Harman Kardon HS 2X0 EMC - CB Certificate ▷ View online

 
Page 7 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
5.4 
Instructions for use  
English version checked. 
Versions of other languages will 
be provided when submitted for 
national approval. 
Pass 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
The statement was provided in 
manual. 
Pass 
 
b) Hazardous live terminals, instructions for wiring   
No hazardous live terminal 
N/A 
 
c) Instructions for replacing lithium battery  
No lithium battery 
N/A 
 
d) Class I earth connection warning  
Class II 
N/A 
 
e) Instructions for multimedia system connection  
 
Pass 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
The statement was provided in 
manual. 
Pass 
 
c) Instructions for permanently connected equipment 
Not permanently connected 
equipment. 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 Pass 
 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
The EUT does not generate 
ionizing radiation 
N/A 
 
Ionizing radiation under fault condition  
See above 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 …….:
Class 1 
Pass 
 
Emission limits under fault 
conditions ………………..: 
Laser Optical Pickup: Class 1 
Pass 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
Pass 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
Pass 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
Pass 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table) 
Pass 
7.1.4 
Temperature rise of windings  
(see appended table) 
Pass 
 
Page 8 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
No such supporting parts 
N/A 
 
Constructional requirements with regard to the protection against electric shock
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
No such components. 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Tools required. 
Pass 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic material used 
Pass 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the removal 
of a cover which can be removed by hand  
The EUT is complied with the 
requirements 
Pass 
8.5 
Class I equipment  
Class II 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
 
Pass 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 
Pass 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
T502, T503, R558 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
No such components used. 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
No such components used. 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
CY501, CY502, CY503, CY504
Pass 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) ...:  
N/A 
 
Page 9 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
 
Reinforced insulation > 0,4 mm (mm) ……………….: T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min. 
Optocoupler U502, U504, U505, 
U515: 0.40mm min. 
Enclosure (front panel): 1.5mm 
min. 
Separation sheet on internal 
enclosure around power board: 
0.41mm min. 
Pass 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
Inside T502, T503. 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
Withstand 4240Vp test. 
Pass 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
 N/A 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
 N/A 
Double insulation between conductors connected to 
the mains and accessible parts.  
 Pass 
8.10 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
 Pass 
8.11 
Detaching of wires  
No risk of any wire becoming 
detached. 
Pass 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
See above 
Pass 
 
Vibration test carried 
out ………………………………: 
No N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 Pass 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 Pass 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
Internal wires secured and keep 
enough distance from sharp or 
hot parts. 
Pass 
 
Page 10 of 62                                Report No. SH10011244-001 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
 N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 
Disconnect device  
The appliance coupler is used 
as the disconnect device.
 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
No such device 
 
N/A 
8.19.2 
Mains switch ON indication  
Disconnect device is appliance 
coupler 
N/A 
8.20 
Switch not fitted in the mains cord  
No such device 
N/A 
8.21 
Bridging components comply with clause 14  
No such device within the EUT 
N/A 
8.22 
Non-separable thin sheet material  
No such device within the EUT 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 
1000Vac or 1500Vdc 
N/A 
9.1.1.1 
a) Open circuit voltages  
 
Pass 
 
b) Touch current measured from terminal devices 
using the network in 
annex D …………………………: 
U1=10.3Vp  
U2=0.30Vp 
Pass 
 
c) Discharge not exceeding 45 μC  
Less than 45
μC 
Pass 
 
d) Energy of discharge not exceeding 350 mJ  
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
Pass 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No enter. 
Pass 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Test probe did not become 
hazardous live parts after test. 
Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Test probe did not become 
hazardous live parts after test. 
Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No such pre-set control used. 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s ………………:
Less than the limit.    
Discharging resistor 
R501=R502=560 kΩ max 
Pass 
 
If C is not greater than 0,1 μF no test needed  
 N/A 
Page of 64