Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online
Page 15 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced
insulation) ……………………...:
between hazardous live parts and accessible parts
(double or reinforced
insulation) ……………………...:
T502 basic insulation minimum
5.5 mm between T502 core and
primary, Supplementary
insulation minimum 4.5mm
between T502 core and
secondary. Reinforce insulation
minimum 9.5mm between T502
primary and secondary.
T503 basic insulation minimum
4.0 mm between T503 core and
primary, Supplementary
insulation minimum 4.0mm
between T503 core and
secondary. Reinforce insulation
minimum 8.0mm between T503
primary and secondary.
5.5 mm between T502 core and
primary, Supplementary
insulation minimum 4.5mm
between T502 core and
secondary. Reinforce insulation
minimum 9.5mm between T502
primary and secondary.
T503 basic insulation minimum
4.0 mm between T503 core and
primary, Supplementary
insulation minimum 4.0mm
between T503 core and
secondary. Reinforce insulation
minimum 8.0mm between T503
primary and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II transformer.
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
Pass
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T502 basic insulation minimum
5.5 mm between T502 core and
primary, Supplementary
insulation minimum 4.5mm
between T502 core and
secondary. Reinforce insulation
minimum 9.5mm between T502
primary and secondary.
5.5 mm between T502 core and
primary, Supplementary
insulation minimum 4.5mm
between T502 core and
secondary. Reinforce insulation
minimum 9.5mm between T502
primary and secondary.
T503 basic insulation minimum
4.0 mm between T503 core and
primary, Supplementary
insulation minimum 4.0mm
between T503 core and
secondary. Reinforce insulation
minimum 8.0mm between T503
primary and secondary.
4.0 mm between T503 core and
primary, Supplementary
insulation minimum 4.0mm
between T503 core and
secondary. Reinforce insulation
minimum 8.0mm between T503
primary and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer.
N/A
Page 16 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such parts.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Fuse F501: 3.8mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such device within the EUT
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
No such device within the EUT
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such device within the EUT
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
F501 approved.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to
holder ……:
holder ……:
F501: T5A L 250V
Pass
14.5.2.3
Not possible to connect fuses in parallel …………….: Soldered in the power board,
only one location for fuse.
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ………..:
replacing fuse-links without the use of a tool ………..:
Tools required.
Pass
14.5.3
PTC thermistors comply with IEC 60730-1
No such device within the EUT
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No such device within the EUT
N/A
14.6 Switches
No such device within the EUT
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
N/A
Page 17 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No such device within the EUT
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices and the like
No such device within the EUT
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
No such device within the EUT
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
14.10 Batteries
Pass
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
Only non-rechargeable alkali
batteries in IR remote controller.
batteries in IR remote controller.
Pass
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
No battery charging circuit
within the remote controller
within the remote controller
N/A
Page 18 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.10.3
Recharging currents and times within manufacturers
limits
limits
No rechargeable battery is
provided
provided
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
Approved
optocoupler is used
Pass
Optocouplers comply with Cl. 8
Internal DTI >0.40mm min.
Pass
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
int./ext. Cl. &Cr. 4mm min. /
≥6.0mm min.
Pass
14.12
Surge suppression varistors
VDE approved
Pass
Comply with IEC 61051-2
Pass
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
Pass
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
Pass
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Approved appliance inlet
provided.
provided.
Pass
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
No mains socket outlet
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket outlet
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
data
Pass
No risk of insertion in mains socket-outlets
Pass
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II
N/A
Protective earth conductors correctly coloured
N/A
Click on the first or last page to see other HS 2X0 service manuals if exist.