Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
APPENDIX Canadian National Differences acc. to IEC 60065:2001 + Amd 1:2005
P
3.2A
[Add the following clause]
A component power supply complying with
CAN/CSA-C22.2 No. 60950 is considered to comply
with this construction and fault conditions of this
Standard after taking into account any relevant
conditions of acceptability. Normal operating
conditions
CAN/CSA-C22.2 No. 60950 is considered to comply
with this construction and fault conditions of this
Standard after taking into account any relevant
conditions of acceptability. Normal operating
conditions
N/A
4.2.1
[Add the following after the fifth paragraph]
For apparatus Intended for use at nominal 120V ac,
the apparatus shall comply with this Standard at
supply voltages between 108 and 125V. For
apparatus intended for use at nominal 240V ac, the
apparatus shall comply with this Standard at supply
voltages between 216 and 250V.
the apparatus shall comply with this Standard at
supply voltages between 108 and 125V. For
apparatus intended for use at nominal 240V ac, the
apparatus shall comply with this Standard at supply
voltages between 216 and 250V.
P
4.2.10
[Add the following after the second paragraph]
As an alternative, a supply apparatus for general
use complying with CAN/CSA-C22.2 No. 223 or
CAN/CSA-022.2 No. 60950 shall be acceptable.
use complying with CAN/CSA-C22.2 No. 223 or
CAN/CSA-022.2 No. 60950 shall be acceptable.
N/A
5
Marking and Instructions
[Add the following paragraph]
Adhesive nameplates on commercial products shall
comply with CSA C22.2 No. 0.15. 5.1
comply with CSA C22.2 No. 0.15. 5.1
P
5.1
Identification and supply ratings
[Add the following item]
hA) date of manufacture: a date or code identifying
the period of manufacture shall be marked on the
apparatus;
the period of manufacture shall be marked on the
apparatus;
P
5.3A
[Add the following clause]
Where a loudspeaker grille, removable from the
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent shall
be visible on the enclosure after removal of the grille:
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent shall
be visible on the enclosure after removal of the grille:
"Caution-To prevent electric shock hazard, replace
grille."
grille."
Alternatively, the symbol in Clause 5.2 b) shall be
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
Compliance is checked by inspection.
No such removable grille.
N/A
8.9
[Add the following title to this clause]
Mains wiring
[Add the following paragraph]
Wiring in circuits with voltages higher than 42 V peak
shall comply with CSA C22.2 No. 127 or CAN/CSA-
C22.2 No. 210.2.
shall comply with CSA C22.2 No. 127 or CAN/CSA-
C22.2 No. 210.2.
P
Page 65 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
9.1
Testing on the outside
P
9.1.1A
Class I apparatus leakage
[Add the following clause]
For cord-connected Class I apparatus, the leakage
current through the safety earthing conductor,
expressed as voltages U and U , shall not exceed U
=105V (peak) and U = 1.05V (peak) (1.5 mA). 1212
current through the safety earthing conductor,
expressed as voltages U and U , shall not exceed U
=105V (peak) and U = 1.05V (peak) (1.5 mA). 1212
Apparatus having a leakage current between
0.75mA and 1.5mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:
0.75mA and 1.5mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:
"CAUTION -TO REDUCE THE RISK OF
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
Class II apparatus
N/A
9.1.1.2
Determination of accessible parts
[Add the following after the fourth paragraph]
Moving parts of loudspeaker systems, such as
dust caps, cones of drivers, or passive radiators,
are not regarded as preventing accessibility.
dust caps, cones of drivers, or passive radiators,
are not regarded as preventing accessibility.
Note 1A: See also Clause 13.3.1.
P
9.2
Removal of protective covers
[Add the following after the second paragraph]
This requirement applies also to internal parts of
loudspeaker systems that become accessible by
removal of a loudspeaker grille from the outside
either by hand or with the use of a tool, coin, or
other object. In such cases, the apparatus shall be
marked according to Clause 5.3A.
loudspeaker systems that become accessible by
removal of a loudspeaker grille from the outside
either by hand or with the use of a tool, coin, or
other object. In such cases, the apparatus shall be
marked according to Clause 5.3A.
