DOWNLOAD Harman Kardon HKTS 210SUB (serv.man7) Service Manual ↓ Size: 921.79 KB | Pages: 22 in PDF or view online for FREE

Model
HKTS 210SUB (serv.man7)
Pages
22
Size
921.79 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-210sub-sm7.pdf
Date

Harman Kardon HKTS 210SUB (serv.man7) EMC - CB Certificate ▷ View online

Page 9 of 22 
                                        Report No.1021750 
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage: 
220-240V 
Pollution degree: 
Material Group: 
IIIb 
2 N force on internal parts applied: 
30 N force on outside of conductive enclosure applied: 
N/A 
Location 
Operating Voltage 
Clearance (mm) 
Creepage (mm) 
 
V rms 
V peak 
Min 
Actual 
Min 
Actual 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
Primary (ac) to Earth (B) 
Primary (+dc) to Earth max (B) 
Primary (-dc) to Earth max (B) 
Across mains fuse F1 (B) 
240 
339 
2.0 
2.2 
2.4 
4.1 
Across primary directly connected to the 
mains (B) 
240 339 2.0 
5.0 
2.4 5.0 
**Across primary directly connected to 
the mains switch (R19) (B) 
240 339 2.0 
>5.0 
2.4 
>5.0 
Hazardous live secondary to Earth (B) 
Optocoupler input to output (R) 
240 (44*)  339 (83*) 
0.8 
5.3 
2.2 
5.3 
Primary to Secondary in CT1 (R) 
224 (124*) 339 (223*)
4.0 
5.5 
4.8 
5.5 
Primary to Secondary in T1 (R) 
240 (130*)
358* 
4.0 
5.0 
4.8 
5.0 
Primary to Secondary in ***T2 (R) 
240 (178*) 339 (295*)
4.0 
6.1 
4.8 
6.1 
Primary to Secondary in DT1 (R) 
240 (134*) 339 (257*)
4.0 
5.9 
4.8 
5.9 
Primary to accessible conductive parts (R) 
240 339 4.0 
5.5 
4.8 5.5 
**Primary to accessible conductive parts from 
inside switch (R19) to rear panel (R) 
240 339 5.0 
6.0 
5.0 
6.0 
Primary to Secondary PWB (R) 
240 (44*)  339 (83*) 
4.0 
5.4 
4.8 
5.4 
Hazardous live secondary to non-
hazardous live secondary (R) 
- - - 
Hazardous live secondary to unearthed 
conductive enclosure (R) 
- - - 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal 
input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna 
signal input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9 
unless the floating secondary circuit is separated from the primary circuits by an earthed metal screen (e.g. in the power 
transformer), or the floating secondary circuit is connected to earth via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits 
to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as 
required, then the value for clearance is used as the minimum creepage distance . 
"Min" = minimum required. 
"Actual = Actual dimensions measured.
     
* measured operating voltage  
**measurement on new switch (R19) 
*** measurement on new transformer (F02801590)
Page 10 of 22                                          Report No.1021750 
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
14 
TABLE: list of critical components and materials 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Transformer T1 
Ease House 
Limited
 
NT1759NL 
240V, 50/60Hz 
Complies with 
IEC 60065 
Approved in 
appliance 
Insulating tape 
Jingjiang Yahua 
pressure 
sensetive glue 
Co., Ltd. 
CT 4.5x0.05mm 
130 °C 
 
Approved in 
appliance 
Insulating tape 
Suzhou 
Mailaduona 
Electric material 
Co., Ltd. 
JY312 8.5x0.05mm 
130 °C 
 
Approved in 
appliance 
Bobbin Material in 
T1 
Chang Chun 
Plastics  
Co., Ltd. 
T375J 
94V-0 150 °C 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Triple insulation 
wire 
Yong Chang 
Silicone  
Co., Ltd. 
STW-B 
130 °C 
Complies with   
IEC 60950 
Accepted in 
appliance 
Triple insulation 
wire 
Dha Jin 
Technology  
Co., Ltd. 
TLW-B 
130 °C 
Complies with   
IEC 60950 
Accepted in 
appliance 
Transformer T2 
Ease House 
Limited
 
NT1758NL 
240V, 50/60Hz 
Complies with 
IEC 60065 
Approved in 
appliance 
Insulating tape 
Jingjiang Yahua 
pressure 
sensetive glue 
Co., Ltd. 
CT 11.0x0.05mm 
130 °C 
 
Approved in 
appliance 
Insulating tape 
Suzhou 
Mailaduona 
Electric material 
Co., Ltd. 
JY312 22.0x0.05mm 
130 °C 
 
Approved in 
appliance 
Bobbin Material in 
T2 
Chang Chun 
Plastics  
Co., Ltd. 
T375J 
94V-0 150 °C 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Page 11 of 22                                          Report No.1021750 
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
**Alternative 
transformer T2 
Just-For-You 
Enterprise 
Co., Ltd.
 
