Report No.: 17032770 001 
 
IEC60065K - ATTACHMENT 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
J.2 
NO: After Table J.1 the following is added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
 
N/A 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) 
 
5.1 
 
IT: Additional markings on the outside of the TV 
receiver in Italian language 
No TV used. 
N/A 
 
IT:User instructions in Italian language including a 
conformity declaration 
 
N/A 
 
IT: Certification number on the back cover 
 
N/A 
6.1 
 
DE: The following requirement applies: 
For the operation of any cathode ray tube intended 
for the display of visual images operating at an 
acceleration voltage exceeding 40 kV, authorization 
is required, or application of type approval 
(Bauartzulassung) and marking. 
Justification: German ministerial decree against 
ionizing radiation (Röntgenverordnung), in force 
since 2002-07-01, implementing the European 
Directive 96/29/EURATOM.  
NOTE Contact address: 
 
N/A 
14 
 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification: Ordinance (1990:944) on Prohibition 
in Connection with handling. Importation and 
exportation of Chemical Products (Certain Cases) 
No such switch used. 
 
 
 
 
 
 
 
 
Page 57 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Australia National Differences acc. to IEC 60065:2001 + A1 + A2 
APPENDIX  Australia National Differences according to CB Bulletin 
(IEC Publication 60065 7th edition, 2001+ A1:2006+A2:2010) 
-- 
EXPLANATION FOR ABBREVIATIONS 
P=Pass, F=Fail, N/A=Not applicable.  Placed in the column to the right. 
ZZ.1 
Introduction 
This Annex sets out variations between this Standard 
and IEC 60065:2001.  These variations indicate 
national variations for purposes of the IECEE CB 
Scheme and will be published in the IECEE CB 
Bulletin.  These variations are indicated within the 
body of the Standard by shading and strikethrough. 
 
ZZ.2 
Variations 
The variations are as follows: 
 
7.1.5 
In table 3, under item c) add an 
h) 
in both columns 
against “thermoplastic materials’ and add the 
following new footnote: 
hAs an  alternative to the method described in 
footnote f) the following variation may be used 
where there is any doubt about the suitability of 
the material: 
The ball-pressure test described in AS/NZS 
60695.10.2 may be carried out. 
To assess compliance under normal operating 
conditions the test is made in a heating cabinet at 
a temperature of 40
2
C plus the maximum 
temperature rise determined under normal 
operating conditions but, it shall be at least 
for external parts.......................75
C
2
for materials supporting parts 
CONDUCTIVELY CONNECTED  
TO THE MAINS.............................125
C
2
Alternative method not 
applied. 
N/A 
7.2 
After the second paragraph, add the following: 
The alternative method described in footnote h) of 
Table 3 may be used. 
Alternative method not 
applied. 
N/A 
15.1.1 
After the second paragraph, add the following: 
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS 
3112 or AS/NZS 3123.  Apparatus with a plug portion, 
suitable for insertion into a 10A 3 pin flat-pin flat-pin 
socket-outlet complying with AS/NZS 3112, shall 
comply with the requirements of AS/NZS 3112 for 
equipment with integral pins for insertion into socket-
outlets. 
No such plugs provided. 
N/A 
15.3.5 
In Table 15, in the second and third rows of the first 
column replace “6” with “7.5”. 
Replaced. 
N/A 
 
 
 
 
Page 58 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Australia National Differences acc. to IEC 60065:2001 + A1 + A2 
16.2 
In Table 18, in the second and third rows of the first 
column replace “6” with “7.5”. 
 
N/A 
16.3 
After item (b) add the following: 
A flexible cord complying with AS/NZS 3191 need not 
undergo this test. 
Not provided. 
N/A 
19.201 
Add the following after Clause 19.6: 
19.201   Additional stability requirements for 
television receivers 
Television receivers and display devices that may be 
used for television purposes, with a mass of 7kg or 
more, shall have additional stability requirements.  
Compliance is checked by inspection and by the 
tests of 19.201.2.2 and 19.201.3 as applicable.  
Apparatus designed for only fixing to a wall, ceiling 
or equipment rack are not required to be subjected 
to these additional requirements if the marking of 
5.4.1 f) is provided on or with the apparatus. 
 
 
N/A 
 
19.201.1   Warning notice 
Television receivers and display devices that may be used for television purposes, 
shall be provided with information in the instructions for installation for use, 
containing the following information or similar: 
IMPORTANT INFORMATION 
If a television is not positioned in a sufficiently stable location, it can be potentially 
hazardous due to falling. Many injuries, particularly to children, can be avoided by taking 
simple precautions such as: 
 
Using cabinets or stands recommended by the manufacturer of the t elevision.  
 
Only using furniture that can safely support the television.  
 
Ensuring the television is not overhanging the edge of the supporting furniture.  
 
Not placing the television on tall furniture (for example, cupboards or bookcases)  
without anchoring both the furniture and the television to a suitable support.  
 
Not standing the televisions on cloth or other materials placed between the 
television  
and supporting furniture.  
 
Educating children about the dangers of climbing on furniture to reach the 
television  
or its controls. 
 
Such information should also be provided as a label on the apparatus. 
NOTE: The committee is considering a request from Regulatory Authorities that 
providing the information as a label on the apparatus should be mandatory. 
 
19.201.2   Restraining device 
19.201.2.1   Television receivers should be provided with a restraining device such 
as a fixing point to facilitate restraining the television from toppling forward. 
NOTE: The committee is considering a request from Regulatory Authorities that 
providing a restraining device on the apparatus should be mandatory. 
N/A 
 
 
 
 
Page 59 of 99 
 
 
 
Report No.: 17032770 001 
National Deviations 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
Australia National Differences acc. to IEC 60065:2001 + A1 + A2 
20 
Add the following after NOTE 2: 
For alternative test refer to Clause 20.201. 
Alternative tests not applied 
for. 
20.1.4 
In Table 21, in the third and fourth columns change 
both “HB75” and “No requirement” to “V-1”. 
Changed. 
20.2.3 
After this Clause, add the following variation: 
20.201 Resistance to fire - Alternative tests 
20.201.1 General 
Parts of non-metallic material shall be resistant to 
ignition and the spread of fire. 
This requirement does not apply to decorative trims, 
knobs and other parts unlikely to be ignited or to 
propagate flames originating from inside the 
apparatus, or the following: 
(a)  Components that are contained in an 
enclosure having a flammability category of 
V-0 according to AS/NZS 60695.11.10 and 
having openings only for the connecting wires 
filling the openings completely, and for 
ventilation not exceeding 1 mm in width 
regardless of length. 
(b)  The following parts which would contribute 
negligible fuel to a fire: 
-  small mechanical parts, the mass of 
which does not exceed 4g, such as 
mounting parts, gears, cams, belts and 
bearings; 
-  small electrical components, such as 
capacitors with a volume not exceeding 
1750mm
3
, integrated circuits, transistors 
and optocoupler packages, if these 
components are mounted on material of 
flammability category V-1 or better 
according to AS/NZS 60695.11.10 
Added, alternative tests not 
applied. 
 
N/A 
Page of 108