Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online
Page 7 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.4
Instructions for use
English version checked.
Versions of other languages will
be provided when submitted for
national approval.
Versions of other languages will
be provided when submitted for
national approval.
Pass
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The statement was provided in
manual.
manual.
Pass
b) Hazardous live terminals, instructions for wiring
No hazardous live terminal
N/A
c) Instructions for replacing lithium battery
No lithium battery
N/A
d) Class I earth connection warning
Class II
N/A
e) Instructions for multimedia system connection
Pass
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
N/A
h) Warning: protective film on CRT face
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
The statement was provided in
manual.
manual.
Pass
c) Instructions for permanently connected equipment
Not permanently connected
equipment.
equipment.
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
Pass
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
The EUT does not generate
ionizing radiation
ionizing radiation
N/A
Ionizing radiation under fault condition
See above
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 …….:
Class 1
Pass
Emission limits under fault
conditions ………………..:
conditions ………………..:
Laser Optical Pickup: Class 1
Pass
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
Page 8 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
Constructional requirements with regard to the protection against electric shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such components.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools required.
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
Pass
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the removal
of a cover which can be removed by hand
from parts rendered accessible following the removal
of a cover which can be removed by hand
The EUT is complied with the
requirements
requirements
Pass
8.5
Class I equipment
Class II
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
T502, T503, R558
Pass
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such components used.
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such components used.
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY501, CY502, CY503, CY504
Pass
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) ...:
N/A
Page 9 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Reinforced insulation > 0,4 mm (mm) ……………….: T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
Optocoupler U502, U504, U505,
U515: 0.40mm min.
U515: 0.40mm min.
Enclosure (front panel): 1.5mm
min.
Separation sheet on internal
enclosure around power board:
0.41mm min.
min.
Separation sheet on internal
enclosure around power board:
0.41mm min.
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Inside T502, T503.
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
N/A
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Pass
8.10
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Pass
8.11
Detaching of wires
No risk of any wire becoming
detached.
detached.
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
See above
Pass
Vibration test carried
out ………………………………:
out ………………………………:
No N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Pass
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Pass
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Internal wires secured and keep
enough distance from sharp or
hot parts.
enough distance from sharp or
hot parts.
Pass
Page 10 of 62 Report No. SH10011244-001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
The appliance coupler is used
as the disconnect device.
as the disconnect device.
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
No such device
N/A
8.19.2
Mains switch ON indication
Disconnect device is appliance
coupler
coupler
N/A
8.20
Switch not fitted in the mains cord
No such device
N/A
8.21
Bridging components comply with clause 14
No such device within the EUT
N/A
8.22
Non-separable thin sheet material
No such device within the EUT
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000Vac or 1500Vdc
1000Vac or 1500Vdc
N/A
9.1.1.1
a) Open circuit voltages
Pass
b) Touch current measured from terminal devices
using the network in
annex D …………………………:
using the network in
annex D …………………………:
U1=10.3Vp
U2=0.30Vp
U2=0.30Vp
Pass
c) Discharge not exceeding 45 μC
Less than 45
μC
Pass
d) Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers
Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No enter.
Pass
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Test probe did not become
hazardous live parts after test.
hazardous live parts after test.
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No such pre-set control used.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ………………:
of the mains plug; voltage (V) after 2 s ………………:
Less than the limit.
Discharging resistor
R501=R502=560 kΩ max
Discharging resistor
R501=R502=560 kΩ max
Pass
If C is not greater than 0,1 μF no test needed