Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online
Page 23 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
N/A
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
The PCB has the flammability
rating of V-0
rating of V-0
Pass
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21
See components list
Pass
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltage exceeds 4kV.
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
1 mm in width and with openings for wires
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5
Marking and instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
Page 24 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No connected to the
telecommunication networks
telecommunication networks
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
The EUT is not such apparatus
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
Page 25 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 26 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
IEC 60065, 7th ed. + A1
(EN 60065: 2002 + A1: 2006)
GROUP DIFFERENCES, NATIONAL DEVIATIONS AND SPECIAL NATIONAL CONDITIONS IN THE
CENELEC COUNTRIES
C = CENELEC COMMON MODIFICATIONS
S = SPECIAL NATIONAL CONDITIONS
A = A-DEVIATIONS (NATIONAL DEVIATION
CENELEC COUNTRIES
C = CENELEC COMMON MODIFICATIONS
S = SPECIAL NATIONAL CONDITIONS
A = A-DEVIATIONS (NATIONAL DEVIATION
CONTENTS
C: Add the following annexes:
Annex ZA (normative) Other international
publications quoted in this standard with the
references of the relevant European publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
C: Add the following annexes:
Annex ZA (normative) Other international
publications quoted in this standard with the
references of the relevant European publications
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Pass
3.1
Add the following indent at the end of the list:
- exposure to excessive sound pressures from
headphones or earphones.
headphones or earphones.
NOTE A new method of measurement is described
in EN 50332-1, Sound system equipment:
in EN 50332-1, Sound system equipment:
Headphones and earphones associated with
portable audio equipment - Maximum sound
pressurelevel measurement methodology and limit
considerations - Part 1: General method for "one
package equipment”, and in EN 50332-2, Sound
system equipment: Headphones and earphones
portable audio equipment - Maximum sound
pressurelevel measurement methodology and limit
considerations - Part 1: General method for "one
package equipment”, and in EN 50332-2, Sound
system equipment: Headphones and earphones
associated with portable audio equipment -
Maximum sound pressure level measurement
methodology and limit considerations - Part 2:
Guidelines to associate sets with headphones
coming from different manufacturers.
Maximum sound pressure level measurement
methodology and limit considerations - Part 2:
Guidelines to associate sets with headphones
coming from different manufacturers.
Added
N/A
4.1.1
Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333.
50333.
Replaced
Pass
Click on the first or last page to see other HS 2X0 service manuals if exist.