JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 68 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
15.1.1
[Add the following paragraph]
A receptacle provided for general purpose mains
output shall comply with the requirements of CSA
C22.2 No. 42 (dimensional requirements are also
specified in IEC 60906-2). The attachment plug
cap shall be of the polarized type when the
apparatus is provided with a manually operated,
mains-connected single-pole switch for apparatus
on-off operation, a socket screwshell lampholder,
or a 15 or 20 A socket-outlet.
output shall comply with the requirements of CSA
C22.2 No. 42 (dimensional requirements are also
specified in IEC 60906-2). The attachment plug
cap shall be of the polarized type when the
apparatus is provided with a manually operated,
mains-connected single-pole switch for apparatus
on-off operation, a socket screwshell lampholder,
or a 15 or 20 A socket-outlet.
No such receptacle.
N/A
15.1.2
[Add the following paragraph]
Banana plugs shall be acceptable.
P
15.1.3
(Add the following title]
Adapter output connectors
[Replace the first paragraph with the following]
Terminals and connectors used in output circuits of
supply apparatus, whose output voltage is not a
standard nominal mains voltage according to IEC
60038, Table 1, shall not be compatible with those
specified for household and similar general
purposes, for example those described in IEC 60083
[1], IEC 60320, IEC 60884, IEC 60906 (parts 1, 2,
and 3), and CSA C22.2 No. 42.
supply apparatus, whose output voltage is not a
standard nominal mains voltage according to IEC
60038, Table 1, shall not be compatible with those
specified for household and similar general
purposes, for example those described in IEC 60083
[1], IEC 60320, IEC 60884, IEC 60906 (parts 1, 2,
and 3), and CSA C22.2 No. 42.
N/A
15.2
Provisions for protective earthing
[Replace the third paragraph with the following]
Earthing connections shall comply with the test
requirements of CSA C22.2 No. 0.4.
requirements of CSA C22.2 No. 0.4.
Class II equipment
N/A
15.3.1A
[Add the following clause]
Equipment intended for permanent connection to the
mains shall have provisions for connection to the
wiring system in accordance with the Canadian
Electrical Code, Part 1.
mains shall have provisions for connection to the
wiring system in accordance with the Canadian
Electrical Code, Part 1.
The terminal parts and all other provisions for
permanent connection to fixed wiring shall comply
with CAN/CSA-C22.2 No. 0.
permanent connection to fixed wiring shall comply
with CAN/CSA-C22.2 No. 0.
N/A
15.4.2
[Add the following paragraphs]
Mains plugs of non-permanently installed equipment
shall comply with
shall comply with
a) CSA C22.2 No. 21 for moulded-on-type
attachment plugs; and
attachment plugs; and
b) CSA C22.2 No. 42 for disassembly-type
attachment plugs (dimensional requirements are
also specified in IEC 60906-2). Class II
equipment provided with a general purpose
mains outlet, or a lampholder, shall be provided
with a polarized-type plug. If the plug is a
polarized type, single-pole switches or
overcurrent protectors shall not be connected in
the identified conductor.
attachment plugs (dimensional requirements are
also specified in IEC 60906-2). Class II
equipment provided with a general purpose
mains outlet, or a lampholder, shall be provided
with a polarized-type plug. If the plug is a
polarized type, single-pole switches or
overcurrent protectors shall not be connected in
the identified conductor.
N/A
Page 69 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
16.1
[Replace this clause with the following]
Flexible cord used for mains supply shall comply
with the requirements of CSA C22.2 No. 49. The
cord type shall be in accordance with Table 4 of CSA
C22.2 No. 1.
with the requirements of CSA C22.2 No. 49. The
cord type shall be in accordance with Table 4 of CSA
C22.2 No. 1.
The attachment plug shall be rated not less than
125% of the apparatus rated current. Cord sets shall
comply with the requirements of CSA C22.2 No. 21.
125% of the apparatus rated current. Cord sets shall
comply with the requirements of CSA C22.2 No. 21.
Non-detachable flexible cables and cords of
Class I apparatus shall be provided with a
green/yellow core connected to the protective
earthing terminal of the apparatus and, if a plug
is provided, to the protective earthing contact
of the plug. Compliance is checked by
inspection.
Class I apparatus shall be provided with a
green/yellow core connected to the protective
earthing terminal of the apparatus and, if a plug
is provided, to the protective earthing contact
of the plug. Compliance is checked by
inspection.
Note: The colour for cores of flexible mains cords is
contained in /EC 60173 [4].
contained in /EC 60173 [4].
(see appended table 14)
P
17.9A.1
Adhesive securement
The following parts, the displacement of which may
result in a fire or shock hazard, shall not be secured
solely by adhesive, unless the adhesive system
complies with the resistance to external forces test of
Clause 9.1.7, the bump test of Clause 12.1.1, and
the impact test of Clause 12.1.3, after conditioning in
accordance with Clause 17.9A.2:
result in a fire or shock hazard, shall not be secured
solely by adhesive, unless the adhesive system
complies with the resistance to external forces test of
Clause 9.1.7, the bump test of Clause 12.1.1, and
the impact test of Clause 12.1.3, after conditioning in
accordance with Clause 17.9A.2:
a) internal metal parts/conductive coatings;
b) barriers; and
c) required enclosure parts.