(Replace the third paragraph with the following)
Compliance is checked by inspections and by
application of the tests of Clause 9.1.1, except that
the measurements are made 2 after removal of the
cover or grille.
Compliance is checked by inspections and by
application of the tests of Clause 9.1.1, except that
the measurements are made 2 after removal of the
cover or grille.
Considered. No removable
grille.
grille.
P
10.2A
Enclosure type designation and use
(Add the following clause]
If equipment is installed in environments where the
enclosure is required to prevent ingress of water or
dust, the enclosure shall be classified as a type
recognized by the Canadian Electrical Code, Part t,
and shall comply with the requirements of CAN/CSA-
C22.2 No. 94.
enclosure is required to prevent ingress of water or
dust, the enclosure shall be classified as a type
recognized by the Canadian Electrical Code, Part t,
and shall comply with the requirements of CAN/CSA-
C22.2 No. 94.
Indoor used only
P
11.2
Heating
[Add the following paragraph]
Flammable gases shall not be emitted from a
component for more than 10 s.
component for more than 10 s.
P
Page 66 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
12.3A.1
[Add the following clause]
For television sets and similar apparatus using a
cathode ray tube larger than 160 mm diagonally, the
top, sides, front, and rear of the enclosure, including
the safety screen where provided, shall be capable
of withstanding a single impact of 7 J in accordance
with Clause 12.3A.2 without developing any opening
larger than 130 mm in the enclosure of the cathode
ray tube, unless the minor dimension of 2 any
opening is not more than 7 mm.When applied to a
safety screen, the impact shall not result in damage
to its mounting to the extent that it is mechanically
unsuitable for reuse, nor shall tempered glass, if
used, be cracked.
cathode ray tube larger than 160 mm diagonally, the
top, sides, front, and rear of the enclosure, including
the safety screen where provided, shall be capable
of withstanding a single impact of 7 J in accordance
with Clause 12.3A.2 without developing any opening
larger than 130 mm in the enclosure of the cathode
ray tube, unless the minor dimension of 2 any
opening is not more than 7 mm.When applied to a
safety screen, the impact shall not result in damage
to its mounting to the extent that it is mechanically
unsuitable for reuse, nor shall tempered glass, if
used, be cracked.
When applied to the face of a directly viewed
cathode ray tube, the impact shall not cause any
opening in the face of the tube.
cathode ray tube, the impact shall not cause any
opening in the face of the tube.
Scaling and cracking of the glass shall be permissible.
A cathode ray tube that has been shown to comply
with CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965
shall be considered acceptable with no further tests.
A cathode ray tube that has been shown to comply
with CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965
shall be considered acceptable with no further tests.
No such apparatus
N/A
12.3A.2
[Add the following clause]
The impact specified in Clause 12.3A.1 shall be
caused by allowing a solid, smooth, steel sphere 51
mm in diameter and weighing approximately 0.5 kg
to strike the enclosure with the specified impact in a
direction perpendicular to the enclosure surface. If
deemed necessary, the enclosure shall be tested
with the proper cathode ray tube mounted.
caused by allowing a solid, smooth, steel sphere 51
mm in diameter and weighing approximately 0.5 kg
to strike the enclosure with the specified impact in a
direction perpendicular to the enclosure surface. If
deemed necessary, the enclosure shall be tested
with the proper cathode ray tube mounted.
P
13.3.1
General
[Add the following after the third paragraph]
Clearances between a loudspeaker voice coil and
adjacent conductive parts shall be disregarded.
adjacent conductive parts shall be disregarded.
Not such distances apply.
