Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online
- Page 8 of 8 -
Order
No.
72390
14.3.3
Transformer/motor, constructional requirements
P
Clearances / Creepage distances
Transformer
Part No.
Part No.
Insulation
between
between
Insulation Res.
M Ohms
Test Volt
kV (60 sec.)
Measured
Required
H03-TXPWMEI92B0R
Pri. - Sec.
> 100
3000Vac
9,0 / 9,0mm
4,0 / 5,8mm
Pri. - ic
> 100
3000Vac
8,5 / 8,5mm
4,0 / 5,0mm
H03-TXPWMEI45B0R
Pri. - Sec.
> 100
3000Vac
6,8 / 6,8mm
4,0 / 5,4mm
Pri. - ic
> 100
3000Vac
6,1 / 6,5mm
4,0 / 5,0mm
-
Components / construction
(H03-TXPWMEI92B0R)
Windings on two separate bobbins. The bobbins are placed in
an insulating housing with two compartments, one above the
other. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 387Vpeak / 274Vrms
an insulating housing with two compartments, one above the
other. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 387Vpeak / 274Vrms
P
-
Components / construction
(H03-TXPWMEI45B0R)
Windings on single bobbins. Center wall (2 layers) is provided
between primary and secondary windings. Satisfactory
constructed. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 374Vpeak / 264Vrms
between primary and secondary windings. Satisfactory
constructed. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 374Vpeak / 264Vrms
P
Transformer
Part No
Part No
Insulation
Between
Between
Thick (mm)
X Number
Material
Dielectric strength test
60 sec.
H03-TXPWMEI92B0R
Pr - sec
0,80 mm min. x 1
PBT bobbin
1 layer tested - Pass *)
Pr - ic
0,80 mm min. x 1
PBT bobbin
1 layer tested - Pass *)
H03-TXPWMEI45B0R
Pr - sec
0,40 mm min. x 2
0,40 mm min. x 1
0,40 mm min. x 1
PET bobbin wall
PBT bobbin cap.
PBT bobbin cap.
1 layer tested - Pass *)
Pr - ic
0,60 mm min. x 1
PET bobbin
1 layer tested - Pass *)
Pr - ic
0,40 mm min. x 1
PBT bobbin cap.
1 layer tested - Pass *)
*) Test voltage: 3000 Vrms.
17.1
Torque test to Table 20:
P
Material
Screw
Location / function
Location / function
Diameter
(mm)
(mm)
With
Head
Without
Head
Screw
Nut
Torque test (Nm)
Fulfilled / Remarks
Fixing of top cover
(Sides)
(Sides)
4
x
Metal
Metal
Tested with 1,2Nm,
5 times / Pass
5 times / Pass
Fixing of top cover
(Rear)
(Rear)
3
x
Metal
Metal
Tested with 0,5Nm,
5 times / Pass
5 times / Pass
TRF No: IEC/EN 60065F
- IEC 60065 7
th
edition (2001)
- Page 1 of 1 -
Order
No.
72390
APPENDIX: SINGAPORE DEVIATIONS
to IEC 60065 7
th
ed. (2001)
(CB Bulletin No. 105A, May 2003)
Clause
Requirement – Test
Result - Remark
Ver-
dict
4
All apparatus must be tested to 230 Vac
230 Vac covered
P
4.3.13
Apparatus fitted with voltage selector switch must
be tested as follows:
be tested as follows:
Connect apparatus to 230 V ac mains with voltage
selector switch to settings not suitable for operation
at 230 V ac.
selector switch to settings not suitable for operation
at 230 V ac.
No voltage selector.
N
5.3
Circuit diagrams must be indicated with component
values.
values.
P
Circuit diagrams of electronic modules in the
apparatus must be provided.
apparatus must be provided.
P
7.1, 11.2
Permissible temperature rises of 10K less than
those specified in Table 2 are required.
those specified in Table 2 are required.
Meets tropical limits
P
10.2
Humidity treatment. Adopt the testing conditions
designed for tropical conditions.
designed for tropical conditions.
5 days
P
15.1.1
All Class I apparatus must be fitted with 3-pin mains
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
Class II
N
a) All Class II apparatus must be fitted with 2-pin
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
P
b) Class II apparatus that are fitted with 3-pin mains
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
P
15.3
Apparatus ≥ 3 kW must be connected to fixed
wiring. All connection to fixed wiring must be in
accordance with Code of Practice CP5.
accordance with Code of Practice CP5.
< 3 kW
N
16
Detachable power cord set must be listed in the test
report critical component list.
report critical component list.
See summary of testing
N
Misc.
Apparatus enclosure which is shaped and
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
Not shaped like toy.
P
TRF No: IEC/EN 60065F
- Page 1 of 3 -
PHOTOS
Order
No.
72390
TRF No: IEC/EN 60065F
- Page 2 of 3 -
PHOTOS
Order
No.
72390
TRF No: IEC/EN 60065F
Click on the first or last page to see other AVR 445 (serv.man2) service manuals if exist.