Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
 
APPENDIX  Canadian National Differences acc. to IEC 60065:2001 + Amd 1:2005 
3.2A 
[Add the following clause] 
A component power supply complying with 
CAN/CSA-C22.2 No. 60950 is considered to comply 
with this construction and fault conditions of this 
Standard after taking into account any relevant 
conditions of acceptability. Normal operating 
conditions 
 
N/A 
4.2.1 
[Add the following after the fifth paragraph] 
For apparatus Intended for use at nominal 120V ac, 
the apparatus shall comply with this Standard at 
supply voltages between 108 and 125V. For 
apparatus intended for use at nominal 240V ac, the 
apparatus shall comply with this Standard at supply 
voltages between 216 and 250V. 
 
4.2.10 
 
[Add the following after the second paragraph] 
As an alternative, a supply apparatus for general 
use complying with CAN/CSA-C22.2 No. 223 or 
CAN/CSA-022.2 No. 60950 shall be acceptable. 
 
N/A 
Marking and Instructions 
[Add the following paragraph] 
Adhesive nameplates on commercial products shall 
comply with CSA C22.2 No. 0.15. 5.1 
 
5.1 
Identification and supply ratings 
[Add the following item] 
hA) date of manufacture: a date or code identifying 
the period of manufacture shall be marked on the 
apparatus; 
 
5.3A 
 
[Add the following clause] 
Where a loudspeaker grille, removable from the 
outside, is relied on as part of the enclosure (see 
Clause 9.2), the following marking or equivalent shall 
be visible on the enclosure after removal of the grille: 
"Caution-To prevent electric shock hazard, replace 
grille." 
Alternatively, the symbol in Clause 5.2 b) shall be 
visible after removal of the grille, and the caution 
wording above shall appear in the user 
instructions, accompanied by the symbol. 
Compliance is checked by inspection. 
No such removable grille. 
N/A 
8.9 
 
 [Add the following title to this clause] 
Mains wiring 
[Add the following paragraph] 
Wiring in circuits with voltages higher than 42 V peak 
shall comply with CSA C22.2 No. 127 or CAN/CSA-
C22.2 No. 210.2.  
 
 
 
 
 
Page 65 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
9.1 
Testing on the outside 
 
9.1.1A  
Class I apparatus leakage 
[Add the following clause] 
For cord-connected Class I apparatus, the leakage 
current through the safety earthing conductor, 
expressed as voltages U and U , shall not exceed U 
=105V (peak) and U = 1.05V (peak) (1.5 mA). 1212 
Apparatus having a leakage current between 
0.75mA and 1.5mA shall be provided with a caution 
label on the mains cord with the following, or 
equivalent: 
"CAUTION -TO REDUCE THE RISK OF 
ELECTRIC SHOCK, GROUNDING OF THE 
CENTRE PIN OF THIS PLUG MUST BE 
MAINTAINED". 
Class II apparatus 
N/A 
9.1.1.2 
Determination of accessible parts 
[Add the following after the fourth paragraph] 
Moving parts of loudspeaker systems, such as 
dust caps, cones of drivers, or passive radiators, 
are not regarded as preventing accessibility. 
Note 1A: See also Clause 13.3.1. 
 
9.2 
Removal of protective covers 
[Add the following after the second paragraph] 
This requirement applies also to internal parts of 
loudspeaker systems that become accessible by 
removal of a loudspeaker grille from the outside 
either by hand or with the use of a tool, coin, or 
other object. In such cases, the apparatus shall be 
marked according to Clause 5.3A. 
(Replace the third paragraph with the following) 
Compliance is checked by inspections and by 
application of the tests of Clause 9.1.1, except that 
the measurements are made 2 after removal of the 
cover or grille. 
Considered.  No  removable 
grille. 
10.2A 
Enclosure type designation and use 
(Add the following clause] 
If equipment is installed in environments where the 
enclosure is required to prevent ingress of water or 
dust, the enclosure shall be classified as a type 
recognized by the Canadian Electrical Code, Part t, 
and shall comply with the requirements of CAN/CSA-
C22.2 No. 94. 
Indoor used only 
11.2 
Heating 
[Add the following paragraph] 
Flammable gases shall not be emitted from a 
component for more than 10 s.  
 
