Harman Kardon HKTS 210SUB (serv.man7) EMC - CB Certificate ▷ View online
Page 9 of 22
Report No.1021750
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
13
TABLES: clearances and creepage distances
P
Rated supply voltage:
220-240V
Pollution degree:
2
Material Group:
IIIb
2 N force on internal parts applied:
P
30 N force on outside of conductive enclosure applied:
N/A
Location
Operating Voltage
Clearance (mm)
Creepage (mm)
V rms
V peak
Min
Actual
Min
Actual
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
Primary (ac) to Earth (B)
Primary (ac) to Earth (B)
-
-
-
-
-
-
Primary (+dc) to Earth max (B)
-
-
-
-
-
-
Primary (-dc) to Earth max (B)
-
-
-
-
-
-
Across mains fuse F1 (B)
240
339
2.0
2.2
2.4
4.1
Across primary directly connected to the
mains (B)
mains (B)
240 339 2.0
5.0
2.4 5.0
**Across primary directly connected to
the mains switch (R19) (B)
the mains switch (R19) (B)
240 339 2.0
>5.0
2.4
>5.0
Hazardous live secondary to Earth (B)
-
-
-
-
-
-
Optocoupler input to output (R)
240 (44*) 339 (83*)
0.8
5.3
2.2
5.3
Primary to Secondary in CT1 (R)
224 (124*) 339 (223*)
4.0
5.5
4.8
5.5
Primary to Secondary in T1 (R)
240 (130*)
358*
4.0
5.0
4.8
5.0
Primary to Secondary in ***T2 (R)
240 (178*) 339 (295*)
4.0
6.1
4.8
6.1
Primary to Secondary in DT1 (R)
240 (134*) 339 (257*)
4.0
5.9
4.8
5.9
Primary to accessible conductive parts (R)
240 339 4.0
5.5
4.8 5.5
**Primary to accessible conductive parts from
inside switch (R19) to rear panel (R)
inside switch (R19) to rear panel (R)
240 339 5.0
6.0
5.0
6.0
Primary to Secondary PWB (R)
240 (44*) 339 (83*)
4.0
5.4
4.8
5.4
Hazardous live secondary to non-
hazardous live secondary (R)
hazardous live secondary (R)
- - -
-
-
-
Hazardous live secondary to unearthed
conductive enclosure (R)
conductive enclosure (R)
- - -
-
-
-
Notes:
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal
input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna
signal input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9
unless the floating secondary circuit is separated from the primary circuits by an earthed metal screen (e.g. in the power
transformer), or the floating secondary circuit is connected to earth via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits
to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as
required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
"Actual = Actual dimensions measured.
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal
input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna
signal input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9
unless the floating secondary circuit is separated from the primary circuits by an earthed metal screen (e.g. in the power
transformer), or the floating secondary circuit is connected to earth via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits
to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as
required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
"Actual = Actual dimensions measured.
* measured operating voltage
**measurement on new switch (R19)
*** measurement on new transformer (F02801590)
**measurement on new switch (R19)
*** measurement on new transformer (F02801590)
Page 10 of 22 Report No.1021750
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Transformer T1
Ease House
Limited
NT1759NL
240V, 50/60Hz
Complies with
IEC 60065
Approved in
appliance
Insulating tape
Jingjiang Yahua
pressure
sensetive glue
Co., Ltd.
CT 4.5x0.05mm
130 °C
Approved in
appliance
Insulating tape
Suzhou
Mailaduona
Electric material
Co., Ltd.
JY312 8.5x0.05mm
130 °C
Approved in
appliance
Bobbin Material in
T1
Chang Chun
Plastics
Co., Ltd.
T375J
94V-0 150 °C
*Complies with
IEC 60707
V-1
Accepted in
appliance
Triple insulation
wire
Yong Chang
Silicone
Co., Ltd.
STW-B
130 °C
Complies with
IEC 60950
Accepted in
appliance
Triple insulation
wire
Dha Jin
Technology
Co., Ltd.
TLW-B
130 °C
Complies with
IEC 60950
Accepted in
appliance
Transformer T2
Ease House
Limited
NT1758NL
240V, 50/60Hz
Complies with
IEC 60065
Approved in
appliance
Insulating tape
Jingjiang Yahua
pressure
sensetive glue
Co., Ltd.
CT 11.0x0.05mm
130 °C
Approved in
appliance
Insulating tape
Suzhou
Mailaduona
Electric material
Co., Ltd.
JY312 22.0x0.05mm
130 °C
Approved in
appliance
Bobbin Material in
T2
Chang Chun
Plastics
Co., Ltd.
T375J
94V-0 150 °C
*Complies with
IEC 60707
V-1
Accepted in
appliance
Page 11 of 22 Report No.1021750
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
**Alternative
transformer T2
Just-For-You
Enterprise
Co., Ltd.
