Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online
Page 43 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
6.1
Germany
The following requirement applies:
For the operation of any cathode ray tube
intended for the display of visual images
operating at an acceleration voltage exceeding
40 kV, authorization is required, or application of
type approval (Bauartzulassung) and marking.
Justification
The following requirement applies:
For the operation of any cathode ray tube
intended for the display of visual images
operating at an acceleration voltage exceeding
40 kV, authorization is required, or application of
type approval (Bauartzulassung) and marking.
Justification
:
German ministerial decree against ionizing
radiation (Röntgenverordnung), in force since
2002-07-01, implementing the European Directive
96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig,
Tel.: Int+49-531-592-6320, Internet:
http://www.ptb.de
N/A
14
Sweden
The following is added:
Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification:
Ordinance (1990:944) on Prohibition in
Connection with Handling, Importation and
Exportation of Chemical Products (Certain
Cases).
The following is added:
Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification:
Ordinance (1990:944) on Prohibition in
Connection with Handling, Importation and
Exportation of Chemical Products (Certain
Cases).
N/A
Page 44 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-
by ….………..:
by ….………..:
0W/1.4W max.
Position of the functional switch
(W) …………..……..:
(W) …………..……..:
On
—
Operating conditions
Normal DVD playing. Pink noise as audio input, 1/8 non-clipped power output to speaker, operates 4 hours until
steady condition reached.
steady condition reached.
Un (V)
In (A)
Pn (W)
Pout (W)
90 0.767 43.4 --
100 0.702 43.2
--
240 0.401 45.1
--
264 0.368 45.8
--
Loudspeaker impedance (Ω) ..................................: 6Ω X 2
—
Several loudspeaker systems
2 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
Monitored point:
dT (K)
Permitted dT (K)
Test voltage
90V 264V --
Power cord
18.0 18.4 50
Connector
22.0 25.2 -
PCB near RZ503
32.4 45.9 75
CY502 (Y1 capacitor)
20.3 22.1
40
(85-45)
CX503 (X2 capacitor )
28.7 32.5
40
(85-45)
Winding of LF501
26.4 32.2 65
PCB near BD501
31.2 29.1 75
PCB near Q509
18.0 18.4 75
PCB near U503
22.0 25.2 75
EC502 (electrolytic capacitor)
32.4 45.9
60
(105-45)
Winding of T502
20.3 22.1 65
Bobbin of T502
35.2 52.9 --
PCB near T502
28.7 32.5 75
CY504 (Y1 capacitor)
26.4 32.2
40
(85-45)
Winding of T503
31.2 29.1 65
Page 45 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Monitored point:
dT (K)
Permitted dT (K)
Bobbin of T503
36.5 31.5 --
PCB near T503
32.5 27.6 75
CY503 (Y1 capacitor)
31.2 27.5
40
(85-45)
PCB near D515
33.3 27.5 75
EC518 (electrolytic capacitor)
33.1 27.1
60
(105-45)
PCB of amplifier board
33.1 32.3 75
PCB of main board
31.6 30.7 75
Enclosure (metallic)
14.8 12.8 30
Enclosure (non-metallic)
6.4 6.1 50
Ambient
25.0 25.0 --
Supplementary information:
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100 2
Between parts separated by basic or supplementary insulation
100 2
Between parts separated by double or reinforced insulation
9.8 4
Between parts of T502 separated by basic or supplementary
insulation
insulation
100 2
Between parts of T503 separated by basic or supplementary
insulation
insulation
100 2
Note:
10.3
TABLE: electric strength measurements
Pass
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120Vp
No
Page 46 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Test voltage applied between:
Test voltage (V)
Breakdown
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of T502 separated by basic or supplementary
insulation
insulation
2542Vp
No
Between parts of T503 separated by basic or supplementary
insulation
insulation
2586Vp
No
Note:
11.2
TABLE: summary of fault condition tests
Pass
Voltage (V) 0,9 or 1,1 times rated voltage .............: 100-240V~
—
Ambient temperature (
o
C) .......................................: 25
—
No. Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse No.
Fuse
current
(A)
Result
Dielectric
strength test
after the test
after the test
1.
U502:
secondary
SC 264
10
min.
F501 0.063
P=1.7W. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
2.
R531
SC 264
10
min.
F501 0.062
P=1.5W. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
3.
D510
SC 264
10
min.
F501 0.124
P=10.5W max. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
4.
D512
SC 264
10
min.
F501 0.160
P=13.4W max. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
5.
D513
SC 264
10
min.
F501 0.142
P=12.0W. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
6.
D514
SC 264
10
min.
F501 0.162
P=13.2W. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
7.
EC506
SC 264
10
min.
F501 0.188
P=17.5W max. No high
temperature, no
hazard.
temperature, no
hazard.
Pass
8. EC511
SC 264
10
min.
F501 0.162
P=16.8W. D512
damaged, no high
temperature, no
hazard.
damaged, no high
temperature, no
hazard.
Pass
9. EC514
SC 264
15
min.
F501
0.241→
0.125
P=24.6W max.
P=13.6W min, 2
minutes, P=11.5. No
extreme high
temperature, no
hazard.
P=13.6W min, 2
minutes, P=11.5. No
extreme high
temperature, no
hazard.
Pass