Harman Kardon HKTS 210SUB (serv.man3) EMC - CB Certificate ▷ View online
Test report no. 1018989E
Page 2 (13)
CONTENTS
Page
1.Client information .................................................................................................................. 3
2.Equipment under test (EUT) ................................................................................................. 3
2.1 Identification of the EUT.............................................................................................. 3
2.2 Additional information about the EUT ......................................................................... 3
2.2 Additional information about the EUT ......................................................................... 3
3.Test specifications................................................................................................................. 4
3.1 Standards.................................................................................................................... 4
3.2 Additions, deviations and exclusions from standards and accreditation .................... 4
3.3 Mode of operation during the test ............................................................................... 4
3.2 Additions, deviations and exclusions from standards and accreditation .................... 4
3.3 Mode of operation during the test ............................................................................... 4
4.Test summary........................................................................................................................ 5
5. Mains terminal continuous disturbance voltage ................................................................... 6
5.1 Operating environment................................................................................................ 6
5.2 Test set-up and test procedure ................................................................................... 6
5.3 Measurement uncertainty ........................................................................................... 7
5.4 Test equipment ........................................................................................................... 7
5.5 Test protocol ............................................................................................................... 8
5.2 Test set-up and test procedure ................................................................................... 6
5.3 Measurement uncertainty ........................................................................................... 7
5.4 Test equipment ........................................................................................................... 7
5.5 Test protocol ............................................................................................................... 8
6. Continuous disturbance power ............................................................................................. 9
6.1 Operating environment................................................................................................ 9
6.2 Test set-up and test procedure ................................................................................... 9
6.3 Measurement uncertainty ........................................................................................... 9
6.4 Test equipment ........................................................................................................... 9
6.5 Test protocol ............................................................................................................. 10
6.2 Test set-up and test procedure ................................................................................... 9
6.3 Measurement uncertainty ........................................................................................... 9
6.4 Test equipment ........................................................................................................... 9
6.5 Test protocol ............................................................................................................. 10
7. Harmonics, EN 61 000-3-2................................................................................................. 11
7.1 Operating environment.............................................................................................. 11
7.2 Classification of the EUT........................................................................................... 11
7.3 Test set-up and test procedure ................................................................................. 11
7.4 Measurement uncertainty ......................................................................................... 11
7.5 Test equipment ......................................................................................................... 11
7.6 Test protocol ............................................................................................................. 12
7.2 Classification of the EUT........................................................................................... 11
7.3 Test set-up and test procedure ................................................................................. 11
7.4 Measurement uncertainty ......................................................................................... 11
7.5 Test equipment ......................................................................................................... 11
7.6 Test protocol ............................................................................................................. 12
8. Voltage fluctuations - flicker, EN 61 000-3-3 ...................................................................... 13
8.1 Operating environment.............................................................................................. 13
8.2 Test set-up and test procedure ................................................................................. 13
8.3 Measurement uncertainty ......................................................................................... 13
8.4 Test equipment ......................................................................................................... 13
8.5 Test protocol ............................................................................................................. 13
8.2 Test set-up and test procedure ................................................................................. 13
8.3 Measurement uncertainty ......................................................................................... 13
8.4 Test equipment ......................................................................................................... 13
8.5 Test protocol ............................................................................................................. 13
Test report no. 1018989E
Page 3 (13)
1.
CLIENT INFORMATION
The EUT has been tested by request of:
Company:
Meiloon Industrial Co., Ltd.
No.77, Lane 17745, Chuen-Ryh Road
Taoyuan City
TAIWAN
No.77, Lane 17745, Chuen-Ryh Road
Taoyuan City
TAIWAN
Name of contact:
Ellen Lin
Telephone:
+886-3-326 1611 ext 6204
Telefax:
+886-3-326 3884
2.
EQUIPMENT UNDER TEST (EUT)
2.1 Identification of the EUT
Equipment:
Subwoofer
Type/model:
HKTS210SUB/230
Brand name:
harman/kardon
Serial number:
4#
Manufacturer:
Meiloon Industrial Co., Ltd.
Country of origin:
Taiwan
Rating:
220-240 V AC, 50/60 Hz, 270 W
Class II
Class II
2.2 Additional information about the EUT
The EUT consists of the following units:
Unit
Type
Subwoofer
HKTS210SUB/230
Test report no. 1018989E
Page 4 (13)
3.
TEST SPECIFICATIONS
3.1 Standards
EN 55 013 (2001), Amendment A1 (2003) and Amendment A2 (2006): Sound and television
broadcast receivers and associated equipment – Radio disturbance characteristics - Limits and
methods of measurement.
broadcast receivers and associated equipment – Radio disturbance characteristics - Limits and
methods of measurement.
EN 61 000-3-2 (2006): Limits for harmonic current emissions (equipment input current
16 A).
EN 61 000-3-3 (2008): Limitation of voltage fluctuations and flicker in low-voltage supply systems
for equipment with rated current
for equipment with rated current
16A.
3.2 Additions, deviations and exclusions from standards and accreditation
No additions, deviations or exclusions have been made from standard.
All tests performed are within the scope of the accreditation.
All tests performed are within the scope of the accreditation.
3.3 Mode of operation during the test
During the test the EUT was operating in the following mode:
A 42 Hz sinus signal was connected to “LINE LEVEL IN R/L”
The amplifier was connected to a resistive load and the output level was set to 1/8 of the nominal
maximum audio output power.