Page 21 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts 
 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined in 
20.1  
CN1: Base and holder are < 4 g 
  
N/A 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4  
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
 N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC60707, unless used in a fire enclosure  
 P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
 N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
(see appended table 14) 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 Potential 
ignition 
sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 N/A 
 
Page 22 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 Marking 
and 
instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1  
 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard  
 N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
Page 23 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in 
Table  3 , unless comply with 6.2.2.1.or 6.2.2.2 of 
IEC 60086-4  
 N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
 N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel 
ball impact test  
 N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 N/A 
Page 24 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF/Stand-by 
 
 
 
position of the functional switch (W) ………...……..:  Standby 0.73W 
— 
Cond. 
Un (V) 
Hz 
In (mA)  Pn (W)  Uout (V)  Pout (W) Operating Condition / Status 
198 
50 
472 
44 
10.8 
29.2 
 1/8 of maximum output power with  
2 264 50 404 45 10.8 29.2 
pink noise 
3 240 50 423 43 10.8 29.2 
 
4 220 50 442 43 10.8 29.2 
  
5 198 60 479 42 10.8 29.2 
 
6 264 60 405 44 10.8 29.2 
 
7 240 60 427 43 10.8 29.2 
 
8 220 60 449 43 10.8 29.2 
 
 
Loudspeaker impedance (Ω) ......................…..…..: 
— 
 
Several loudspeaker systems 
— 
 
Marking of loudspeaker terminals 
— 
Temperature Rise dT of Part 
dT (K) 
Limit max dT (K) 
Test Condition No. 
No 2 
No ___ 
No ___ 
 
Transformer T2 winding  
46 
 
 
75 (85) 
Transformer DT1 winding  
29 
 
 
75 (85) 
Transformer T1 winding  
46 
 
 
75 (85) 
CT1 winding  
29 
 
 
75 (85) 
PWB near C1  
27 
 
 
85 
PWB near Heatsink (HS2) 
24 
 
 
85 
PWB near Heatsink (HS1) 
30 
 
 
85 
PWB near CX2  
22 
 
 
85 
ON/OFF button (plastic) 
 
 
50 
Metallic enclosure near Phase knob 
 
 
40 
Upper backside (wood) 
 
 
60 
Topside (wood) 
 
 
60 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ...........................
26 
 
 
 
— 
Ambient temperature t2 (
o
C) ...........................
26 
 
 
 
— 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) – (t2 – t1) 
             R
1
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit 
maxK) 
Insulation class 
- - - - 
When using thermal elements the normal temperature limit is reduced with 10K  
Page of 56