "a" through "i" of this clause.
N/A
5.1f
Rated mains frequency marking on apparatus
P
5.1g
Rated current or power marking on apparatus
supplied by supply apparatus for general use
supplied by supply apparatus for general use
N/A
5.1j
Date of Manufacture marking
P
5.1k
Factory origin identification marking
P
5.1l
Combination of two graphical symbols and
supplementary marking and/or single graphical
symbol marking
supplementary marking and/or single graphical
symbol marking
P
Page 89 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
5.1m
Equipment rack marking for audio/video systems
N/A
5.1n
Class I apparatus having touch current levels greater
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high touch current marking.
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high touch current marking.
Class II equipment.
N/A
5.1o
Marking on apparatus having grille/ventilation areas
of the top surface that are permitted to have higher
temperature rises according to Note b of Table 3
of the top surface that are permitted to have higher
temperature rises according to Note b of Table 3
N/A
5.2c
Output terminals are marked with voltage, frequency
and current or power; output terminals installed or
interconnected in the field must be marked with the
class of wiring
and current or power; output terminals installed or
interconnected in the field must be marked with the
class of wiring
N/A
5.2d
Speaker terminals are marked "Class 1 Wiring",
"Class 2 Wiring" or "Class 3 Wiring".
"Class 2 Wiring" or "Class 3 Wiring".
Speakers and associated
wirings are provided.
wirings are provided.
N/A
5.2d
Operation manual explains risks and proper
connecting and insulating techniques when
connecting a speaker
connecting and insulating techniques when
connecting a speaker
N/A
5.3
An explanation and illustration of safety related
graphical symbols used on the apparatus are
included in the user instructions preceding any
operating instructions
graphical symbols used on the apparatus are
included in the user instructions preceding any
operating instructions
P
5.4
Important safety instructions are packed with each
apparatus
apparatus
P
5.4.1
Outdoor use marking for apparatus having no
protection against exposure to water
protection against exposure to water
N/A
5.4.1e
Deleted
N/A
5.4.1h
Reference to IEC 61695 is replaced by UL 61965
N/A
5.4.3
When user operation and installation instructions
contains instructions for use by skilled persons, the
instructions are separate in format and preceded by
a precautionary warning statement
contains instructions for use by skilled persons, the
instructions are separate in format and preceded by
a precautionary warning statement
N/A
6.1
Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by measuring
the radiation produced by the apparatus employing a
production chassis
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by measuring
the radiation produced by the apparatus employing a
production chassis
N/A
6.2
References to IEC 60825-1 are deleted
N/A
Apparatus is classified and labeled according to the
Code of Federal Regulations, Title 21, Chapter 1,
Subchapter J, Sections 1010.2, 1010.3, 1040.10 and
1040.11.
Code of Federal Regulations, Title 21, Chapter 1,
Subchapter J, Sections 1010.2, 1010.3, 1040.10 and
1040.11.
N/A
6.2.2
Deleted
N/A
Page 90 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
7
Table 3: Delete reference to conditions h and i under
Table item e for lithium batteries
Table item e for lithium batteries
N/A
Table 3: Temperature limits for various classes of
insulation systems according to UL 60065
insulation systems according to UL 60065
P
Table 3, Note a: Materials rated in accordance with
UL 746B may be used within their rated temperature
UL 746B may be used within their rated temperature
P
Table 3, Note b: For grille/ventilation areas in the top
surface directly above internal heatsinks, a
temperature rise up to 65 K is allowed
surface directly above internal heatsinks, a
temperature rise up to 65 K is allowed
N/A
7.2
Applies to thermoplastic materials only. A material
temperature rating can be accepted in lieu of the
softening temperature.
temperature rating can be accepted in lieu of the
softening temperature.
