Report No.1021750
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
20.2.3
Cont.
NOTE 1 – If the enclosure does not withstand the glow-
wire test the appliance is considered to have failed to
meet the requirements of Clause 21.201 without the
need for consequential testing.
NOTE 2 – If other parts do not withstand the glow-wire
test due to ignition of the tissue paper and if this
indicates that burning or glowing particles can fall onto
an external surface underneath the apparatus, the
apparatus is considered to have failed to meet the
requirements of Clause 21.201 without the need for
consequential testing
NOTE 3 – Parts likely to be impinged upon by the
flame are considered to be those within the envelope of
a vertical cylinder having a radius of 10 mm and a
height equal to the height of the flame, positioned
above the point of the material supporting, in contact
with, or in close proximity to, connections.
wire test the appliance is considered to have failed to
meet the requirements of Clause 21.201 without the
need for consequential testing.
NOTE 2 – If other parts do not withstand the glow-wire
test due to ignition of the tissue paper and if this
indicates that burning or glowing particles can fall onto
an external surface underneath the apparatus, the
apparatus is considered to have failed to meet the
requirements of Clause 21.201 without the need for
consequential testing
NOTE 3 – Parts likely to be impinged upon by the
flame are considered to be those within the envelope of
a vertical cylinder having a radius of 10 mm and a
height equal to the height of the flame, positioned
above the point of the material supporting, in contact
with, or in close proximity to, connections.
20.201.2.4 Testing of printed boards
The base material of printed boards shall be subject to
the needle-flame test of Clause 21.201.2.3. The flame
shall be applied to the edge of the board where the
heatsink effect is lowest when the board is positioned
as in normal use. The flame shall not be applied to an
edge consisting of broken perforations, unless the
edge is less than 3 mm from a potential ignition source.
The test is not carried out if the—
- printed board does not carry any potential ignition
source;
- base material of printed boards, on which the
available power at a connection exceeds 15 VA
operating at a voltage exceeding 50 V and equal or
less than 400 V (peak) a.c. or d.c. under normal
operating conditions, is of flammability category V-1 or
better according to AS/NZS 60695.11.10, or the
printed boards are protected by an enclosure meeting
the flammability category V-0 according to
AS/NZS 60695.11.10, or made of metal, having
openings only for connecting wires which fill the
openings completely; or
The base material of printed boards shall be subject to
the needle-flame test of Clause 21.201.2.3. The flame
shall be applied to the edge of the board where the
heatsink effect is lowest when the board is positioned
as in normal use. The flame shall not be applied to an
edge consisting of broken perforations, unless the
edge is less than 3 mm from a potential ignition source.
The test is not carried out if the—
- printed board does not carry any potential ignition
source;
- base material of printed boards, on which the
available power at a connection exceeds 15 VA
operating at a voltage exceeding 50 V and equal or
less than 400 V (peak) a.c. or d.c. under normal
operating conditions, is of flammability category V-1 or
better according to AS/NZS 60695.11.10, or the
printed boards are protected by an enclosure meeting
the flammability category V-0 according to
AS/NZS 60695.11.10, or made of metal, having
openings only for connecting wires which fill the
openings completely; or
21. . base material of printed boards, on which
the available power at a connection
exceeds 15 VA
exceeds 15 VA
operating at a voltage exceeding 400 V (peak) a.c. or
d.c. under normal operating conditions, and base
material of printed boards supporting spark gaps which
provides protection against overvoltages, is of
flammability category V-0 according to AS/NZS
60695.11.10 or the printed boards are contained in a
enclosure, having openings only for connecting wires
which fill the openings completely.
Compliance shall be determined using the smallest
thickness of the material.
NOTE – Available power is the maximum power which
can be drawn from the supplying circuit through a
resistive load whose value is chosen to maximize the
power for more than 2 min when the circuit supplied is
disconnected.
category V-1 or better according to AS/NZS
60695.11.10.
d.c. under normal operating conditions, and base
material of printed boards supporting spark gaps which
provides protection against overvoltages, is of
flammability category V-0 according to AS/NZS
60695.11.10 or the printed boards are contained in a
enclosure, having openings only for connecting wires
which fill the openings completely.
Compliance shall be determined using the smallest
thickness of the material.
NOTE – Available power is the maximum power which
can be drawn from the supplying circuit through a
resistive load whose value is chosen to maximize the
power for more than 2 min when the circuit supplied is
disconnected.
category V-1 or better according to AS/NZS
60695.11.10.
N/A
Page 22 of 22
Report No.1021750
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
20.2.3
Cont.
21.201.3 For open circuit voltages greater than 4 kV
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
N/A
Annex B
After the heading add:
For Australia only, this Annex is replaced by the
requirements of the Telecommunications Labelling
Notice issued under the Telecommunications Act.
NOTE – The Telecommunications Act is administered
by the Australian Communications Authority.
For Australia only, this Annex is replaced by the
requirements of the Telecommunications Labelling
Notice issued under the Telecommunications Act.
NOTE – The Telecommunications Act is administered
by the Australian Communications Authority.
N/A
Note: the requirements in “Amendment 1 to AS/NZS 60065:2003” have all been
checked and found to be “N/A” for this product.
checked and found to be “N/A” for this product.
Page 22 of 22
Report No.1021750
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
20.2.3
Cont.
21.201.3 For open circuit voltages greater than 4 kV
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
N/A
Annex B
After the heading add:
For Australia only, this Annex is replaced by the
requirements of the Telecommunications Labelling
Notice issued under the Telecommunications Act.
NOTE – The Telecommunications Act is administered
by the Australian Communications Authority.
For Australia only, this Annex is replaced by the
requirements of the Telecommunications Labelling
Notice issued under the Telecommunications Act.
NOTE – The Telecommunications Act is administered
by the Australian Communications Authority.
N/A
Note: the requirements in “Amendment 1 to AS/NZS 60065:2003” have all been
checked and found to be “N/A” for this product.
checked and found to be “N/A” for this product.
Page 22 of 22
Report No.1021750
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
20.2.3
Cont.
21.201.3 For open circuit voltages greater than 4 kV
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
N/A
Annex B
After the heading add:
For Australia only, this Annex is replaced by the
requirements of the Telecommunications Labelling
Notice issued under the Telecommunications Act.
NOTE – The Telecommunications Act is administered
by the Australian Communications Authority.
For Australia only, this Annex is replaced by the
requirements of the Telecommunications Labelling
Notice issued under the Telecommunications Act.
NOTE – The Telecommunications Act is administered
by the Australian Communications Authority.
N/A
Note: the requirements in “Amendment 1 to AS/NZS 60065:2003” have all been
checked and found to be “N/A” for this product.
checked and found to be “N/A” for this product.