DOWNLOAD Harman Kardon HS 2X0 Service Manual ↓ Size: 889.84 KB | Pages: 64 in PDF or view online for FREE

Model
HS 2X0
Pages
64
Size
889.84 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-2x0.pdf
Date

Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online

 
Page 23 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC60707, unless used in a fire enclosure  
 
N/A 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
The PCB has the flammability 
rating of V-0 
 
Pass 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the 
distances in Table 21 comply with the relevant 
flammability category in Table 21  
See components list 
Pass 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
No voltage exceeds 4kV. 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 N/A 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 
Marking and instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
 
Page 24 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS
 
 
Complies with IEC 62151 clause 1  
No connected to the 
telecommunication networks 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
The EUT is not such apparatus
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in Table 
 3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC 
60086-4  
 N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
 N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 N/A 
L. 14 
Components 
 
N/A 
 
Page 25 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 N/A 
 
 
Page 26 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
IEC 60065, 7th ed. + A1 
 
(EN 60065: 2002 + A1: 2006) 
 
GROUP DIFFERENCES, NATIONAL DEVIATIONS AND SPECIAL NATIONAL CONDITIONS IN THE 
CENELEC COUNTRIES 
 
C = CENELEC COMMON MODIFICATIONS 
 
S = SPECIAL NATIONAL CONDITIONS 
 
A = A-DEVIATIONS (NATIONAL DEVIATION
 
 
CONTENTS 
 
C: Add the following annexes: 
 
Annex ZA (normative) Other international 
publications quoted in this standard with the 
references of the relevant European publications 
 
Annex ZB (normative) Special national conditions 
 
Annex ZC (informative) A-deviations 
 Pass 
3.1 
Add the following indent at the end of the list: 
- exposure to excessive sound pressures from 
headphones or earphones. 
 
NOTE A new method of measurement is described 
in EN 50332-1, Sound system equipment: 
Headphones and earphones associated with 
portable audio equipment - Maximum sound 
pressurelevel measurement methodology and limit 
considerations - Part 1: General method for "one 
package equipment”, and in EN 50332-2, Sound 
system equipment: Headphones and earphones 
associated with portable audio equipment - 
Maximum sound pressure level measurement 
methodology and limit considerations - Part 2: 
Guidelines to associate sets with headphones 
coming from different manufacturers. 
Added  
N/A 
4.1.1 
Replace the text of the note by: 
 
NOTE For ROUTINE TEST reference is made to EN 
50333. 
Replaced  
Pass 
Page of 64
Display