Page 13 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table 11.2)
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass > 7 kg
Approx. 8.6 kg, the EUT is still
complying with relevant
requirements of this standard
complying with relevant
requirements of this standard
P
12.1.2
Vibration test
The EUT is still complying with
relevant requirements of this
standard
relevant requirements of this
standard
P
12.1.3
Impact hammer test
The EUT is still complying with
relevant requirements of this
standard
relevant requirements of this
standard
P
Steel ball test
The EUT is still complying with
relevant requirements of this
standard
relevant requirements of this
standard
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Approx. 8.6 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
70
°
C / 7 hours, all the
enclosure materials listed in
the table 14 are tested. After
the test, no dangerous moving
parts or hazardous live parts
are accessible
the table 14 are tested. After
the test, no dangerous moving
parts or hazardous live parts
are accessible
P
12.2
Fixing of knobs, push buttons, keys and levers
The EUT is still complying with
relevant requirements of this
standard
relevant requirements of this
standard
P
12.3
Remote controls with hazardous live parts
No remote control device with
hazardous live parts
hazardous live parts
P
12.4
Drawers (pull test 50 N, 10 s)
The EUT is still complying with
relevant requirements of this
standard
relevant requirements of this
standard
P
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided
provided
N/A
12.6
Telescoping or rod antennas construction
No such device
N/A
12.6.1
Telescoping or rod antennas securement
N/A
Page 14 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
13
CLEARANCES AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
13.3
Clearances
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Approved building-in power
supply module is provided (see
also appended tables 13.3
and 13.4)
supply module is provided (see
also appended tables 13.3
and 13.4)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minima
Approved building-in power
supply module is provided (see
also appended tables 13.3
and 13.4)
supply module is provided (see
also appended tables 13.3
and 13.4)
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength
test
test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No such part
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Page 15 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
14
COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistor within the
approved building-in power
supply module
approved building-in power
supply module
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
No such resistor within the
approved building-in power
supply module
approved building-in power
supply module
N/A
Resistors separately approved .............................. :
N/A
14.2
Capacitors and RC units
Capacitors separately approved
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Evaluated in approved
building-in power supply
module
module
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : Evaluated in approved
building-in power supply
module;
module;
X-Capacitor bridged between
Line and Neutral of power
switch: Class X2
Line and Neutral of power
switch: Class X2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC 60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC 60384-1, 4.38 category B or
better ....................................................................... :
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ........................................ :
N/A
Shielded by a barrier acc. to 20.1.4/table 21 or
metal ....................................................................... :
metal ....................................................................... :
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Page 16 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Transformers and inductors separately approved :
N/A
14.3.2
General
See sub-clauses 14.3.3,
14.3.4.1 and 14.3.5.1
14.3.4.1 and 14.3.5.1
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Coil formers and partition walls > 0,4 mm
N/A
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Coil formers and partition walls > 0,4 mm
N/A
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high-voltage component
within the EUT
within the EUT
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices