Harman Kardon HKTS 210SUB EMC - CB Certificate ▷ View online
Page 21 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
20
Resistance to fire
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
CN1: Base and holder are < 4 g
N/A
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
(see appended table 14)
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1 Potential
ignition
sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
1 mm in width and with openings for wires
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 22 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 23 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4
Table 3 , unless comply with 6.2.2.1.or 6.2.2.2 of
IEC 60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel
ball impact test
ball impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 24 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by
position of the functional switch (W) ………...……..: Standby 0.73W
—
Cond.
Un (V)
Hz
In (mA) Pn (W) Uout (V) Pout (W) Operating Condition / Status
1
198
50
472
44
10.8
29.2
1/8 of maximum output power with
2 264 50 404 45 10.8 29.2
pink noise
3 240 50 423 43 10.8 29.2
4 220 50 442 43 10.8 29.2
5 198 60 479 42 10.8 29.2
6 264 60 405 44 10.8 29.2
7 240 60 427 43 10.8 29.2
8 220 60 449 43 10.8 29.2
Loudspeaker impedance (Ω) ......................…..…..:
4
—
Several loudspeaker systems
-
—
Marking of loudspeaker terminals
-
—
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 2
No ___
No ___
Transformer T2 winding
46
75 (85)
Transformer DT1 winding
29
75 (85)
Transformer T1 winding
46
75 (85)
CT1 winding
29
75 (85)
PWB near C1
27
85
PWB near Heatsink (HS2)
24
85
PWB near Heatsink (HS1)
30
85
PWB near CX2
22
85
ON/OFF button (plastic)
9
50
Metallic enclosure near Phase knob
9
40
Upper backside (wood)
5
60
Topside (wood)
4
60
Winding temperature rise measurements
Ambient temperature t1 (
Ambient temperature t1 (
o
C) ...........................
26
—
Ambient temperature t2 (
o
C) ...........................
26
—
Temperature rise dT of winding:
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit
maxK)
Insulation class
-
- - - -
-
When using thermal elements the normal temperature limit is reduced with 10K