- Page 31 of 31 - 
 
 
 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
No TNV circuits 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
Class II apparatus. 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
No CRT 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
 N 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
 N 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
 N 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
 N 
 
IT: user instructions in Italian language including a 
conformity declaration 
 N 
 
IT: certification number on the back cover 
 N 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No switches containing 
mercury 
N
 
TRF No:  IEC/EN 60065F 
 
 
- Page 1 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
ATTACHMENT: Tables to EN/IEC 60065 7
th
 edition
 
 
 
 
9.1.1.1 
Touch current expressed as voltages U1 and U2 in Annex D 
Location Measured 
U1V 
(peak) 
Measured U1
V (DC) 
Measured U2 
V (peak) 
Limits :  
U1 Max 35V (peak) 
U1 Max  1.1V (DC) 
U2 Max 0.35V (peak)
Mains pole 1 – Antenn terminal 
Mains pole 2 – Antenn terminal 
- - 
<0,05Vpeak 
Pass 
Mains pole 1 – other part or contact 
Mains pole 2 – other part or contact 
- - 
<0,05Vpeak 
Pass 
 
 
 
 
 
 
 
 
 
 
Comments: 
Only U2 have been recorded due to the use of a linear transformer in power supply. 
 
 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 2 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
11 
FAULT CONDITIONS TESTS 
 
Voltage(V) 0,9 or 1,1 times rated voltage………. 
207V or 253V 
— 
 
Ambient temperature(℃)…………………………… 
23 - 26°C 
— 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D801 
AC - “+” 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
Input current stabilised at 0,06A. 
No hazard. 
D801 
AC - “+” 
S-c 
207 
1 sec. 
F101 
F101 opened immediately. 
Input current stabilised at 0,03A. 
No hazard. 
C572 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
C572 
S-c 
253 
10 min. 
F101 
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
D502 
AC - “+” 
S-c 
253 
10 min. 
F101, 
F501, 
F502 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
D502 
AC - “-” 
S-c 
253 
30 min. 
F101, 
F501, 
F502 
3,42 A 
Normal operated. 
Input current stabilised at 2,76A. 
F502 opened. 
No hazard. 
C509 
S-c 253 
10 
min. F101, 
F501, 
F502 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
D505 
AC - “+” 
S-c 253 
15 
min. F101, 
F505, 
F506 
2,73 A 
DC Fan motor stop immediately. 
Unit shut down after 9min. 32sec.
Input current stabilised at 0,06A. 
F505 opened. 
No hazard. 
D505 
AC - “+” 
S-c 253 
15 
min. F101, 
F505, 
F506 
2,55 A 
DC Fan motor stop immediately. 
Unit shut down after 8min. 15sec.
Input current stabilised at 0,03A. 
F505 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 
 
 
- Page 3 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
11 
FAULT CONDITON TESTS -continued 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D505 
AC - “-” 
S-c 253 
15 
min. F101, 
F505, 
F506 
2,73 A 
DC Fan motor stop immediately. 
Unit shut down after 8min. 52sec.
Input current stabilised at 0,06A. 
F505 opened. 
No hazard. 
C517 
S-c 253 
10 
min. F101, 
F505, 
F506 
2,73 A 
DC Fan motor stop immediately. 
Unit shut down after 6min. 15sec.
Input current stabilised at 0,06A. 
F506 opened. 
No hazard. 
D701 
AC - “+” 
S-c 253 
20 
min. F101, 
F701, 
F702 
0,88 A 
Output signal off immediately. 
Input current stabilised at 0,88A. 
F701, F702 opened. 
No hazard. 
D701 
AC - “+” 
S-c 207 
10 
min. F101, 
F701, 
F702 
0,60 A 
Output signal off immediately. 
Input current stabilised at 0,60A. 
F701 opened. 
No hazard. 
C706 
S-c 253 
20 
min. F101, 
F701, 
F702 
0,88 A 
Output signal off immediately. 
Unit shut down after 15min. 2sec.
Input current stabilised at 0,06A. 
F702 opened. 
No hazard. 
Q334 
E - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
Q336 damaged. 
No hazard. 
Q334 
B - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
C304 
S-c 
253 
30 min. 
F101 
2,53 A 
Normal operated. 
Input current stabilised at 2,53A. 
R352 opened. 
No hazard. 
Q336 
E - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
Q334 damaged. 
No hazard. 
Q336 
B - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 