ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
Approved appliance inlet is 
provided 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
 
N/A 
15.4 
Devices forming a part of the mains plug 
 
15.4.1 
No undue strain on mains socket-outlets 
The EUT is not direct plug-in 
apparatus 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests a, 
b, c) 
 
N/A 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................ : 
See the Note in appended 
table 14 
N/A 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Approved appliance inlet is 
provided  
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
 
N/A 
 
 
 
 
Page 22 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
N/A 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 
N/A 
16.5 
Adequate strain relief on external flexible cords 
Approved appliance inlet is 
provided  
N/A 
 
Not possible to push cord back into equipment 
 
N/A 
 
Strain relief device unlikely to damage flexible cord   
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 
N/A 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
 
 
- screws into metal: 5 times 
Enclosure: 0.4 Nm (screw 
diameter: 2.8 mm) 
 
- screws into non-metallic material: 10 times 
 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material 
 
17.3 
Cover fixing screws: captive 
 
N/A 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 
 
 
 
 
Page 23 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
 
N/A 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
 
N/A 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No such device 
N/A 
17.8 
Fixing devices for detachable legs or stands 
provided 
No such device 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
All connectors are reliably 
secured 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
 
Picture tube separately approved to IEC 61965….:  No picture tube 
N/A 
 
Picture tube separately approved to 18.1............... :   
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
N/A 
 
Non-intrinsically protected tubes > 16 cm used 
with protective screen 
 
N/A 
 
Protective film as part of implosion protection: 
edges covered by enclosure 
 
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
N/A 
18.2.1 
Samples subject to ageing: 6 
 
N/A 
18.2.2 
Samples subject to implosion test: 6 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
N/A 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 7 kg ................. :  Approx. 8.6 kg  
 
Apparatus intended to be fastened in place – 
suitable instructions 
 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
 
 
 
 
Page 24 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
100 N force, or 13 % of weight, applied horizontally 
to point of least stability 
 
N/A 
19.4 
Edges or corners not hazardous 
The outer surface of the EUT 
is smoothed. No sharp edges 
and corners 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
 
N/A 
19.6 
Wall or ceiling mountings adequate 
 
N/A 
 
20 
RESISTANCE TO FIRE 
 
20.1 
Electrical components and mechanical parts 
 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
Metal enclosure, others 
complied with sub-clause 
20.1.1 
 20.1.4 
N/A 
 
b) Exemption for small components as defined in 
20.1 
Components are mounted on 
PCB of min. V-0 (for power 
supply module) and min. V-1 
(for others) 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
Electrical components 
complied with flammability 
requirements in clause 14; 
Evaluated in approved 
building-in power supply 
module; 
The plastic front panel and 
two plastic side covers 
complied with sub-clause 
20.1.4 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
No voltages more than 4 kV 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC 60707, unless used in a fire 
enclosure 
The PCB (for others) has the 
flammability rating of min. V-1   
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage > 
400 V (peak) a.c. or d.c. meets V-0 to IEC 60707 
The PCB (for power supply 
module) has the flammability 
rating of min. V-0 