F02801590
240V, 50/60Hz
Complies with
IEC 60065
Approved in
appliance
**Insulating tape
(Mylar tape)
Chyun Yih Tape
Co., Ltd.
Or
Equal
P2xxF(b) 12.0mm
130 °C
Approved in
appliance
**Insulating tape
(Mylar tape)
Chyun Yih Tape
Co., Ltd.
Or
Equal
P2xxF(b) 22.0mm
130 °C
Approved in
appliance
**Bobbin Material
in T2
Chang Chun
Plastics
Co., Ltd.
Or
Equal
T375J
94V-0 150 °C
*Complies with
IEC 60707
V-1
Accepted in
appliance
Transformer DT1
Ease House
Limited
NT1670NL
240V, 50/60Hz
IEC 60065
Approved in
appliance
Insulating tape
Jingjiang Yahua
Pressure
Sensetive Glue
Co., Ltd.
CT 4.5x0.05mm
130 °C
Approved in
appliance
Insulating tape
Suzhou
Mailaduona
Electric material
Co., Ltd.
JY312 18.0x0.05mm
130 °C
Approved in
appliance
Bobbin Material in
DT1
Chang Chun
Plastics
Co., Ltd.
T375J
94V-0 150 °C
*Complies with
IEC 60707
V-1
Accepted in
appliance
Inductor CT1
Ease House
Limited
NT1669NL
240V, 50/60Hz
IEC 60065
Approved in
appliance
Bobbin Material in
CT1
Chang Chun
Plastics
Co., Ltd.
T375J
94V-0 150 °C
*Complies with
IEC 60707
V-1
Accepted in
appliance
Opto coupler (U2)
Cosmo Electronic
Corp
K1010 Dti=0.5mm,
int.dcr=5.3mm,
Ext.dcr=8.0mm,
100°C
IEC
60065
Opto coupler (U2)
Cosmo Electronic
Corp
KPC817 Dti=0.5mm,
int.dcr=5.3mm,
Ext.dcr=8.0mm,
100°C
IEC
60950
Capacitor CY4
To accessible
parts
Welson Industrial
Co.,Ltd
WD
1000p
F 250V
Y1
IEC 60384-14
2:nd Ed.
Page 12 of 22 Report No.1021750
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Capacitor CY2,
CY1
To accessible
parts
Welson Industrial
Co.,Ltd
WD 100ρF 250V Y1
IEC 60384-14
2:nd Ed.
Capacitor CY3
To accessible
parts
Welson Industrial
Co.,Ltd
WD
2200pF
250V Y1
IEC 60384-14
2:nd Ed.
PCB
Chih Hsien
Enterprise
Co., Ltd.
FR-1 KB-3150
Min.
94
V-0, 130
Degree C. 402
*Complies with
IEC 60707
V-1
Accepted in
appliance
PCB
Chih Hsien
Enterprise
Co., Ltd.
CEM-1
Min.
94
V-0, 130
Degree C. LS-50Z
*Complies with
IEC 60707
V-1
Accepted in
appliance
PCB
Gofortune
Technologies
Industrial
Co., Ltd.
FR-4
94V-01OZ S/S
1.6mm
*Complies with
IEC 60707
V-1
Accepted in
appliance
Shrinking tubing
Over mains
Switch
Dongguan
Quanti
Electronics
Co., Ltd.
T-2
600V, 125℃
VW - 1
*Complies with
IEC 60707
V-1
Accepted in
appliance
Alt. Changyuan
Electronics
(Shenzhen)
Co., Ltd.
CB-HFT
600V, 125℃
VW - 1
*Complies with
IEC 60707
V-1
Accepted in
appliance
Fuse F1
(miniature-type)
Ever Island
Electronic
Co.,Ltd
2010-Series
T4.0A, 250V
Complies with
IEC 60127-3
Connector CN1
House and base
Jowle
Technology
Co.,Ltd
A3963WV2
series
250V 7A max.
Suitable for 22-
18 AWG
Complies with
IEC 60065
clause 20.1.b
Accepted in
appliance
Thermistor (TH1)
In mains pole
Thinking
Electronic
Industrial
Co., Ltd.
SCK 048
120/240V
Complies with
IEC 60065
Accepted in
appliance
Varistor ZNR1
across mains
poles
Thinking
Electronic
Industrial
Co., Ltd.
TVR10471 470V IEC
61051
Capacitor CX1
across mains
poles
Europtronic
(Taiwan)
IND.Corp
MPX
0.33µF X2 275V
IEC 60384-14
2:nd Ed.
Alt. Farad
Electronics
Co., Ltd.
PXK
0.33µF X2 275V
IEC 60384-14
2:nd Ed.
Click on the first or last page to see other HKTS 210SUB (serv.man7) service manuals if exist.