DOWNLOAD JBL CINEMA 610 Service Manual ↓ Size: 1.79 MB | Pages: 108 in PDF or view online for FREE

Model
CINEMA 610
Pages
108
Size
1.79 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cinema-610.pdf
Date

JBL CINEMA 610 EMC - CB Certificate ▷ View online

 
 
 
 
Page 68 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
15.1.1 
 
[Add the following paragraph] 
A receptacle provided for general purpose mains 
output shall comply with the requirements of CSA 
C22.2 No. 42 (dimensional requirements are also 
specified in IEC 60906-2). The attachment plug 
cap shall be of the polarized type when the 
apparatus is provided with a manually operated, 
mains-connected single-pole switch for apparatus 
on-off operation, a socket screwshell lampholder, 
or a 15 or 20 A socket-outlet. 
No such receptacle. 
N/A 
15.1.2 
 
 [Add the following paragraph] 
Banana plugs shall be acceptable. 
 
15.1.3 
 
 (Add the following title] 
Adapter output connectors 
[Replace the first paragraph with the following] 
Terminals and connectors used in output circuits of 
supply apparatus, whose output voltage is not a 
standard nominal mains voltage according to IEC 
60038, Table 1, shall not be compatible with those 
specified for household and similar general 
purposes, for example those described in IEC 60083 
[1], IEC 60320, IEC 60884, IEC 60906 (parts 1, 2, 
and 3), and CSA C22.2 No. 42. 
 
N/A 
15.2 
 
Provisions for protective earthing 
[Replace the third paragraph with the following] 
Earthing connections shall comply with the test 
requirements of CSA C22.2 No. 0.4. 
Class II equipment 
N/A 
15.3.1A 
 [Add the following clause] 
Equipment intended for permanent connection to the 
mains shall have provisions for connection to the 
wiring system in accordance with the Canadian 
Electrical Code, Part 1. 
The terminal parts and all other provisions for 
permanent connection to fixed wiring shall comply 
with CAN/CSA-C22.2 No. 0.  
 
N/A 
15.4.2 
 
 [Add the following paragraphs] 
Mains plugs of non-permanently installed equipment 
shall comply with 
a) CSA C22.2 No. 21 for moulded-on-type 
attachment plugs; and 
b) CSA C22.2 No. 42 for disassembly-type 
attachment plugs (dimensional requirements are 
also specified in IEC 60906-2). Class II 
equipment provided with a general purpose 
mains outlet, or a lampholder, shall be provided 
with a polarized-type plug. If the plug is a 
polarized type, single-pole switches or 
overcurrent protectors shall not be connected in 
the identified conductor. 
 
N/A 
 
 
 
 
Page 69 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
16.1 
 
 [Replace this clause with the following] 
Flexible cord used for mains supply shall comply 
with the requirements of CSA C22.2 No. 49. The 
cord type shall be in accordance with Table 4 of CSA 
C22.2 No. 1. 
The attachment plug shall be rated not less than 
125% of the apparatus rated current. Cord sets shall 
comply with the requirements of CSA C22.2 No. 21. 
Non-detachable flexible cables and cords of 
Class I apparatus shall be provided with a 
green/yellow core connected to the protective 
earthing terminal of the apparatus and, if a plug 
is provided, to the protective earthing contact 
of the plug. Compliance is checked by 
inspection. 
Note: The colour for cores of flexible mains cords is 
contained in /EC 60173 [4].  
(see appended table 14) 
17.9A.1 
Adhesive securement 
The following parts, the displacement of which may 
result in a fire or shock hazard, shall not be secured 
solely by adhesive, unless the adhesive system 
complies with the resistance to external forces test of 
Clause 9.1.7, the bump test of Clause 12.1.1, and 
the impact test of Clause 12.1.3, after conditioning in 
accordance with Clause 17.9A.2:  
a) internal metal parts/conductive coatings; 
b) barriers; and 
c) required enclosure parts. 
Note: Cathode ray tubes are excluded from this test. 
 
N/A 
17.9A.2.1   Where required by Clause 17.9A.1, one sample of the 
apparatus or enclosure section shall be conditioned in 
accordance with the requirements of Clause 
17.9A.2.2. Equivalent aging test data supplied by the 
manufacturer may be considered in lieu of aging.  
 
N/A 
 
 
 
 
Page 70 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
17.9A2.2 
Day 1: Place sample in oven at 100 ± 1EC for 1 
week, or 82 ± 1EC for 8 weeks, at the 
manufacturer’s option.  
Day 8 or day 57: 1. Remove from oven and leave 
at room temperature for 1 h. 2. Place in freezer at 
–35 EC for 2 h. 3. Remove from freezer and allow 
to reach room temperature overnight.  
Day 9 or day 58: 1. Place in a compartment at 
96% relative humidity for 3 h. 2. Remove and 
leave at room temperature and humidity for 1 h. 3. 
Place in oven at a temperature selected in the first 
cycle for 3 h. 4. Remove and allow to come to 
room temperature overnight.  
Day 10 or day 59: 1. Place in freezer at 
–35 EC for 
2 h. 2. Remove and leave at room temperature for 
1 h. 3. Place in humidity chamber at 96% relative 
humidity for 3 h. 4. Remove and allow to come to 
room temperature overnight.  
Day 11 or day 60: 1. Place in oven at the 
temperature selected in the first cycle for 3 h. 2. 
Remove for 1 h. 3. Place in freezer at 
–35 EC for 2 
h. 4. Remove and allow to come to room 
temperature overnight.  
Day 12 or day 61: 1. Place in humidity chamber at 
96% relative humidity for 3 h. 2. Remove and 
perform mechanical tests as required by Clause 
17.9A.1 as applicable. 
 
N/A 
18.1A 
Mechanical strength of picture tubes and 
protection against the effects of implosion 18.1A 
[Add the following clause] 
A picture tube with a maximum face dimension 
exceeding 75 mm either shall be intrinsically 
protected with respect to effects of implosion and 
to mechanical impact, In accordance with 
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965, or 
the enclosure of the apparatus shall provide 
adequate protection against the effects of an 
implosion of the tube (see Clause 12). 
 
N/A 
 
 
 
 
Page 71 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Canada National Differences acc. to IEC 60065:2001 + A1 
19 
[Add the following after the second 
paragraph] The test of Clause 19.3 is only 
required for a) apparatus with a mass of 25 kg 
or more; 
b) apparatus, excluding loudspeaker systems, with a 
height of 1 m or more; or 
c) Apparatus, including loudspeaker systems, in 
combination with a supplied or recommended cart or 
stand with a total height of 1 m or more. 
[Add the following paragraph] 
Apparatus not tested because it is intended to be 
fastened in place shall be provided with the following 
warning, marked on the apparatus or on a durable 
label attached to the mains cord: “WARNING: This 
apparatus must be securely attached to the floor/wall 
per installation instructions. Tipping, shaking, or 
rocking the machine may cause injury/death." 
 
N/A 
20.2.1A 
 
 [Add the following clause] 
Enclosures of apparatus containing high-voltage or 
projection lamps shall have a minimum flammability 
rating of category FV 1 according to IEC 60707 at the 
minimum thickness used. 
 
N/A 
Annex B 
(normative) 
Apparatus to be connected to the telecommunication 
networks 
[Replace this annex with the following] 
Apparatus intended for direct connection to a 
telecommunication network shall comply with  
a) Clause 19 of CSA C22.2 No. 1; or 
b) CAN/CSA-C22.2 No. 60950. 
 
N/A 
 
Page of 108
Display