JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 76 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
ATTACHMENT TO TEST REPORT IEC 60065
JAPAN NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus - Safety requirements
Differences according to ...............:
IEC 60065:2001+amd.1:2005
Attachment Form No. ....................:
JP_ND_IEC60065J
Attachment Originator ...................:
UL Japan, Inc.
Master Attachment ........................:
2012-08
National Differences - Japan
1.1.3
Add the following as a NOTE after the first sentence.
NOTE 1 In Japan, the requirements for regions
with moderate apply.
with moderate apply.
P
2.4.9
In NOTE 1, replace “see 4.2.2 of IEC 62151” by
“see 4.2.2 of IEC 62151 [27]”.
“see 4.2.2 of IEC 62151 [27]”.
No TNV circuit
N/A
2.6.2A
Add this sub clause.
CLASS 0I EQUIPMENT: Equipment which has,
as for protection against electric shock,
as for protection against electric shock,
- at least using BASIC INSULATION, and
- providing a means of connecting to the
protective earthing conductor in the building
wiring those conductive parts that are
otherwise capable of assuming HAZARDOUS
VOLTAGES if the BASIC INSULATION fails,
and
wiring those conductive parts that are
otherwise capable of assuming HAZARDOUS
VOLTAGES if the BASIC INSULATION fails,
and
- using a supply cord without earthing conductor
and a plug without earthing wire although the
equipment has externally an earth terminal or
a lead wire for earthing.
equipment has externally an earth terminal or
a lead wire for earthing.
Equipment provided with a cord set having a two-
pin type plug with a lead wire for earthing or
having three pin - tow pin adaptor is also regarded
as Class 0I.
pin type plug with a lead wire for earthing or
having three pin - tow pin adaptor is also regarded
as Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
constructed with Double Insulation or Reinforced
Insulation.
Class II equipment
N/A
3.2
Add the “Class 0I equipment” in the first sentence
of this sub-clause.
of this sub-clause.
Added
P
3.2
Add the following after the first sentence of this
sub-clause.
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
should not be Class I equipment nor Class 0I
equipment.
Added
P
4.2.8
Delete this clause.
N/A
4.3.4, b)
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
P
4.3.12
Delete this clause.
N/A
Page 77 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
4.3.13
Replace “250 V a.c.” by “the maximum of the
variable range”.
variable range”.
P
5.4.2A
Add this sub-clause:
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
Example in Japanese:
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
Example in Japanese:
Class II equipment.
N/A
6.2
In NOTE 1, replace IEC 61040 [10] by JIS C
6181:1995 [10].
6181:1995 [10].
No laser.
N/A
7.1.5
Add the words, “without dimensions restrictions”
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
P
Page 78 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
7.1.5
Add the following paragraph as 2
nd
paragraph of
Condition “d “in Table 3.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements
for the Electrical Appliance and Material.
Permissible temperature rise of “Supply cords and
wiring insulation” is applicable only to the
materials used in supply cords complying with
JIS C 3662 (corresponding to IEC 60227) or JIS C
3663 (corresponding to IEC 60245). Materials
used in other wiring shall comply with item 3 of
detailed regulations, 1.(1).b, Appendix 4 in the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements
for the Electrical Appliance and Material.
Permissible temperature rise of “Supply cords and
wiring insulation” is applicable only to the
materials used in supply cords complying with
JIS C 3662 (corresponding to IEC 60227) or JIS C
3663 (corresponding to IEC 60245). Materials
used in other wiring shall comply with item 3 of
detailed regulations, 1.(1).b, Appendix 4 in the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material.
P
7.1.5
I
n the first paragraph of Condition “f” of Table 3,
add ”JIS K 7206:1999 or” before the reference,
ISO 306.
ISO 306.
P
7.1.5
In Condition “f,” 1) of Table 3, add ”JIS K
7206:1999 or” before the reference, ISO 306.
7206:1999 or” before the reference, ISO 306.
P
7.2
In NOTE 2, add ”or JIS standard” after the word,
IEC standard.
IEC standard.
P
8.5
In the first paragraph, add “and Class 0I
Equipment” after the words, Class I Equipment.
Equipment” after the words, Class I Equipment.
Not class I equipment.
N/A
8.5
In the six paragraph (before NOTE 3), add the
following to the end of the first sentence.
following to the end of the first sentence.
CLASS 0I EQUIPMENT shall be provided with a
protective earthing terminal in the external where
easily visible or a protective external earth wire
from mains plug.
protective earthing terminal in the external where
easily visible or a protective external earth wire
from mains plug.
N/A
8.11
In NOTE 2, c), add “or JIS C 2107, JIS C 2336,
JIS C 2338” after the reference, IEC 60454.
JIS C 2338” after the reference, IEC 60454.
P
9.1.1.1
In the last paragraph, add the following sentence
after the first sentence.
after the first sentence.
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0
mA.
CURRENT to earth shall not be more than 1.0
mA.
N/A
10
In NOTE, replace “IEC 60664-1 and IEC 60664-4
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4
[8]”
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4
[8]”
P
10.1
Add “CLASS 0I EQUIPMENT and” to the head of
the first paragraph.
the first paragraph.
N/A
10.3.2
In Table 5, add the following values to the sub-
table of NOTE.
table of NOTE.
P
Page 79 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Japan National Differences acc. to IEC 60065:2001 + A1
Operating
Voltage U (peak)
Test voltage (peak)
Curve A
Curve B
142 V
1 414 V
2 828 V
11.2.1
Add the following after the original NOTE.
NOTE
2
The
fuse
except
operating
characteristics specified in IEC 60127 shall be
tested in consideration of the characteristic.
tested in consideration of the characteristic.
P
11.2.3
Add “and CLASS 0I” after the words, CLASS I.
P
13.4
In NOTE 2 of Table 11, replace IEC 60664-1 by
JIS C 0664:2003 (corresponding to IEC 60664-1).
JIS C 0664:2003 (corresponding to IEC 60664-1).
P
14.3.3.2
In the second sentence of the first paragraph, add
“or JIS C 2107, JIS C 2336 and JIS C 2338” after
the reference, IEC 60454.
“or JIS C 2107, JIS C 2336 and JIS C 2338” after
the reference, IEC 60454.
P
14.5.1.1
In item a), add “JIS C 9730 series or” before the
reference, IEC 60730 series.
reference, IEC 60730 series.
No such component used.
N/A
14.5.1.2
In item a), replace IEC 60691 by “IEC 60691 or
JIS C 6691:2003”.
JIS C 6691:2003”.
N/A
14.5.1.2
In the first paragraph of item a), add “or Appendix
3 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance
and Material
3 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance
and Material
” after the reference” to the last of the
sentence.
N/A
14.5.2.1
Replace IEC 60127 by “IEC 60127 or JIS C 6575
”.
”.
P
14.5.2.1
In the first paragraph, add “Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material (limited to Fuses with the rated current of
1 A or more), or” after the words, ”shall comply
with”.
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material (limited to Fuses with the rated current of
1 A or more), or” after the words, ”shall comply
with”.
P
14.5.2.2
Add the following paragraph before the last
paragraph.
paragraph.
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, only the rated current needs to be
marked.
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, only the rated current needs to be
marked.
P
14.5.3
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
14.5.4
Replace IEC 60127 by “IEC 60127 or JIS C 6575
”.
”.
N/A
Click on the first or last page to see other CINEMA 610 service manuals if exist.