Harman Kardon HKTS 210SUB (serv.man7) EMC - CB Certificate ▷ View online
Test Report issued under the responsibility of
TEST REPORT
IEC 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Reference No......................: 1021750
Date of issue.....................................:
3 January 2011
Total number of pages .....................: See
below
CB Testing Laboratory...................: Intertek Semko AB
Address ............................................:
Box 1103, SE-164 22 Kista, SWEDEN
Applicant’s name............................: Harman Consumer, Inc.
Address ............................................: 8500
Balboa Blvd., Northridge, CA 91329, U.S.A.
Test specification:
Standard ...........................................:
IEC 60065:2001 + Amendment 1. Group- and national differences
for the CENELEC countries (EN 60065:2002 + A1 + A11)
for the CENELEC countries (EN 60065:2002 + A1 + A11)
Test procedure .................................:
CB Scheme
Non-standard test method…………..:
N/A
Test Report Form No......................:
IEC60065J
Test Report Form(s) Originator ........:
Intertek Semko AB
Master TRF.......................................: 2009-06
Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
scheme procedure shall be removed.
scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .....................:
Powered subwoofer
Trade Mark .......................................:
harman/kardon
Manufacturer ....................................: Harman Consumer Inc.
Model/Type reference ......................: HKTS210SUB/230
Ratings .............................................:
220-240V~, 50/60Hz, 200W, Class II
Modification to Test Report …………:
1018947
Modification on the appliance……….:
National differences for China, United Kingdom, South Korea, Australia
and also new critical components.
and also new critical components.
Clause Concerned …………….…….:
8.6, 8.8, 14.3.1, 14.3.4.1, 14.3.5.1, 14.6.1a , 7.1, 10.3, 11.2, 13, 14
Page 1 - 13
Relevant part of the IEC 60065 Test report.
Page 14 - 22
National differences for China, United Kingdom, South Korea and Australia
2 Photo pages
TEST REPORT issued by an Accredited Testing Laboratory. Accredited by Swedac, no 1003, ISO/IEC 17025
Page 3 of 22
Report No.1021750
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
8
Constructional requirements with regard to the protection against electric
shock
shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
P
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Transformer: T1, T2, alt. T2,
DT1, CT1
DT1, CT1
P
Components bridging double or reinforced
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
N/A
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY1, CY2, CY3, CY4
P
8.7
This clause is void
—
Cursive is for remarks about the update.
Page 4 of 22
Report No.1021750
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
8.8
Basic or supplementary insulation > 0.4 mm (mm)
.............................................................................. ...:
Primary wire supplementary
P
Reinforced insulation > 0.4 mm (mm) ....................: Bobbin: CT1
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
Transformer: DT1
Transformer: T2 F02801590(Tape)
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Transformer: T2 NT1758NL(Tape)
Transformer: T1 (TIW)
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N/A
Vibration test carried out .........................................: No,
no need, see above
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N
for 10 s)
for 10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
Cursive is for remarks about the update.