Harman Kardon HKTS 210SUB EMC - CB Certificate ▷ View online
Page 5 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
3 General
requirements
Safety class of the apparatus .................................. Class II
P
4 General
test
conditions
4.1.4
Ventilation instructions require the use of the test
box
box
No N/A
5 Marking
and
instructions
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
In serial production will marking-
plate be screen print
plate be screen print
P
5.1 a)
Identification,
maker .............................................: harman/kardon P
b) Model number or type reference..........................: HKTS210SUB/230 P
c) Class II symbol if applicable ................................:
P
d)
Nature
of supply....................................................:
P
e) Rated supply voltage ...........................................: 220-240V
P
f) Mains frequency if safety dependant ...................: 50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................:
apparatus supplied by supply apparatus for general
use ............................................................................:
N/A
Measured current or power consumption ...............:
N/A
Deviation % (max 10%) ..........................................: -
P
h) Power consumption marking for apparatus other
than single phase .....................................................:
than single phase .....................................................:
N/A
i) Rated current or power consumption for
apparatus intended for connection to an a.c. mains
supply .......................................................................:
apparatus intended for connection to an a.c. mains
supply .......................................................................:
270W P
Measured current or power consumption ...............: 45W P
Deviation % (max 10%) ..........................................:
N/A
5.2
Earth terminal
N/A
Hazardous live terminals
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
P
Page 6 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.4
Instructions for use
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
P
b) Hazardous live terminals, instructions for wiring
N/A
c) Instructions for replacing lithium battery
N/A
d) Class I earth connection warning
N/A
e) Instructions for multimedia system connection
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
P
g) Warning: battery exposure to heat
N/A
h) Warning: protective film on CRT face
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Mains plug
P
c) Instructions for permanently connected
equipment
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
P
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .....:
N/A
Emission limits under fault conditions .....................:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
N/A
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
N/A
Page 7 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8
Constructional requirements with regard to the protection against electric
shock
shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
P
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Transformer T1, T2, DT1, CT1
P
Components bridging double or reinforced
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
N/A
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY1, CY2, CY3, CY4
P
8.7
This clause is void
—
Page 8 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.8
Basic or supplementary insulation > 0,4 mm (mm)
.............................................................................. ...:
Primary wire supplementary
P
Reinforced insulation > 0,4 mm (mm) ....................: Bobbin: CT1
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
Transformer DT1
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Transformer, T2 (Tape)
Transformer T1 (TIW)
Transformer T1 (TIW)
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N/A
Vibration test carried out .........................................: No,
no need, see above
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N
for 10 s)
for 10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A