Page 76 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
ATTACHMENT TO TEST REPORT IEC 60065 
JAPAN NATIONAL DIFFERENCES 
Audio, video and similar electronic apparatus - Safety requirements
 
Differences according to ...............: 
IEC 60065:2001+amd.1:2005 
Attachment Form No. ....................: 
JP_ND_IEC60065J 
Attachment Originator ...................: 
UL Japan, Inc. 
Master Attachment ........................: 
2012-08 
 
National Differences - Japan 
1.1.3 
Add the following as a NOTE after the first sentence. 
NOTE  1    In  Japan,  the  requirements  for  regions 
with moderate apply. 
 
2.4.9 
In  NOTE  1,  replace  “see  4.2.2  of  IEC  62151”  by 
“see 4.2.2 of IEC 62151 [27]”. 
No TNV circuit 
N/A 
2.6.2A 
Add this sub clause. 
CLASS  0I  EQUIPMENT:  Equipment  which  has, 
as for protection against electric shock, 
-  at least using BASIC INSULATION, and 
-  providing  a  means  of  connecting  to  the 
protective  earthing  conductor  in  the  building 
wiring  those  conductive  parts  that  are 
otherwise  capable  of  assuming  HAZARDOUS 
VOLTAGES  if  the  BASIC  INSULATION  fails, 
and  
-  using a supply cord without earthing conductor 
and  a  plug  without  earthing  wire  although  the 
equipment  has  externally  an  earth  terminal  or 
a lead wire for earthing. 
Equipment provided with a cord set having a two-
pin  type  plug  with  a  lead  wire  for  earthing  or 
having three pin - tow pin adaptor is also regarded 
as Class 0I. 
NOTE    Class  0I  equipment  may  have  a  part 
constructed  with  Double  Insulation  or  Reinforced 
Insulation. 
Class II equipment 
N/A 
3.2 
Add the “Class 0I equipment” in the first sentence 
of this sub-clause. 
Added  
3.2 
Add  the  following  after  the  first  sentence  of  this 
sub-clause. 
NOTE    Equipment  often  transported  and  used 
should  not  be  Class  I  equipment  nor  Class  0I 
equipment. 
Added  
4.2.8 
Delete this clause. 
 
N/A 
4.3.4, b) 
Replace  IEC  60730-1  by  JIS  C  9730-1 
(corresponding to IEC 60730-1). 
 
4.3.12 
Delete this clause. 
 
N/A 
 
 
 
 
Page 77 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
4.3.13 
Replace  “250  V  a.c.”  by  “the  maximum  of  the 
variable range”. 
 
5.4.2A 
Add this sub-clause: 
For  CLASS  0I  EQUIPMENT,  the  following 
instruction shall be indicated where readily visible 
on the mains plug or the product: 
“WARNING:  Provide an earthing connection”  
Example in Japanese: 
 
Moreover,  for  CLASS  0I  EQUIPMENT,  the 
following  instruction  shall  be  indicated  where 
readily  visible  on  the  product  or  written  in  the 
operating instructions: 
“WARNING:    Provide  an  earthing  connection 
before the mains  plug is  connected  to  the mains. 
And, when disconnecting the earthing connection, 
be  sure  to  disconnect  after  pulling  out  the  mains 
plug from the mains.” 
Example in Japanese: 
 
Class II equipment. 
N/A 
6.2 
In  NOTE  1,  replace  IEC  61040  [10]  by  JIS  C 
6181:1995 [10]. 
No laser. 
N/A 
7.1.5 
Add  the  words,  “without  dimensions  restrictions” 
after  the  figure,  “65  K”  in  the  first  sentence  of 
Condition “b” in Table 3 as follows. 
For parts not likely to be touched during intended 
use,  temperature  rises  up  to  65  K  without 
dimensions  restrictions  are  allowed  under  normal 
operating conditions. 
 
 
 
 
 
Page 78 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
7.1.5 
Add  the  following  paragraph  as  2
nd
  paragraph  of 
Condition “d “in Table 3. 
For  materials  which  are  not  listed  in  Table  3, 
temperature  rises  in  the  normal  operating 
conditions  are  considered  satisfactory  if  these 
materials  comply  with  item  3  of  detailed 
regulations,  1.(1),b,  Appendix  4  in  the  Ministerial 
Ordinance  on  stipulating  technical  requirements 
for  the  Electrical  Appliance  and  Material. 
Permissible temperature rise of “Supply cords and 
wiring  insulation”  is  applicable  only  to  the 
materials  used  in  supply  cords  complying  with 
JIS C 3662 (corresponding to IEC 60227) or JIS C 
3663  (corresponding  to  IEC  60245).  Materials 
used  in  other  wiring  shall  comply  with  item  3  of 
detailed  regulations,  1.(1).b,  Appendix  4  in  the 
Ministerial  Ordinance  on  stipulating  technical 
requirements  for  the  Electrical  Appliance  and 
Material. 
 