F02801590 
240V, 50/60Hz 
Complies with 
IEC 60065 
Approved in 
appliance 
**Insulating tape 
(Mylar tape) 
Chyun Yih Tape 
Co., Ltd. 
Or 
Equal 
P2xxF(b) 12.0mm 
130 °C 
 
Approved in 
appliance 
**Insulating tape 
(Mylar tape) 
Chyun Yih Tape 
Co., Ltd. 
 Or 
Equal 
P2xxF(b) 22.0mm 
130 °C 
 
Approved in 
appliance 
**Bobbin Material 
in T2 
Chang Chun 
Plastics  
Co., Ltd. 
Or  
Equal 
T375J 
94V-0 150 °C 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Transformer DT1 
Ease House 
Limited
 
NT1670NL 
240V, 50/60Hz 
IEC 60065 
Approved in 
appliance 
Insulating tape 
Jingjiang Yahua 
Pressure 
Sensetive Glue 
Co., Ltd. 
CT 4.5x0.05mm 
130 °C 
 
Approved in 
appliance 
Insulating tape 
Suzhou 
Mailaduona 
Electric material 
Co., Ltd. 
JY312 18.0x0.05mm 
130 °C 
 
Approved in 
appliance 
Bobbin Material in 
DT1 
Chang Chun 
Plastics  
Co., Ltd. 
T375J 
94V-0 150 °C 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Inductor CT1 
Ease House 
Limited
 
NT1669NL 
240V, 50/60Hz 
IEC 60065 
Approved in 
appliance 
Bobbin Material in 
CT1 
Chang Chun 
Plastics  
Co., Ltd. 
T375J 
94V-0 150 °C 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Opto coupler (U2) 
Cosmo Electronic 
Corp
 
K1010 Dti=0.5mm, 
int.dcr=5.3mm,
Ext.dcr=8.0mm,
100°C 
 IEC 
60065 
 
 
Opto coupler (U2) 
Cosmo Electronic 
Corp
 
KPC817 Dti=0.5mm, 
int.dcr=5.3mm,
Ext.dcr=8.0mm,
100°C 
 IEC 
60950 
 
 
Capacitor CY4 
To accessible 
parts  
Welson Industrial 
Co.,Ltd
 
WD 
1000p
 F 250V 
Y1 
IEC 60384-14 
2:nd Ed. 
 
Page 12 of 22                                          Report No.1021750 
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Capacitor  CY2, 
CY1 
To accessible 
parts 
Welson Industrial 
Co.,Ltd
 
WD 100ρF 250V Y1
IEC 60384-14 
2:nd Ed. 
 
Capacitor CY3 
To accessible 
parts 
Welson Industrial 
Co.,Ltd
 
WD 
2200pF
 250V Y1
IEC 60384-14 
2:nd Ed. 
 
PCB 
Chih Hsien 
Enterprise  
Co., Ltd. 
FR-1 KB-3150
 
Min. 
94
V-0, 130 
Degree C. 402
 
*Complies with 
IEC 60707 
V-1 
Accepted in 
appliance 
PCB 
Chih Hsien 
Enterprise  
Co., Ltd. 
CEM-1 
 
Min. 
94
V-0, 130 
Degree C. LS-50Z
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
PCB 
Gofortune 
Technologies 
Industrial  
Co., Ltd. 
FR-4 
 
94V-01OZ S/S 
1.6mm
 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Shrinking tubing 
Over mains 
Switch 
Dongguan 
Quanti 
Electronics  
Co., Ltd. 
T-2 
600V, 125℃ 
VW - 1 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Alt. Changyuan 
Electronics 
(Shenzhen) 
Co., Ltd. 
CB-HFT  
600V, 125℃ 
VW - 1 
*Complies with   
IEC 60707 
V-1 
Accepted in 
appliance 
Fuse F1 
(miniature-type) 
Ever Island 
Electronic 
Co.,Ltd 
2010-Series 
 
T4.0A, 250V 
Complies with  
IEC 60127-3  
 
Connector CN1 
House and base 
Jowle 
Technology 
Co.,Ltd 
A3963WV2 
series 
 
250V 7A max.   
Suitable for 22-
18 AWG 
Complies with 
IEC 60065 
clause 20.1.b 
Accepted in 
appliance 
Thermistor (TH1) 
In mains pole 
Thinking 
Electronic 
Industrial  
Co., Ltd. 
SCK 048 
120/240V 
Complies with 
IEC 60065 
Accepted in 
appliance 
Varistor ZNR1 
across mains 
poles 
Thinking 
Electronic 
Industrial  
Co., Ltd. 
TVR10471 470V  IEC 
61051 
 
 
 
Capacitor CX1 
across mains 
poles 
Europtronic 
(Taiwan) 
IND.Corp 
MPX 
0.33µF X2 275V
IEC 60384-14 
2:nd Ed. 
 
 
Alt. Farad 
Electronics  
Co., Ltd. 
PXK 
0.33µF X2 275V
IEC 60384-14 
2:nd Ed. 
 
 
Page of 22
Display