Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate ▷ View online
Page 5 of 100
ST-07348
TRF No.: IECEN60065G
Test item particulars
Classification of installation and use ......................... : Class I
Supply connection .................................................... : An appliance inlet for connection of a detachable
power supply cord
Possible test case verdicts
Test case does not apply to the test object ................ : N/A (Not Applicable)
Test item does meet the requirement ......................... : P (Pass)
Test item does not meet the requirement ................... : F (Fail)
Testing
Date of receipt of test item ........................................... : October 7, 2007
Date(s) of performance of test ..................................... : October 8, 2007
∼
December 5, 2007
General remarks
The test results presented in this report relate only to the object(s) tested.
This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory.
This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory.
“(see Appendix #)” refers to additional information appended to the report.
“(see appended table #)” refers to a table appended to the report.
“(see appended table #)” refers to a table appended to the report.
Throughout this report, a point (comma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
Additional information
Additional special deviations of CN (China), IN (India), JP (Japan), KR (Republic of Korea), SG
(Singapore), TR (Turkey), UA (Ukraine) and ZA (South Africa) of IEC 60065, 6th ed. are checked.
(Singapore), TR (Turkey), UA (Ukraine) and ZA (South Africa) of IEC 60065, 6th ed. are checked.
Additional special deviations of CN (China) and SG (Singapore) of IEC 60065, 5th ed. + Amds 1, 2 and 3
are checked.
are checked.
Page 6 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
3
GENERAL REQUIREMENTS
Safety class of the apparatus ................................. : The EUT is Class I apparatus
P
4
GENERAL TEST CONDITIONS
4.1.4
Ventilation instructions require the use of the test
box
box
According to the
manufacturer’s instruction
manufacturer’s instruction
N/A
5
MARKING AND INSTRUCTIONS
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
After rubbing test by water and
petroleum spirit, the marking
still legible; it is not easily
possible to remove the
marking plate and show no
curling
petroleum spirit, the marking
still legible; it is not easily
possible to remove the
marking plate and show no
curling
P
5.1
Identification, maker, model ................................... :
;
DMC1000
P
Class II symbol if applicable
The EUT is Class I apparatus
N/A
Rated supply voltage and symbol .......................... : 100-240 V
P
Frequency if safety dependant
50/60 Hz
P
Rated current or power consumption .................... : 135 W
P
5.2
Earth terminal
Appliance inlet is used
N/A
Hazardous live terminals
No hazardous live terminal
N/A
Supply output terminals (other than mains)
No such terminals
N/A
5.3
Use of triangle with exclamation mark
P
5.4
Instructions for use
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
The instruction “Do not expose
this apparatus to dripping or
splashing and ensure that no
objects filled with liquids, such
as vases, are placed on the
apparatus.” provided (see also
Appendix 2)
this apparatus to dripping or
splashing and ensure that no
objects filled with liquids, such
as vases, are placed on the
apparatus.” provided (see also
Appendix 2)
P
Hazardous live terminals, instructions for wiring
No hazardous live terminal
N/A
Instructions for replacing lithium battery
Only one 3 Vdc RTC battery
within the EUT
within the EUT
P
Instructions for modem if fitted
No such device within the EUT
N/A
Page 7 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Class I earth connection warning
P
Instructions for multimedia system connection
No such connection
N/A
Special stability warning for fixed installation
No such construction
N/A
Warning: battery exposure to heat
Two “AA” heavy duty or
alkaline type batteries
provided for the remote
controller, and a RTC battery
is provided within the EUT.
The instruction “Do not
expose batteries to excessive
heat such as sunshine, fire or
the like.” provided (see also
Appendix 2)
alkaline type batteries
provided for the remote
controller, and a RTC battery
is provided within the EUT.
The instruction “Do not
expose batteries to excessive
heat such as sunshine, fire or
the like.” provided (see also
Appendix 2)
P
Warning: protective film on CRT face
No such device within the EUT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
The instruction “To completely
disconnect this apparatus
from the AC Mains,
disconnect the power supply
cord plug from the AC
receptacle.” and “The mains
plug of the power supply cord
shall remain readily operable.”
provided (see also Appendix 2)
disconnect this apparatus
from the AC Mains,
disconnect the power supply
cord plug from the AC
receptacle.” and “The mains
plug of the power supply cord
shall remain readily operable.”
provided (see also Appendix 2)
P
Instructions for permanently connected equipment The EUT is not such apparatus
N/A
6
HAZARDOUS RADIATIONS
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
The EUT does not generate
ionizing radiation
ionizing radiation
N/A
6.1
EN 60065
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10 cm from outer surface of apparatus
< 1 µSv/h (0,1 mR/h)
May 1996 10 cm from outer surface of apparatus
< 1 µSv/h (0,1 mR/h)
The EUT does not generate
ionizing radiation
ionizing radiation
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : The LEDs are considered to
be complied with the
requirement of Class 1 LED
product;
requirement of Class 1 LED
product;
The optical drive complies
with IEC/EN 60825-1;
with IEC/EN 60825-1;
The fiber optic transmitting
module is tested according to
IEC/EN 60825-1 and see also
Appendix 1
module is tested according to
IEC/EN 60825-1 and see also
Appendix 1
P
Emission limits under fault conditions .................... : See above
P
Page 8 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Evaluated in approved
building-in power supply
module and see also
appended table 7.2
building-in power supply
module and see also
appended table 7.2
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings are covered by
lacquer
lacquer
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No such components are
replaced by hand
replaced by hand
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
The EUT is complied with the
requirements
requirements
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Also evaluated in approved
building-in power supply
module
building-in power supply
module
P
A resistor bridging basic insulation complying with
14.1 a)
14.1 a)
No such resistor
N/A
A capacitor bridging basic insulation complying
with 14.2.1 a)
with 14.2.1 a)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Click on the first or last page to see other DMC 1000 (serv.man2) service manuals if exist.