IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
14.5.1.1
a) Thermal cut-outs separately approved
No such device within the EUT
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such device within the EUT
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such device within the EUT
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
The fuse-link is approved
according to IEC 60127
according to IEC 60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Evaluated in approved
building-in power supply
module
module
P
14.5.2.3
Not possible to connect fuses in parallel ............... : No fuse holder is designed to
be connected in parallel in the
same circuit
same circuit
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
The fuse-link is soldered to the
approved building-in power
supply module inside of
apparatus
approved building-in power
supply module inside of
apparatus
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such device within the EUT
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
No such device within the EUT
N/A
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
Approved power switch is
provided
provided
N/A
14.6.1 b)
Tested in the apparatus:
Switch controlling > 0.2 A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Page 18 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Switch controlling > 0.2 A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2 A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
No such device within the EUT
N/A
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
accidentally
No such device within the EUT
N/A
14.9
Motors
14.9.1
Endurance test on motors
The motors of optical drive and
two low voltage DC fans are
provided
two low voltage DC fans are
provided
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
Two “AA” heavy duty or
alkaline type batteries
provided for the remote
controller and a RTC battery is
provided within the EUT
alkaline type batteries
provided for the remote
controller and a RTC battery is
provided within the EUT
P
Page 19 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
No battery charging circuit
within the remote controller
within the remote controller
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
No rechargeable battery is
provided
provided
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
The measured values were not
exceeded the limits
exceeded the limits
P
14.10.4
Battery mould stress relief
Not such battery
N/A
14.10.5
Battery drop test
Not such battery
N/A
14.11
Optocouplers
Optocouplers comply with Cl. 8
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
14.12
Surge suppression varistors
Comply with IEC 61051-2
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
P
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
P
15
TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved appliance inlet is
provided
provided
P
Overloading of plugs or appliance inlets
prevented if the apparatus has mains socket
outlets
prevented if the apparatus has mains socket
outlets
No mains socket outlet
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket outlet
N/A
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No such outlet
N/A
Page 20 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
The EUT is not such device
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Green/yellow wire is hooked-
in and soldered to the earth
pin of appliance inlet, and
screwed with ring type crimp
terminal to protective bonding
chassis by a screw with lock-
washer
in and soldered to the earth
pin of appliance inlet, and
screwed with ring type crimp
terminal to protective bonding
chassis by a screw with lock-
washer
P
Protective earth conductors correctly coloured
Coloured green/yellow on
protective bonding wire
protective bonding wire
P
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
Approved appliance inlet is
provided
provided
N/A
Protective earth terminal resistant to corrosion
All protective earthing and
bonding connections are in
compliance with Annex F
bonding connections are in
compliance with Annex F
P
Earth resistance test: < 0,1
Ω
at 25 A ................... : 7 m
Ω
(Resistance from the
earth pin of appliance inlet to
the farthest earthed
accessible parts)
the farthest earthed
accessible parts)
P
15.3
Terminals for external flexible cords and for permanent connection to the
mains supply
mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
The EUT is not a permanently
connected apparatus
connected apparatus
N/A
15.3.2
Reliable connection of non-detachable cords:
Not soldered to conductors of a printed circuit
board
board
Approved appliance inlet is
provided
provided
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N/A
Click on the first or last page to see other DMC 1000 (serv.man2) service manuals if exist.