Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate ▷ View online
Page 21 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
Approved appliance inlet is
provided
provided
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
The EUT is not direct plug-in
apparatus
apparatus
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests a,
b, c)
b, c)
N/A
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
See the Note in appended
table 14
table 14
N/A
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Approved appliance inlet is
provided
provided
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
N/A
Page 22 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
Approved appliance inlet is
provided
provided
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
- screws into metal: 5 times
Enclosure: 0.4 Nm (screw
diameter: 2.8 mm)
diameter: 2.8 mm)
P
- screws into non-metallic material: 10 times
N/A
17.2
Correct introduction into female threads in non-
metallic material
metallic material
P
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
P
Page 23 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No such device
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
No such device
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
All connectors are reliably
secured
secured
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965….: No picture tube
N/A
Picture tube separately approved to 18.1............... :
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used
with protective screen
with protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. : Approx. 8.6 kg
P
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
Page 24 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
19.2
100 N force applied vertically downwards
P
19.3
100 N force, or 13 % of weight, applied horizontally
to point of least stability
to point of least stability
N/A
19.4
Edges or corners not hazardous
The outer surface of the EUT
is smoothed. No sharp edges
and corners
is smoothed. No sharp edges
and corners
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
Metal enclosure, others
complied with sub-clause
20.1.1
complied with sub-clause
20.1.1
∼
20.1.4
N/A
b) Exemption for small components as defined in
20.1
20.1
Components are mounted on
PCB of min. V-0 (for power
supply module) and min. V-1
(for others)
PCB of min. V-0 (for power
supply module) and min. V-1
(for others)
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
Electrical components
complied with flammability
requirements in clause 14;
complied with flammability
requirements in clause 14;
Evaluated in approved
building-in power supply
module;
building-in power supply
module;
The plastic front panel and
two plastic side covers
complied with sub-clause
20.1.4
two plastic side covers
complied with sub-clause
20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
No voltages more than 4 kV
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60707, unless used in a fire
enclosure
The PCB (for others) has the
flammability rating of min. V-1
flammability rating of min. V-1
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets V-0 to IEC 60707
The PCB (for power supply
module) has the flammability
rating of min. V-0
module) has the flammability
rating of min. V-0
P