Harman Kardon HKTS 210SUB EMC - CB Certificate ▷ View online
Page 9 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
N/A
b) Touch current measured from terminal devices
using the network in annex D .................................:
using the network in annex D .................................:
Voltage U1 = 0.97V Peak
Voltage U2 = 0.24V Peak
Voltage U2 = 0.24V Peak
P
c) Discharge not exceeding 45 μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
N/A
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
P
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
P
b) Test hook of fig. 4 for 10 s (20 N)
N/A
c) 30 mm diameter test tool for 5 s (100 or 250 N)
250 N
P
9.2
No hazard after removing a cover by hand
N/A
Page 10 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ...........................: 48
h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
N/A
No hazard from softening solder
P
Soldered terminations not used as protective mechanism
N/A
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
(see appended table 11.2)
P
Page 11 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg
8.5kg
P
12.1.2
Vibration test
No connection or part that might
impair safety can become
loose.
impair safety can become
loose.
N/A
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
See table 13
P
13.3
Clearances
P
13.3.1 General
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9 :
comply with table 8 and, where applicable, table 9 :
See table 13
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4 Measurement
of
transient voltages
N/A
13.4
Creepage distances
P
Creepage distances greater than table 11 minimum
values
values
P
Page 12 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.5
Printed boards
P
13.5.1
Clearances and creepage distances between conductors
on printed circuit boards, one of which may be
conductively connected to the mains, as in fig. 10
on printed circuit boards, one of which may be
conductively connected to the mains, as in fig. 10
P
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains,
clearances and creepage distances as in table 12
not conductively connected to the mains,
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors
separately approved ...............................:
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ...: Y1: CY1, CY2, CY3, CY4
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ...: X2: CX1, CX2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ......................:
connected to the mains: tests for X2 ......................:
-
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ........................... :
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ........................... :
CX1 P
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................:
metal ........................................................................:
No N/A