Page 53 of 56 
 
Report No.1018947 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex ZA 
Cont. 
 
 
 
Page 54 of 56 
 
Report No.1018947 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex ZB 
 
Annex ZB 
(normative) 
Special national conditions 
Special national condition: National characteristic or practice that cannot be 
changed even over a long period, e.g. climatic conditions, electrical earthing 
conditions. 
NOTE If it affects harmonization, it forms part of the European Standard. 
For the countries in which the relevant special national conditions apply these 
provisions are normative, for other countries they are informative. 
Add the following special national conditions: 
 
5.4 
 
Finland, Norway and Sweden 
To the end of 5.4 the following is added: 
CLASS I apparatus which is intended for connection 
to the building installation wiring via a plug or an 
appliance coupler, or both and in addition is 
intended for connection to other apparatus or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network TERMINALS and 
ACCESSIBLE parts, have a marking stating that the 
apparatus must be connected to an MAINS socket-
outlet with protective earth. 
The marking text in the applicable countries shall be 
as follows: 
In Finland: “Laite on liitettävä 
suojamaadoituskoskettimilla varustettuun 
pistorasiaan” 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: "Apparaten skall anslutas till jordat 
uttag" 
 N/A 
 
Page 55 of 56 
 
Report No.1018947 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
5.4.1 
Norway and Sweden  
To the end of 5.4.1 (after the compliance statement) 
the following is added:  
The screen of the cable distribution system is 
normally not earthed at the entrance of the building 
and there is normally no equipotential bonding 
system within the building. Therefore the protective 
earthing of the building installation need to be 
isolated from the screen of a cable distribution 
system.  
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer.  
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in:  
“Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing – and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)”  
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min.  
Translation to Norwegian (the Swedish text will also 
be accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr – og 
er tilkoplet et kabel-TV nett, kan forårsake 
brannfare. For å unngå dette skal det ved tilkopling 
av utstyret til kabel-TV nettet installeres en 
galvanisk isolator mellom utstyret og kabel-TV 
nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan utrustning och 
samtidigt är kopplad till kabel-TV nät kan i vissa fall 
medföra risk för brand.  
Főr att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät galvanisk isolator 
finnas mellan utrustningen och kabel-TV nätet.” 
 N/A 
Page 56 of 56 
 
Report No.1018947 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
15.1.1 
Denmark  
The text of the Danish SNC in EN 60065:2002 has 
been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase 
appliances having a rated current not exceeding 13 
A shall be provided with a plug according to the 
Heavy Current Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used 
in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with the 
Heavy Current Regulations, Section 107-2-D1 
standard sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to 
CLASS II apparatus with a rated current of 2,5 A 
shall be in accordance with the Heavy Current 
Regulation, Section 107-2-D1 standard sheet DKA 
1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or DKA 
1-3b.  
To the third paragraph the following is added:  
Mains socket-outlets with earthing contact shall be 
in compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a 
or DK 1-7a.  
Justification: Heavy Current Regulations, Section 
107-2-D1 
 N/A 
 