Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online
Page 35 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
Page 36 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex B
Finland
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Finland, Class I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
“Laite on liitettava suojamaadoituskoskettimilla
varustettuun pistorasiaan”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
- one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Finland, Class I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
“Laite on liitettava suojamaadoituskoskettimilla
varustettuun pistorasiaan”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
- one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
N/A
Page 37 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
(cont.)
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in the accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6
with an electric strength test of 10.3 using the
test voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric
strength during manufacturing, using a test
voltage of 1,5 kV (for performance of the test
see N.2.1).
It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
IEC 60384-14, which in addition to the Y3
testing, is tested with an Impulse test of 2.5
kV defined in IEC 62151, subclause 6.2.1;
- the additional testing shall be performed on
all the test specimens as described in IEC
60384-14;
- the Impulse test of 2.5 kV is to be performed
before the Endurance Test in IEC 60384-14
in the sequence of tests as described in IEC
60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals
or other reliable means, and for equipment which
is intended for connection to the building
installation wiring via an industrial plug and
socket -outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in the accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6
with an electric strength test of 10.3 using the
test voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric
strength during manufacturing, using a test
voltage of 1,5 kV (for performance of the test
see N.2.1).
It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
IEC 60384-14, which in addition to the Y3
testing, is tested with an Impulse test of 2.5
kV defined in IEC 62151, subclause 6.2.1;
- the additional testing shall be performed on
all the test specimens as described in IEC
60384-14;
- the Impulse test of 2.5 kV is to be performed
before the Endurance Test in IEC 60384-14
in the sequence of tests as described in IEC
60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals
or other reliable means, and for equipment which
is intended for connection to the building
installation wiring via an industrial plug and
socket -outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
N/A
Page 38 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Norway
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Norway, Class I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
"Apparatet skal tilkoples jordet stikkontakt"
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
- one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Norway, Class I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
"Apparatet skal tilkoples jordet stikkontakt"
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
- one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
N/A
Click on the first or last page to see other HS 2X0 service manuals if exist.