Harman Kardon HKTS 210SUB EMC - CB Certificate ▷ View online
Page 25 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal con-
ditions (
o
C)
T - fault condi-
tions (
o
C)
Min T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>10
Min 2
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
>10
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120
No
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
4240
No
Page 26 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. 220-240
—
Frequency
(Hz)........................................................ 50/60
—
Ambient
temperature
(
o
C) ...................................... 26 – 27
—
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
1
Apparatus
Maximum no
clip output
power
clip output
power
Transf. T2 = 67K
Transf. T1 = 51K
Heatsink HS2 = 50K
Other temperature
no higher
Transf. T1 = 51K
Heatsink HS2 = 50K
Other temperature
no higher
U
n
= 264V, P
n
= 60W, I
n
= 0.58A U
out
= 18V
After 3.5 hours
U
U
n
= 264V, P
n
= 58W, I
n
= 0.57A U
out
= 18V
2
C6
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.42A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 47mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
3
C6
Short circuit No heat
development
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 198V, P
n
= 0.6W, I
n
= 36mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
4
C26
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.36A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 48mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 37mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Page 27 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
5
C3
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.36A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 47mA U
out
= 0V
U
n
= 198V, P
n
= 0.5W, I
n
= 35mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
6
U2
Short circuit
On the
secondary
side.
On the
secondary
side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.44A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 48mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 38mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
7 U2
Short
circuit
On the
primary side.
primary side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.4W, I
n
= 45mA U
out
= 0V
U
n
= 198V, P
n
= 0.3W, I
n
= 34mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
8 U2
Disconnect
device on
primary side.
device on
primary side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.43A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 49mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 38mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Page 28 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
9
C22
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 2.8W, I
n
= 53mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 52mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
10
R38
Short circuit T2 = 16K
DT1 = 30K
U1 = 65K
CT1 = 36K
Other temperature
no higher
U1 = 65K
CT1 = 36K
Other temperature
no higher
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 7.3W, I
n
= 76mA U
out
= 0V
The test went on for 2 hours.
11
R38
Short circuit T2 = 16K
DT1 = 24K
U1 = 66K
CT1 = 37K
Other temperature
no higher
U1 = 66K
CT1 = 37K
Other temperature
no higher
U
n
= 198V, P
n
= 44W, I
n
= 0.46A U
out
= 10.8V
Immediately after fault condition
U
n
= 198V, P
n
= 6.8W, I
n
= 83mA U
out
= 0V
The test went on for 2 hours and 10 minutes.
12 BR1
Short
circuit
-
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.41A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 0V, P
n
= 0W, I
n
= 0A U
out
= 0V
U
n
= 0V, P
n
= 0W, I
n
= 0A U
out
= 0V
Fuse activated immediately
13
C1 near U1
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
The test went on for 5 more minutes.
No remarks
Click on the first or last page to see other HKTS 210SUB service manuals if exist.