P
The softening test need not be performed on
materials used in UL Listed or Recognized
components
materials used in UL Listed or Recognized
components
N/A
8.1
Metal parts are corrosion resistant
N/A
8.9.1
Sleeving, tape, tubing, and wire insulation comply
with UL 224, UL 510, or UL 1441
with UL 224, UL 510, or UL 1441
P
8.10
Component power supplies and their internal
insulation complying with UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
clause
insulation complying with UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
clause
N/A
8.17
As an option, winding wire insulation complies with
the requirements in UL Subject 2353
the requirements in UL Subject 2353
N/A
8.19.1
An all-pole switch or circuit breaker is not required to
have contact separation of 3 mm
have contact separation of 3 mm
N/A
8.23
Printed wiring boards involved with the risk of electric
shock comply with the requirements in UL 796.
shock comply with the requirements in UL 796.
N/A
9.1.1.1
For Class I constructions the r.m.s. touch current to
earth is not more than 3.5 MIU
earth is not more than 3.5 MIU
N/A
9.1.1.1a
For audio signals of professional and commercial
apparatus, 120 V r.m.s.
apparatus, 120 V r.m.s.
N/A
For audio signals other than professional and
commercial apparatus, 71 V r.m.s.
commercial apparatus, 71 V r.m.s.
P
9.1.1.1b
Touch current carried out in accordance with UL 101
with the measuring instrument described in Annex D
does not exceed 0.5 MIU. Delete Note 2.
with the measuring instrument described in Annex D
does not exceed 0.5 MIU. Delete Note 2.
See table 9.1.1
P
9.1.1.2
UL articulated finger (figure 14) used instead of the
test probe B (IEC 61032)
test probe B (IEC 61032)
P
Reference to test probes 18 and 19 of IEC 61032 are
deleted
deleted
N/A
Page 91 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
10
Table 5, Note 1: With respect to mains voltages in
the range of 105-130 V (r.m.s.), the test voltages are
considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation
the range of 105-130 V (r.m.s.), the test voltages are
considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation
P
11
Component power supplies and their power
transformers complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are considered to fulfill the clause
transformers complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are considered to fulfill the clause
N/A
11.1
The permissible touch current for terminal contacts
increased to twice the value given in 9.1.1.1.
increased to twice the value given in 9.1.1.1.
See table 11.1
P
11.2.1
Additional fuse testing is not required if the
temperature is limited by fuses
temperature is limited by fuses
P
12
Component power supply adaptors and their
enclosures complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are deemed to fulfill the clause
enclosures complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are deemed to fulfill the clause
N/A
12.1.3
Impact test uses the 50 mm steel sphere only
P
Table 6 - Impact test criteria detailing impact
location, impact energy and additional pass/fail
results applied according to UL 60065
location, impact energy and additional pass/fail
results applied according to UL 60065
P
12.1.4
As an alternative, any number from one to three
samples are permitted to be used in any combination
that results in a total of three drops
samples are permitted to be used in any combination
that results in a total of three drops
N/A
12.1.6
Handle strength test. When polymeric materials are
involved, testing is to be condustresscted before and
after the sub-clause 12.1.5 stress relief test.
involved, testing is to be condustresscted before and
after the sub-clause 12.1.5 stress relief test.
N/A
12.8
Test for enclosures, barriers, components and leads
that rely on adhesive
that rely on adhesive
N/A
13
Component power supplies and their power
transformers complying with UL 1310, UL 1950 3
transformers complying with UL 1310, UL 1950 3
rd
Ed., or UL 60950 are deemed to fulfill the clause
N/A
13.4
The material group is verified according to UL 746A
P
Reference to the IEC 60112 PTI test is deleted
N/A
13.5.1
Reference to IEC 60249-2 is replaced by UL 796
P
13.5.2
Coated printed wiring boards comply with UL 746C
N/A
14
Annex Y and additional component requirements
applied according to UL 60065
applied according to UL 60065
P
14.1
Component power supplies and their resistors
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause
N/A
Click on the first or last page to see other CINEMA 610 service manuals if exist.