Note: Cathode ray tubes are excluded from this test.
N/A
17.9A.2.1 Where required by Clause 17.9A.1, one sample of the
apparatus or enclosure section shall be conditioned in
accordance with the requirements of Clause
17.9A.2.2. Equivalent aging test data supplied by the
manufacturer may be considered in lieu of aging.
accordance with the requirements of Clause
17.9A.2.2. Equivalent aging test data supplied by the
manufacturer may be considered in lieu of aging.
N/A
Page 70 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
17.9A2.2
Day 1: Place sample in oven at 100 ± 1EC for 1
week, or 82 ± 1EC for 8 weeks, at the
manufacturer’s option.
Day 8 or day 57: 1. Remove from oven and leave
at room temperature for 1 h. 2. Place in freezer at
–35 EC for 2 h. 3. Remove from freezer and allow
to reach room temperature overnight.
Day 9 or day 58: 1. Place in a compartment at
96% relative humidity for 3 h. 2. Remove and
leave at room temperature and humidity for 1 h. 3.
Place in oven at a temperature selected in the first
cycle for 3 h. 4. Remove and allow to come to
room temperature overnight.
Day 10 or day 59: 1. Place in freezer at
week, or 82 ± 1EC for 8 weeks, at the
manufacturer’s option.
Day 8 or day 57: 1. Remove from oven and leave
at room temperature for 1 h. 2. Place in freezer at
–35 EC for 2 h. 3. Remove from freezer and allow
to reach room temperature overnight.
Day 9 or day 58: 1. Place in a compartment at
96% relative humidity for 3 h. 2. Remove and
leave at room temperature and humidity for 1 h. 3.
Place in oven at a temperature selected in the first
cycle for 3 h. 4. Remove and allow to come to
room temperature overnight.
Day 10 or day 59: 1. Place in freezer at
–35 EC for
2 h. 2. Remove and leave at room temperature for
1 h. 3. Place in humidity chamber at 96% relative
humidity for 3 h. 4. Remove and allow to come to
room temperature overnight.
Day 11 or day 60: 1. Place in oven at the
temperature selected in the first cycle for 3 h. 2.
Remove for 1 h. 3. Place in freezer at
1 h. 3. Place in humidity chamber at 96% relative
humidity for 3 h. 4. Remove and allow to come to
room temperature overnight.
Day 11 or day 60: 1. Place in oven at the
temperature selected in the first cycle for 3 h. 2.
Remove for 1 h. 3. Place in freezer at
–35 EC for 2
h. 4. Remove and allow to come to room
temperature overnight.
Day 12 or day 61: 1. Place in humidity chamber at
96% relative humidity for 3 h. 2. Remove and
perform mechanical tests as required by Clause
17.9A.1 as applicable.
temperature overnight.
Day 12 or day 61: 1. Place in humidity chamber at
96% relative humidity for 3 h. 2. Remove and
perform mechanical tests as required by Clause
17.9A.1 as applicable.
N/A
18.1A
Mechanical strength of picture tubes and
protection against the effects of implosion 18.1A
protection against the effects of implosion 18.1A
[Add the following clause]
A picture tube with a maximum face dimension
exceeding 75 mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, In accordance with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
exceeding 75 mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, In accordance with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
N/A
Page 71 of 99
Report No.: 17032770 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
19
[Add the following after the second
paragraph] The test of Clause 19.3 is only
required for a) apparatus with a mass of 25 kg
or more;
paragraph] The test of Clause 19.3 is only
required for a) apparatus with a mass of 25 kg
or more;
b) apparatus, excluding loudspeaker systems, with a
height of 1 m or more; or
height of 1 m or more; or
c) Apparatus, including loudspeaker systems, in
combination with a supplied or recommended cart or
stand with a total height of 1 m or more.
combination with a supplied or recommended cart or
stand with a total height of 1 m or more.
[Add the following paragraph]
Apparatus not tested because it is intended to be
fastened in place shall be provided with the following
warning, marked on the apparatus or on a durable
label attached to the mains cord: “WARNING: This
apparatus must be securely attached to the floor/wall
per installation instructions. Tipping, shaking, or
rocking the machine may cause injury/death."
fastened in place shall be provided with the following
warning, marked on the apparatus or on a durable
label attached to the mains cord: “WARNING: This
apparatus must be securely attached to the floor/wall
per installation instructions. Tipping, shaking, or
rocking the machine may cause injury/death."
N/A
20.2.1A
[Add the following clause]
Enclosures of apparatus containing high-voltage or
projection lamps shall have a minimum flammability
rating of category FV 1 according to IEC 60707 at the
minimum thickness used.
projection lamps shall have a minimum flammability
rating of category FV 1 according to IEC 60707 at the
minimum thickness used.
N/A
Annex B
(normative)
(normative)
Apparatus to be connected to the telecommunication
networks
networks
[Replace this annex with the following]
Apparatus intended for direct connection to a
telecommunication network shall comply with
telecommunication network shall comply with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.
N/A