Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online
Page 11 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
9.1.7
Resistance to external forces
Pass
a) Test probe 11 of IEC 61032 for 10 s (50 N)
No damage of enclosure and no
hazardous live parts are
accessible.
hazardous live parts are
accessible.
Pass
b) Test hook of fig. 4 for 10 s (20 N)
No hazardous live parts are
accessible.
accessible.
Pass
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N
Pass
9.2
No hazard after removing a cover by hand
Tools required.
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ………………………………………………..
:
surge test for basic and 4 MΩ min. for reinforced
insulation ………………………………………………..
:
Pass
10.2
Humidity treatment 48 h or 120 h …………………….: 40℃, 95%, 120h.
Pass
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
Pass
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table)
Pass
11 Fault
conditions
11.1
No shock hazard under fault condition
Single fault did not cause
excessive voltage in output
circuits.
excessive voltage in output
circuits.
Pass
11.2
Heating under fault condition
Pass
Flames extinguish within 10 seconds
No flames
N/A
No hazard from softening solder
No softening of solder point and
becoming fluid
becoming fluid
Pass
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
(see appended table)
Pass
11.2.2
Temperature rise of accessible parts
(see appended table)
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
(see appended table)
Pass
Page 12 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than
2 cm² ………:
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than
2 cm² ………:
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
Class II
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table)
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
(see appended table)
Pass
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg
Mass weight : 3.53 kg.
Pass
12.1.2
Vibration test
N/A
12.1.3
Impact hammer test
0.5J, no hazards after the test
Pass
Steel ball test
2J, no hazards after the test
Pass
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
70°C / 7 hours
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
No remote control device with
hazardous live parts
hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawer is provided
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided as isolation
provided as isolation
N/A
12.6
Telescoping or rod antennas construction
No such device
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T502: 254Vrms, 536Vp
T503: 275Vrms, 560Vp
T503: 275Vrms, 560Vp
Pass
13.3 Clearances
Pass
13.3.1 General
Pass
Page 13 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table
9 …………..:
with table 8 and, where applicable, table
9 …………..:
(See table 13)
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Pass
Creepage distances greater than table 11 minimum
values
values
(See table 13)
Pass
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with 13.3
and 13.4
clearances and creepage distances comply with 13.3
and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and
creepage distances as in table 12
conductively connected to the mains, clearances and
creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Optocoupler are approved
components.
(See sub-clause 14.11)
components.
(See sub-clause 14.11)
Pass
14 Components
14.1 Resistors
Pass
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R
558
Pass
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ……………………….: R558 approved by VDE
Pass
14.2
Capacitors and RC units
Pass
Page 14 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Capacitors
separately
approved ………………...……:
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ……:
Y1: CY501, CY502, CY503,
CY504
CY504
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ……:
X2: CX501, CX502, CX503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for
X2 …………………:
connected to the mains: tests for
X2 …………………:
No such component.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or
better ………………:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or
better ………………:
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or
better ……………………………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or
better ……………………………………:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal …………………………………………………….
:
metal …………………………………………………….
:
No, electrolytic capacitor is fully
shielded by metal case.
shielded by metal case.
N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ……………………….:
manufacturer's name and type ……………………….:
Power transformer T502, T503
Line filter LF501, LF502
(See appended table14)
(See appended table14)
Pass
Transformers and inductors separately approved ….: No, tested with appliance
N/A
14.3.2 General
Pass
Insulation material complies with clause 20.1.4
Pass
14.3.3
Constructional requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
Pass
14.3.3.2
Transformers meet the constructional requirements
Pass
14.3.4
Separation between windings
Pass
Click on the first or last page to see other HS 2X0 service manuals if exist.