Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online

  
Page 
7
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
7.1.4 
Temperature rise of windings 
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
Approved components 
according to relevant IEC 
stanards.. 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Considered
 
P
 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Operation “By hand” 
not possible 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic materials used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by hand 
8.5 
Class I equipment 
Class II equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
Class II apparatus. 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
The apparatus have isolating 
transformers. 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such capacitors. 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such capacitors.
 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
No such capacitors.
 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components.
 
TRF No:  IEC/EN 60065F 
  
Page 
8
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
No parts at 35-71V(peak) a.c. 
or 60-120V d.c. 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
No parts at 35-71V(peak) a.c. 
or 60-120V d.c. 
 
Separation by Class II isolating transformer 
Isolating transformer 
according to 14.3.2. (Class II) 
 
Separation by Class I transformer 
 
 
Separation by earthed conductive part 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) :
 
 Reinforced 
insulation > 0,4 mm (mm) .................... :
Transformer bobbin, 
See appended table and 
attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
Thin sheet insulation 
No thin sheet insulation 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Double insulated. 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
Single insulation but safely 
anchored 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
Double insulated, tested 
according to 8.9. and 10.3. 
8.11 
Detaching of wires 
 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
Primary wires connected with 
multi-contact-housing.
 
 Vibration 
test carried out  ........................................ :
See 12,1,2  
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
No internal wiring for socket-
outlets, but protective fuse 
provided (F201, T2A L 250V) 
TRF No:  IEC/EN 60065F 
  
Page 
9
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
Adequately fastened. 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
Covers adequately fastened 
with screws. 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
Wires safely anchored away 
from parts with high 
temperature. 
8.16 
Only special supply equipment can be used 
No special supply apparatus. 
8.17 
Insulated winding wire without additional 
interleaved insulation 
No such components 
8.18 
Endurance test as required by 8.17 
 
8.19 
Disconnection from the mains 
See below 
8.19.1 Disconnect 
device 
The appliance coupler in cord 
set is disconnecting device. 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
No mains all-pole switch or 
circuit breaker 
8.19.2 
Mains switch ON indication 
Indicator lamp or FL display 
lit-on
 
8.20 
Switch not fitted in the mains cord 
No switch not fitted in the 
mains cord 
8.21 
Bridging components comply with clause 14 
C101 capacitor bridging relay 
contact gap is certified 
component 
See appended table, list of 
critical components. 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 1000V 
AC or 1500V DC. 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
See attachment, Table to 
EN/IEC 60065 7
th
 Edition 
 
Discharge not exceeding 45 µC 
No part or contact of a terminal 
with stored voltages between 
60V - 15 kV. 
 
Energy of discharge not exceeding 350 mJ 
No part or contact of a 
terminal with stored voltages 
exceeding 15kV 
9.1.1.2 
Test with test finger and test probe 
No access for the test finger 
TRF No:  IEC/EN 60065F 
  
Page 
10
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No live shaft, handles or levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
No access for the test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
Does not reach hazardous live 
parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
Does not reach hazardous live 
parts 
9.1.5 
Pre-set controls tested with 2 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No preset controls 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
0 V after 2 sec.
 
 
If C is not greater than 0,1 µF no test needed 
 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
Test with test finger results in 
no hazard. 
 
Test hook of fig. 4 for 10 s (20 N) 
Test with test hook results in 
no hazard. 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... :
Test with 100N results in no 
damage. 
9.2 
No hazard after removing a cover by hand 
No cover removable by hand 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
> 100 MΩ 
 
10.2 Humidity 
treatment 48 h or 120 h ........................... :
120 h (40°C). No impairment 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
 
 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
No electric shock hazard under 
fault conditions. 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
No softning of solder 
TRF No:  IEC/EN 60065F 
Page of 46