Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online
- Page 31 of 31 -
www.nemko.com
Report No.
72390
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
No TNV circuits
N
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus.
N
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
N
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N
IT: certification number on the back cover
N
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No switches containing
mercury
mercury
N
TRF No: IEC/EN 60065F
- Page 1 of 8 -
Order
No.
72390
ATTACHMENT: Tables to EN/IEC 60065 7
th
edition
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location Measured
U1V
(peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Mains pole 1 – Antenn terminal
Mains pole 2 – Antenn terminal
Mains pole 2 – Antenn terminal
- -
<0,05Vpeak
Pass
Mains pole 1 – other part or contact
Mains pole 2 – other part or contact
Mains pole 2 – other part or contact
- -
<0,05Vpeak
Pass
Comments:
Only U2 have been recorded due to the use of a linear transformer in power supply.
TRF No: IEC/EN 60065F
- Page 2 of 8 -
Order
No.
72390
11
FAULT CONDITIONS TESTS
P
Voltage(V) 0,9 or 1,1 times rated voltage……….
207V or 253V
—
Ambient temperature(℃)……………………………
23 - 26°C
—
Comp.
No.
No.
Location
Fault Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
D801
AC - “+”
S-c
253
1 sec.
F101
-
F101 opened immediately.
Input current stabilised at 0,06A.
No hazard.
Input current stabilised at 0,06A.
No hazard.
D801
AC - “+”
S-c
207
1 sec.
F101
-
F101 opened immediately.
Input current stabilised at 0,03A.
No hazard.
Input current stabilised at 0,03A.
No hazard.
C572
-
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
C572
-
S-c
253
10 min.
F101
0,03 A
Unit shut down immediately.
Input current stabilised at 0,03A.
No component damaged.
No hazard.
Input current stabilised at 0,03A.
No component damaged.
No hazard.
D502
AC - “+”
S-c
253
10 min.
F101,
F501,
F502
F501,
F502
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
D502
AC - “-”
S-c
253
30 min.
F101,
F501,
F502
F501,
F502
3,42 A
Normal operated.
Input current stabilised at 2,76A.
F502 opened.
No hazard.
Input current stabilised at 2,76A.
F502 opened.
No hazard.
C509
-
S-c 253
10
min. F101,
F501,
F502
F502
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
D505
AC - “+”
S-c 253
15
min. F101,
F505,
F506
F506
2,73 A
DC Fan motor stop immediately.
Unit shut down after 9min. 32sec.
Input current stabilised at 0,06A.
F505 opened.
No hazard.
Unit shut down after 9min. 32sec.
Input current stabilised at 0,06A.
F505 opened.
No hazard.
D505
AC - “+”
S-c 253
15
min. F101,
F505,
F506
F506
2,55 A
DC Fan motor stop immediately.
Unit shut down after 8min. 15sec.
Input current stabilised at 0,03A.
F505 opened.
No hazard.
Unit shut down after 8min. 15sec.
Input current stabilised at 0,03A.
F505 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
TRF No: IEC/EN 60065F
- Page 3 of 8 -
Order
No.
72390
11
FAULT CONDITON TESTS -continued
P
Comp.
No.
No.
Location
Fault Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
D505
AC - “-”
S-c 253
15
min. F101,
F505,
F506
F506
2,73 A
DC Fan motor stop immediately.
Unit shut down after 8min. 52sec.
Input current stabilised at 0,06A.
F505 opened.
No hazard.
Unit shut down after 8min. 52sec.
Input current stabilised at 0,06A.
F505 opened.
No hazard.
C517
-
S-c 253
10
min. F101,
F505,
F506
F506
2,73 A
DC Fan motor stop immediately.
Unit shut down after 6min. 15sec.
Input current stabilised at 0,06A.
F506 opened.
No hazard.
Unit shut down after 6min. 15sec.
Input current stabilised at 0,06A.
F506 opened.
No hazard.
D701
AC - “+”
S-c 253
20
min. F101,
F701,
F702
F702
0,88 A
Output signal off immediately.
Input current stabilised at 0,88A.
F701, F702 opened.
No hazard.
Input current stabilised at 0,88A.
F701, F702 opened.
No hazard.
D701
AC - “+”
S-c 207
10
min. F101,
F701,
F702
F702
0,60 A
Output signal off immediately.
Input current stabilised at 0,60A.
F701 opened.
No hazard.
Input current stabilised at 0,60A.
F701 opened.
No hazard.
C706
-
S-c 253
20
min. F101,
F701,
F702
F702
0,88 A
Output signal off immediately.
Unit shut down after 15min. 2sec.
Input current stabilised at 0,06A.
F702 opened.
No hazard.
Unit shut down after 15min. 2sec.
Input current stabilised at 0,06A.
F702 opened.
No hazard.
Q334
E - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
Q336 damaged.
No hazard.
Input current stabilised at 0,06A.
Q336 damaged.
No hazard.
Q334
B - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
C304
-
S-c
253
30 min.
F101
2,53 A
Normal operated.
Input current stabilised at 2,53A.
R352 opened.
No hazard.
Input current stabilised at 2,53A.
R352 opened.
No hazard.
Q336
E - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
Q334 damaged.
No hazard.
Input current stabilised at 0,06A.
Q334 damaged.
No hazard.
Q336
B - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
TRF No: IEC/EN 60065F
Click on the first or last page to see other AVR 445 (serv.man2) service manuals if exist.