Page 5 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
3 General 
requirements 
 
 
Safety class of the apparatus ..................................  Class II 
 
4 General 
test 
conditions 
 
4.1.4 
Ventilation instructions require the use of the test 
box  
No N/A 
 
5 Marking 
and 
instructions 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit  
In serial production will marking-
plate be screen print  
5.1 a) 
Identification, 
maker .............................................: harman/kardon P 
 
b) Model number or type reference..........................: HKTS210SUB/230 P 
 
c) Class II symbol if applicable ................................:
 
 d) 
Nature 
of supply....................................................:
  
 
e) Rated supply voltage ...........................................: 220-240V  
 
f) Mains frequency if safety dependant ...................: 50/60Hz 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use ............................................................................:
 N/A 
 
Measured current or power consumption  ...............:  
N/A 
 
Deviation %  (max 10%)  ..........................................: - 
 
h) Power consumption marking for apparatus other 
than single phase  .....................................................:
 N/A 
 
i) Rated current or power consumption for 
apparatus intended for connection to an a.c. mains 
supply .......................................................................:
270W P 
 
Measured current or power consumption  ...............: 45W P 
 
Deviation %  (max 10%)  ..........................................:  
N/A 
5.2 
Earth terminal  
 
N/A 
 
Hazardous live terminals  
 
N/A 
 
Supply output terminals (other than mains)  
 
N/A 
5.3 
Use of triangle with exclamation mark  
 
Page 6 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
5.4 
Instructions for use  
 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
 P 
 
b) Hazardous live terminals, instructions for wiring     
N/A 
 
c) Instructions for replacing lithium battery  
 
N/A 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 P 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Mains plug  
 
c) Instructions for permanently connected 
equipment  
 N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 P 
 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  .....:  
N/A 
 
Emission limits under fault conditions  .....................:  
N/A 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
N/A 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
 N/A 
Page 7 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Constructional requirements with regard to the protection against electric 
shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
 N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
 P 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 P 
8.5 
Class I equipment  
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment  
 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Transformer T1, T2, DT1, CT1 
 
Components bridging double or reinforced 
insulation complying with 14.1 a) or 14.3  
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
CY1, CY2, CY3, CY4 
8.7 
This clause is void  
 
 
Page 8 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) 
.............................................................................. ...: 
 
Primary wire supplementary  
 
Reinforced insulation > 0,4 mm (mm)  ....................:  Bobbin: CT1  
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
 P 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3  
Transformer DT1 
 
Reinforced insulation, three layers any two which 
meet 10.3  
Transformer, T2 (Tape) 
Transformer T1 (TIW) 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts  
 P 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts  
 P 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
 P 
 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts.
 P 
8.11 
Detaching of wires  
 
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No risk of any wire becoming 
detached 
N/A 
 
Vibration test carried out  .........................................: No, 
no need, see above  
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s)  
 N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N 
for 10 s)  
 P 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
 P 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
 N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
Page of 56