N/A
14.2.1
[Add the following paragraph]
As an alternative, an isolating capacitor complying
with the applicable requirements of CSA C22.2 No. I
shall be acceptable for bridging basic or
supplementary insulation
with the applicable requirements of CSA C22.2 No. I
shall be acceptable for bridging basic or
supplementary insulation
(see appended table 14)
P
14.2.2
[Add the following paragraph]
As an alternative, an across-line capacitor complying
with the applicable requirements of CSA C22.2 No. 1
shall be acceptable.
with the applicable requirements of CSA C22.2 No. 1
shall be acceptable.
P
14.5.1.2
[Add the following paragraph]
As an alternative, a thermal link complying with CSA
C22.2 No. 209 shall be acceptable. 14.5.2
C22.2 No. 209 shall be acceptable. 14.5.2
N/A
14.5.2.1
[Add the following paragraph]
As an alternative, a fuse-link complying with CSA
C22.2 No. 248.14 shall be acceptable.
C22.2 No. 248.14 shall be acceptable.
(see appended table 14)
P
Page 67 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
14.5.2.4
[Add the following paragraph]
As an alternative, a fuse holder assembly complying
with CSA C22.2 No. 39 shall be acceptable.
with CSA C22.2 No. 39 shall be acceptable.
Not used
N/A
14.6.1
[Add the following paragraph]
As an alternative, a TV-rated switch complying with
CSA C22.2 No. 1, Clause 9, shall be acceptable.
CSA C22.2 No. 1, Clause 9, shall be acceptable.
N/A
14.6.2
[Add the following paragraph]
As an alternative, a TV-rated switch complying with
CSA C22.2 No. 1, Clause 9, shall be acceptable.
CSA C22.2 No. 1, Clause 9, shall be acceptable.
N/A
14.6.3
[Add the following paragraph]
As an alternative, a TV-rated switch complying with
CSA C22.2 No. 1, Clause 9, shall be acceptable.
CSA C22.2 No. 1, Clause 9, shall be acceptable.
N/A
14.6.4
[Add the following paragraph]
As an alternative, a TV-rated switch complying with
CSA C22.2 No. 1, Clause 9, shall be acceptable.
CSA C22.2 No. 1, Clause 9, shall be acceptable.
N/A
14.6.5
[Add the following paragraph]
As an alternative, a TV-rated switch complying with
CSA C22.2 No. 1, Clause 9, shall be acceptable.
CSA C22.2 No. 1, Clause 9, shall be acceptable.
N/A
14.11
Optocouplers
[Add the following paragraph]
As an alternative, an optocoupler complying with
CSA C22.2 No. 1 shall be acceptable.
CSA C22.2 No. 1 shall be acceptable.
P
14.12
[Add the following paragraph]
As an alternative, a varistor complying with CSA
C22.2 No. 1 shall be acceptable. 14.12A Gas
discharge tubes
C22.2 No. 1 shall be acceptable. 14.12A Gas
discharge tubes
No varistor used.
N/A
14.12A
[Add the following clause]
Gas discharge tubes complying with the following
tests may be connected to bridge basic or
reinforced insulation. Ten samples of gas discharge
tubes isolating the ac supply from exposed parts
shall be subjected to the varistor pulse tests of
Clause 14.12. Following the pulses, the device shall
be allowed to return to room temperature. The
dielectric breakdown voltage of the gas tube shall
riot decrease by more than 50%, and the gas
discharge tube shall comply with the dielectric
strength test of Clause 10.3, with the test voltage
reduced to twice the mains voltage.
tests may be connected to bridge basic or
reinforced insulation. Ten samples of gas discharge
tubes isolating the ac supply from exposed parts
shall be subjected to the varistor pulse tests of
Clause 14.12. Following the pulses, the device shall
be allowed to return to room temperature. The
dielectric breakdown voltage of the gas tube shall
riot decrease by more than 50%, and the gas
discharge tube shall comply with the dielectric
strength test of Clause 10.3, with the test voltage
reduced to twice the mains voltage.
Not used
N/A