Page 15 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced 
insulation) ……………………...: 
T502 basic insulation minimum 
5.5 mm between T502 core and 
primary, Supplementary 
insulation minimum 4.5mm 
between T502 core and 
secondary. Reinforce insulation 
minimum 9.5mm between T502 
primary and secondary. 
T503 basic insulation minimum 
4.0 mm between T503 core and 
primary, Supplementary 
insulation minimum 4.0mm 
between T503 core and 
secondary. Reinforce insulation 
minimum 8.0mm between T503 
primary and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
Class II transformer. 
N/A 
14.3.4.3 
Separating transformers with at least basic insulation  
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 Pass 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
T502 basic insulation minimum 
5.5 mm between T502 core and 
primary, Supplementary 
insulation minimum 4.5mm 
between T502 core and 
secondary. Reinforce insulation 
minimum 9.5mm between T502 
primary and secondary. 
T503 basic insulation minimum 
4.0 mm between T503 core and 
primary, Supplementary 
insulation minimum 4.0mm 
between T503 core and 
secondary. Reinforce insulation 
minimum 8.0mm between T503 
primary and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
Class II transformer. 
N/A 
 
Page 16 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 N/A 
14.4 
High voltage components  
No such parts. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 N/A 
14.5 
Protective devices  
 
Pass 
 
Protective devices used within their ratings  
 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Fuse F501: 3.8mm 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved  
No such device within the EUT 
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
No such device within the EUT 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No such device within the EUT 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
F501 approved. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to 
holder ……: 
F501: T5A L 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel …………….: Soldered in the power board, 
only one location for fuse. 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ………..:
Tools required. 
 
Pass 
14.5.3 
PTC thermistors comply with IEC 60730-1  
No such device within the EUT 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
No such device within the EUT 
N/A  
14.6 Switches 
 
No such device within the EUT 
N/A  
14.6.1 a) 
Separate testing to IEC 61058 including: 
- 10 000 operations 
- Normal pollution suitability 
- Resistance to heat and fire level 3 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
 N/A 
 
Page 17 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
 
Switch controlling < 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1  
 N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
No such device within the EUT 
N/A 
 
Safety interlocks to 2.8 of IEC 60950  
 
N/A 
14.8 
Voltage setting devices and the like  
No such device within the EUT 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 N/A 
14.9 Motors 
No such device within the EUT 
N/A 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B  
 N/A 
14.10 Batteries 
 
Pass 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
Only non-rechargeable alkali 
batteries in IR remote controller.
Pass 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
No battery charging circuit 
within the remote controller 
N/A 
 
Page 18 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
14.10.3 
Recharging currents and times within manufacturers 
limits  
No rechargeable battery is 
provided 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 Optocouplers 
 
Approved 
optocoupler is used 
Pass 
 
Optocouplers comply with Cl. 8  
Internal DTI >0.40mm min. 
Pass 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation)  
int./ext. Cl. &Cr.  4mm min. / 
≥6.0mm min. 
Pass 
14.12 
Surge suppression varistors  
VDE approved 
Pass 
 
Comply with IEC 61051-2  
 
Pass 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 Pass 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved appliance inlet 
provided.                                
Pass 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
No mains socket outlet 
 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
No mains socket outlet 
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 Pass 
 
No risk of insertion in mains socket-outlets  
 
Pass 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2  
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 