ST-07348  
 
TRF No.: IECEN60065G 
 
 
 
Test item particulars 
 
Classification of installation and use ......................... :  Class I 
Supply connection  .................................................... :  An appliance inlet for connection of a detachable 
power supply cord 
Possible test case verdicts 
 
Test case does not apply to the test object  ................ :  N/A (Not Applicable) 
Test item does meet the requirement  ......................... :  P (Pass) 
Test item does not meet the requirement  ................... :  F (Fail) 
Testing 
 
Date of receipt of test item ........................................... :  October 7, 2007 
Date(s) of performance of test ..................................... :  October 8, 2007 
 December 5, 2007 
General remarks 
The test results presented in this report relate only to the object(s) tested. 
This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. 
“(see Appendix #)” refers to additional information appended to the report. 
“(see appended table #)” refers to a table appended to the report. 
 
Throughout this report, a point (comma) is used as the decimal separator. 
List of test equipment must be kept on file and available for review. 
Additional information 
Additional special deviations of CN (China), IN (India), JP (Japan), KR (Republic of Korea), SG 
(Singapore), TR (Turkey), UA (Ukraine) and ZA (South Africa) of IEC 60065, 6th ed. are checked. 
Additional special deviations of CN (China) and SG (Singapore) of IEC 60065, 5th ed. + Amds 1, 2 and 3 
are checked. 
 
 
 
 
Page 6 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
GENERAL REQUIREMENTS 
 
 
Safety class of the apparatus ................................. :  The EUT is Class I apparatus 
 
GENERAL TEST CONDITIONS  
 
4.1.4 
Ventilation instructions require the use of the test 
box 
According to the 
manufacturer’s instruction 
N/A 
 
MARKING AND INSTRUCTIONS 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit 
After rubbing test by water and 
petroleum spirit, the marking 
still legible; it is not easily 
possible to remove the 
marking plate and show no 
curling 
5.1 
Identification, maker, model  ................................... : 
;              
DMC1000 
 
Class II symbol if applicable 
The EUT is Class I apparatus 
N/A 
 
Rated supply voltage and symbol .......................... :  100-240 V
 
 
Frequency if safety dependant 
50/60 Hz 
 
Rated current or power consumption  .................... :  135 W 
5.2 
Earth terminal 
Appliance inlet is used 
N/A 
 
Hazardous live terminals 
No hazardous live terminal 
N/A 
 
Supply output terminals (other than mains) 
No such terminals 
N/A 
5.3 
Use of triangle with exclamation mark 
 
5.4 
Instructions for use 
 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
The instruction “Do not expose 
this apparatus to dripping or 
splashing and ensure that no 
objects filled with liquids, such 
as vases, are placed on the 
apparatus.” provided (see also 
Appendix 2) 
 
Hazardous live terminals, instructions for wiring 
No hazardous live terminal 
N/A 
 
Instructions for replacing lithium battery 
Only one 3 Vdc RTC battery 
within the EUT 
 
Instructions for modem if fitted 
No such device within the EUT 
N/A 
 
 
 
 
Page 7 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
Class I earth connection warning 
 
 
Instructions for multimedia system connection 
No such connection 
N/A 
 
Special stability warning for fixed installation 
No such construction 
N/A 
 
Warning: battery exposure to heat 
Two “AA” heavy duty or 
alkaline type batteries 
provided for the remote 
controller, and a RTC battery 
is provided within the EUT.  
The instruction “Do not 
expose batteries to excessive 
heat such as sunshine, fire or 
the like.” provided (see also 
Appendix 2) 
 
Warning: protective film on CRT face 
No such device within the EUT 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
The instruction “To completely 
disconnect this apparatus 
from the AC Mains, 
disconnect the power supply 
cord plug from the AC 
receptacle.” and “The mains 
plug of the power supply cord 
shall remain readily operable.” 
provided (see also Appendix 2) 
 
Instructions for permanently connected equipment  The EUT is not such apparatus 
N/A 
 
HAZARDOUS RADIATIONS 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
The EUT does not generate 
ionizing radiation 
N/A 
6.1         
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10 cm from outer surface of apparatus 
< 1 µSv/h (0,1 mR/h) 
The EUT does not generate 
ionizing radiation 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 .... :  The LEDs are considered to 
be complied with the 
requirement of Class 1 LED 
product; 
The optical drive complies 
with IEC/EN 60825-1; 
The fiber optic transmitting 
module is tested according to 
IEC/EN 60825-1 and see also 
Appendix 1 
 
Emission limits under fault conditions .................... :  See above 
 
 
 
 
Page 8 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts 
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table 7.1) 
7.1.4 
Temperature rise of windings 
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
Evaluated in approved 
building-in power supply 
module and see also 
appended table 7.2 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Windings are covered by 
lacquer 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No such components are 
replaced by hand 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
The EUT is complied with the 
requirements 
8.5 
Class I equipment 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Also evaluated in approved 
building-in power supply 
module 
 
A resistor bridging basic insulation complying with 
14.1 a) 
No such resistor 
N/A 
 
A capacitor bridging basic insulation complying 
with 14.2.1 a) 
Evaluated in approved 
building-in power supply 
module 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Evaluated in approved 
building-in power supply 
module 