Page 39 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
(cont.) 
 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the 
test voltage of 1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric 
strength during manufacturing, using a test 
voltage of 1,5 kV (for performance of the test 
see N.2.1). 
 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
 
A capacitor classified Y3 according to IEC 60384- 
14:1993, may bridge this insulation under the 
following conditions: 
 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 
testing, is tested with an Impulse test of 2.5 
kV defined in IEC 62151, subclause 6.2.1; 
- the additional testing shall be performed on 
all the test specimens as described in IEC 
60384-14; 
- the Impulse test of 2.5 kV is to be performed 
before the Endurance Test in IEC 60384-14 
in the sequence of tests as described in IEC 
60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
 
Add after the fourth dash: 
 
NOTE - In Norway, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals 
or other reliable means, and for equipment which 
is intended for connection to the building 
installation wiring via an industrial plug and 
socket -outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 N/A 
 
Page 40 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 
Sweden 
 
Replace NOTE 1 by 
 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 
62151). 
Subclause 4.1.1 (Corrigendum 2): 
 
Add after the first paragraph: 
 
NOTE - In Sweden, Class I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet. 
 
The marking text shall be as follows: 
 
“Apparaten skall anslutas till jordat uttag” 
Subclause 5.3.1 (Corrigendum 1): 
 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text 
is identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of 
which shall pass the electric strength test 
below, or 
- one layer having a distance through 
insulation of at least 0,4 mm, which shall 
pass the electric strength test below. 
 N/A 
 
Page 41 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
(cont.) 
 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in the 
accordance with the compliance clause below 
and in addition: 
 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the 
test voltage of 1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric 
strength during manufacturing, using a test 
voltage of 1,5 kV (for performance of the test 
see N.2.1). 
 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
 
A capacitor classified Y3 according to IEC 60384- 
14:1993, may bridge this insulation under the 
following conditions: 
 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 
testing, is tested with an Impulse test of 2.5 
kV defined in IEC 62151, subclause 6.2.1; 
- the additional testing shall be performed on 
all the test specimens as described in IEC 
60384-14; 
- the Impulse test of 2.5 kV is to be performed 
before the Endurance Test in IEC 60384-14 
in the sequence of tests as described in IEC 
60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
 
Add after the fourth dash: 
 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals 
or other reliable means, and for equipment which 
is intended for connection to the building 
installation wiring via an industrial plug and 
socket -outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 N/A 
 
Page 42 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Annex ZC (informative) 
 
A-deviations 
 
A-deviation: 
A national deviation due to regulations, the alteration of which 
− at least for the time being − 
outside the competence of the CEN/CENELEC member. 
5.1 
Italy 
 
The following requirements shall be fulfilled: 
- The power consumption in Watts (W) shall be 
indicated on TV receivers and in their instruction 
for use (Measurement according to EN 60555-2). 
NOTE EN 60555-2 has since been replaced by 
IEC 60107-1:1997. 
- TV receivers shall be provided with an 
instruction for use, schematic diagrams and 
adjustments procedure in Italian language. 
- Marking for controls and terminals shall be in 
Italian language. Abbreviation and international 
symbols are allowed provided that they are 
explained in the instruction for use. 
 
- The ECC manufacturers are bound to issue a 
conformity declaration according to the above 
requirements in the instruction manual. The 
correct statement for conformity to be written in 
the instruction manual, shall be: 
Questo apparecchio è fabbricato nella CEE nel 
rispetto delle disposizioni del D.M. marzo 1992 ed 
è in particolare conforme alle prescrizioni dell'art. 
1 dello stesso D.M. 
- The first importers of TV receivers manufactured 
outside EEC are bound to submit the TV 
receivers for previous conformity certification to 
the Italian Post Ministry (PP.TT). 
The TV receivers shall have on the backcover the 
certification number in the following form: 
 
D.M. 26/03/1992 xxxxx/xxxxx/S or T or pT 
 
S for stereo 
 
T for teletext 
 
pT for retrofitable teletext 
 
Justification: 
Ministerial Decree of 26 March 1992: National 
rules for television receivers trade. 
NOTE The ministerial decree above contains 
additional, but not safety relevant requirements. 
 N/A 