 
 
 
 
Page 66 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
12.3A.1 
 
 [Add the following clause] 
For television sets and similar apparatus using a 
cathode ray tube larger than 160 mm diagonally, the 
top, sides, front, and rear of the enclosure, including 
the safety screen where provided, shall be capable 
of withstanding a single impact of 7 J in accordance 
with Clause 12.3A.2 without developing any opening 
larger than 130 mm in the enclosure of the cathode 
ray tube, unless the minor dimension of 2 any 
opening is not more than 7 mm.When applied to a 
safety screen, the impact shall not result in damage 
to its mounting to the extent that it is mechanically 
unsuitable for reuse, nor shall tempered glass, if 
used, be cracked. 
When applied to the face of a directly viewed 
cathode ray tube, the impact shall not cause any 
opening in the face of the tube. 
Scaling and cracking of the glass shall be permissible. 
A cathode ray tube that has been shown to comply 
with CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965 
shall be considered acceptable with no further tests. 
No such apparatus 
N/A 
12.3A.2 
 [Add the following clause] 
The impact specified in Clause 12.3A.1 shall be 
caused by allowing a solid, smooth, steel sphere 51 
mm in diameter and weighing approximately 0.5 kg 
to strike the enclosure with the specified impact in a 
direction perpendicular to the enclosure surface. If 
deemed necessary, the enclosure shall be tested 
with the proper cathode ray tube mounted. 
 
13.3.1 
General 
[Add the following after the third paragraph] 
Clearances between a loudspeaker voice coil and 
adjacent conductive parts shall be disregarded. 
Not such distances apply.  
N/A 
14.2.1 
[Add the following paragraph] 
As an alternative, an isolating capacitor complying 
with the applicable requirements of CSA C22.2 No. I 
shall be acceptable for bridging basic or 
supplementary insulation 
(see appended table 14) 
14.2.2 
 [Add the following paragraph] 
As an alternative, an across-line capacitor complying 
with the applicable requirements of CSA C22.2 No. 1 
shall be acceptable. 
 
14.5.1.2 
 [Add the following paragraph] 
As an alternative, a thermal link complying with CSA 
C22.2 No. 209 shall be acceptable. 14.5.2 
 
N/A 
14.5.2.1 
 
 [Add the following paragraph] 
As an alternative, a fuse-link complying with CSA 
C22.2 No. 248.14 shall be acceptable. 
(see appended table 14) 
 
 
 
 
Page 67 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
14.5.2.4 
[Add the following paragraph] 
As an alternative, a fuse holder assembly complying 
with CSA C22.2 No. 39 shall be acceptable. 
Not used 
N/A 
14.6.1 
[Add the following paragraph] 
As an alternative, a TV-rated switch complying with 
CSA C22.2 No. 1, Clause 9, shall be acceptable. 
 
N/A 
14.6.2 
 
 [Add the following paragraph] 
As an alternative, a TV-rated switch complying with 
CSA C22.2 No. 1, Clause 9, shall be acceptable. 
 
N/A 
14.6.3 
 
 [Add the following paragraph] 
As an alternative, a TV-rated switch complying with 
CSA C22.2 No. 1, Clause 9, shall be acceptable. 
 
N/A 
14.6.4 
 
 [Add the following paragraph] 
As an alternative, a TV-rated switch complying with 
CSA C22.2 No. 1, Clause 9, shall be acceptable. 
 
N/A 
14.6.5 
 
[Add the following paragraph] 
As an alternative, a TV-rated switch complying with 
CSA C22.2 No. 1, Clause 9, shall be acceptable. 
 
N/A 
14.11 
Optocouplers 
[Add the following paragraph] 
As an alternative, an optocoupler complying with 
CSA C22.2 No. 1 shall be acceptable. 
 
14.12 
[Add the following paragraph] 
As an alternative, a varistor complying with CSA 
C22.2 No. 1 shall be acceptable. 14.12A Gas 
discharge tubes 
No varistor used. 
N/A 
14.12A 
[Add the following clause] 
Gas discharge tubes complying with the following 
tests may be connected to bridge basic or 
reinforced insulation. Ten samples of gas discharge 
tubes isolating the ac supply from exposed parts 
shall be subjected to the varistor pulse tests of 
Clause 14.12. Following the pulses, the device shall 
be allowed to return to room temperature. The 
dielectric breakdown voltage of the gas tube shall 
riot decrease by more than 50%, and the gas 
discharge tube shall comply with the dielectric 
strength test of Clause 10.3, with the test voltage 
reduced to twice the mains voltage. 
Not used 
N/A 