Page 19 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 
25 A ……………….: 
 N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
Appliance inlet used
 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board   N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 N/A 
 
Wire secured by additional means to the  
conductor   
 N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
         
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
         
 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
         
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 
         
 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
         
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
         
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
         
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
         
 N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
         
 N/A 
 
Page 20 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 
Terminals located and shielded: test with 8 mm 
strand  
 N/A 
15.4 
Devices forming a part of the mains plug  
 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
The EUT is not a direct plug-in 
apparatus 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber 
cords …………………………………………………….
PVC  
Pass 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Approved appliance inlet is 
provided 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
 Pass 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
No such kind of flexible cords 
used. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2) 
         
 N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
         
 N/A 
16.5 
Adequate strain relief on external flexible cords  
Approved appliance inlet is 
provided 
N/A 
 
Not possible to push cord back into equipment  
 N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
 N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement in 
use  
         
 
N/A 
 
Page 21 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
         
 N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
         
 N/A 
 
17 Electrical 
connections 
and mechanical fixings 
 
17.1 
Torque test to table 20  
 
Pass 
 
- screws into metal: 5 times  
Cover fixed 
Pass 
 
- screws into non-metallic material: 10 times  
Cover fixed 
Pass 
17.2 
Correct introduction into female threads in non-
metallic material  
 N/A 
17.3 
Cover fixing screws: captive  
Non-captive. 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
 
Pass 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
 Pass 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
 
Pass 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder  
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
No such device. 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
No such device. 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected  
All connectors are reliably 
secured 
Pass 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
 
Picture tube separately approved to IEC 
61965 …….: 
No picture tube.  
N/A 
 
Picture tube separately approved to 
18.1 ..…….…….: 
No N/A 
18.1 
Picture tubes >16 cm intrinsically protected  
 
N/A 
 
Non-intrinsically protected tubes >16 cm used with 
protective screen  
 N/A 
 
Page 22 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 
Protective film as part of implosion protection: edges 
covered by enclosure  
 N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples  
 
N/A 
18.2.1 
Samples subject to ageing: 6 samples  
 
N/A 
18.2.2 
Samples subject to implosion test: 6 samples  
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 samples  
 N/A 
18.3 Non-intrinsically 
protected tubes tested to 18.3  
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 
7 kg ..…………….: 
No, mass weight: 3.53 kg. 
N/A 
 
Apparatus intended to be fastened in place – 
suitable 
instructions ………………………………………….….:
No N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
         
 N/A 
19.2 
100 N force applied vertically downwards  
         
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability  
         
 N/A 
19.4 
Edges or corners not hazardous  
The outer surface of the EUT 
is smoothed. No sharp edges 
and corners 
Pass 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1  
No such glass surfaces. 
N/A 
19.6 
Wall or ceiling mountings adequate  
 
N/A 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
Pass 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 N/A 
 
b) Exemption for small components as defined in 
20.1  
Components are mounted on a 
PCB of V-0 
Pass 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4  
See components list 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
No voltage exceeds 4kV. 
N/A 