DOWNLOAD Harman Kardon HS 2X0 Service Manual ↓ Size: 889.84 KB | Pages: 64 in PDF or view online for FREE

Model
HS 2X0
Pages
64
Size
889.84 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-2x0.pdf
Date

Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online

 
Page 43 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
6.1 
Germany 
 
The following requirement applies: 
 
For the operation of any cathode ray tube 
intended for the display of visual images 
operating at an acceleration voltage exceeding 
40 kV, authorization is required, or application of 
type approval (Bauartzulassung) and marking. 
 
Justification
 
German ministerial decree against ionizing 
radiation (Röntgenverordnung), in force since 
2002-07-01, implementing the European Directive 
96/29/EURATOM. 
 
NOTE Contact address: 
 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, 
 
Tel.: Int+49-531-592-6320, Internet: 
http://www.ptb.de 
 N/A 
14 
Sweden 
 
The following is added: 
 
Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
 
Justification: 
 
Ordinance (1990:944) on Prohibition in 
Connection with Handling, Importation and 
Exportation of Chemical Products (Certain 
Cases). 
 N/A 
 
 
                                                                       
Page 44 of 62                               Report No. SH10011244-001  
 
 
 
 
 
 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
7.1 
TABLE: temperature rise measurements 
Pass 
 
Power consumption in the OFF/Stand-
by ….………..: 
0W/1.4W max. 
 
 
Position of the functional switch 
(W) …………..……..: 
On 
— 
Operating conditions 
Normal DVD playing. Pink noise as audio input, 1/8 non-clipped power output to speaker, operates 4 hours until 
steady condition reached. 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
90 0.767 43.4  -- 
100 0.702 43.2 
-- 
240 0.401 45.1 
-- 
264 0.368 45.8 
-- 
 
 
Loudspeaker impedance (Ω) ..................................: 6Ω X 2 
— 
 
Several loudspeaker systems 
2 channel speakers 
Pass 
 
Marking of loudspeaker terminals 
Printed on rear enclosure 
Pass 
 
Monitored point: 
dT (K) 
Permitted dT (K) 
Test voltage 
90V 264V  -- 
Power cord 
18.0 18.4  50 
 
Connector  
22.0 25.2  - 
PCB near RZ503 
32.4 45.9  75 
CY502 (Y1 capacitor)  
20.3 22.1 
40 
(85-45) 
CX503 (X2 capacitor ) 
28.7 32.5 
40 
(85-45) 
Winding of LF501 
26.4 32.2  65 
PCB near BD501 
31.2 29.1  75 
PCB near Q509 
18.0 18.4  75 
PCB near U503 
22.0 25.2  75 
EC502 (electrolytic capacitor) 
32.4 45.9 
60 
(105-45) 
Winding of T502 
20.3 22.1  65 
Bobbin of T502 
35.2 52.9  -- 
PCB near T502 
28.7 32.5  75 
CY504 (Y1 capacitor)  
26.4 32.2 
40 
(85-45) 
Winding of T503 
31.2 29.1  65 
 
                                                                       
Page 45 of 62                               Report No. SH10011244-001  
 
 
 
 
 
 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Monitored point: 
dT (K) 
Permitted dT (K) 
Bobbin of T503 
36.5 31.5  -- 
PCB near T503 
32.5 27.6  75 
CY503 (Y1 capacitor)  
31.2 27.5 
40 
(85-45) 
PCB near D515 
33.3 27.5  75 
EC518 (electrolytic capacitor) 
33.1 27.1 
60 
(105-45) 
PCB of amplifier board 
33.1 32.3  75 
PCB of main board 
31.6 30.7  75 
Enclosure (metallic)  
14.8 12.8  30 
 
Enclosure (non-metallic) 
6.4 6.1 50 
Ambient 
25.0 25.0  -- 
Supplementary information: 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 2 
Between parts separated by basic or supplementary insulation
100 2 
Between parts separated by double or reinforced insulation 
9.8 4 
Between parts of T502 separated by basic or supplementary 
insulation 
100 2 
Between parts of T503 separated by basic or supplementary 
insulation 
100 2 
Note: 
 
 
10.3 
TABLE: electric strength measurements 
Pass 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120Vp 
No 
Between parts separated by basic or supplementary insulation
2120Vp 
No 
 
                                                                       
Page 46 of 62                               Report No. SH10011244-001  
 
 
 
 
 
 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Between parts separated by double or reinforced insulation 
4240Vp 
No 
Between parts of T502 separated by basic or supplementary 
insulation 
2542Vp 
No 
Between parts of T503 separated by basic or supplementary 
insulation 
2586Vp 
No 
Note: 
 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
 
Voltage (V) 0,9 or 1,1 times rated voltage .............: 100-240V~ 
— 
 
Ambient temperature (
o
C) .......................................: 25 
— 
 
No.  Component 
No. 
Fault 
Test 
voltage
(V) 
Test 
time 
Fuse No.
Fuse 
current
(A) 
Result 
Dielectric 
strength test 
after the test
1. 
U502: 
secondary   
     
SC 264 
10 
min. 
F501 0.063 
P=1.7W. No high 
temperature, no 
hazard.  
Pass 
2. 
R531       
SC 264 
10 
min. 
F501 0.062 
P=1.5W. No high 
temperature, no 
hazard.  
Pass 
3. 
D510      
SC 264 
10 
min. 
F501 0.124 
P=10.5W max. No high 
temperature, no 
hazard.  
Pass 
4. 
D512      
SC 264 
10 
min. 
F501 0.160 
P=13.4W max. No high 
temperature, no 
hazard.  
Pass 
5. 
D513       
SC 264 
10 
min. 
F501 0.142 
P=12.0W. No high 
temperature, no 
hazard.  
Pass 
6. 
D514      
SC 264 
10 
min. 
F501 0.162 
P=13.2W. No high 
temperature, no 
hazard.  
Pass 
7. 
EC506   
SC 264 
10 
min. 
F501 0.188 
P=17.5W max. No high 
temperature, no 
hazard.  
Pass 
8. EC511 
  SC 264 
10 
min. 
F501 0.162 
P=16.8W. D512 
damaged, no high 
temperature, no 
hazard.  
Pass 
9. EC514 
  SC 264 
15 
min. 
F501 
0.241→
0.125 
P=24.6W max. 
P=13.6W min, 2 
minutes, P=11.5. No 
extreme high 
temperature, no 
hazard. 
Pass 
Page of 64
Display