7.1.5 
I
n  the  first  paragraph  of  Condition  “f”  of  Table  3, 
add  ”JIS  K  7206:1999  or”  before  the  reference, 
ISO 306. 
 
7.1.5 
In  Condition  “f,”  1)  of  Table  3,    add  ”JIS  K 
7206:1999 or” before the reference, ISO 306. 
 
7.2 
In NOTE 2, add ”or JIS standard” after the word, 
IEC standard. 
 
8.5 
In  the  first  paragraph,  add  “and  Class  0I 
Equipment” after the words, Class I Equipment. 
Not class I equipment. 
N/A 
8.5 
In  the  six  paragraph  (before  NOTE  3),  add  the 
following to the end of the first sentence. 
CLASS  0I  EQUIPMENT  shall  be  provided  with  a 
protective  earthing  terminal  in the  external  where 
easily  visible  or  a  protective  external  earth  wire 
from mains plug. 
 
N/A 
8.11 
In  NOTE  2,  c),  add  “or  JIS  C  2107,  JIS  C  2336, 
JIS C 2338” after the reference, IEC 60454.  
 
9.1.1.1 
In  the last  paragraph,  add  the following  sentence 
after the first sentence. 
For  CLASS  0I  EQUIPMENT,  the  r.m.s.  TOUCH-
CURRENT  to  earth  shall  not  be  more  than  1.0 
mA. 
 
N/A 
10 
In NOTE, replace “IEC 60664-1 and IEC 60664-4 
[9]”  by  “JIS  C  0664:2003  and  IEC/TR3  60664-4 
[8]” 
 
10.1 
Add “CLASS 0I EQUIPMENT and” to the head of 
the first paragraph. 
 
N/A 
10.3.2 
In  Table  5,  add  the  following  values  to  the  sub-
table of NOTE. 
 
 
 
 
 
Page 79 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Japan National Differences acc. to IEC 60065:2001 + A1 
 
Operating 
Voltage (peak) 
Test voltage (peak) 
 
 
Curve A 
Curve B 
 
 
142 V 
1 414 V 
2 828 V 
 
 
11.2.1 
Add the following after the original NOTE. 
NOTE 
 
The 
fuse 
except 
operating 
characteristics  specified  in  IEC  60127  shall  be 
tested in consideration of the characteristic. 
 
11.2.3 
Add “and CLASS 0I” after the words, CLASS I.  
 
13.4 
In  NOTE  2  of  Table  11,  replace  IEC  60664-1  by 
JIS C 0664:2003 (corresponding to IEC 60664-1). 
 
14.3.3.2 
In the second sentence of the first paragraph, add 
“or JIS C 2107, JIS C 2336 and JIS C 2338” after 
the reference, IEC 60454.  
 
14.5.1.1 
In item  a),  add  “JIS  C  9730  series  or”  before  the 
reference, IEC 60730 series. 
No such component used. 
N/A 
14.5.1.2 
In  item  a),  replace  IEC  60691  by  “IEC  60691  or 
JIS C 6691:2003”. 
 
N/A 
14.5.1.2 
In the first paragraph of item a), add “or Appendix 
3  of  the  Ministerial  Ordinance  on  stipulating 
technical requirements for the Electrical Appliance 
and Material
” after the reference” to the last of the 
sentence. 
 
N/A 
14.5.2.1 
Replace IEC 60127 by “IEC 60127 or JIS C 6575 
”. 
 
14.5.2.1 
In  the  first  paragraph,  add  “Appendix  3  of  the 
Ministerial  Ordinance  on  stipulating  technical 
requirements  for  the  Electrical  Appliance  and 
Material (limited to Fuses with the rated current of 
1  A  or  more),  or”  after  the  words,  ”shall  comply 
with”. 
 
14.5.2.2 
Add  the  following  paragraph  before  the  last 
paragraph. 
For  Fuses  according  to  Appendix  3  of  the 
Ministerial  Ordinance  on  stipulating  technical 
requirements  for  the  Electrical  Appliance  and 
Material,  only  the  rated  current  needs  to  be 
marked. 
 
14.5.3 
Replace  IEC  60730-1  by  JIS  C  9730-1 
(corresponding to IEC 60730-1).  
 
N/A 
14.5.4 
Replace IEC 60127 by “IEC 60127 or JIS C 6575 
”. 
 
N/A 
Page of 108