Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online
-
Page
23
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20
RESISTANCE TO FIRE
P
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
FV 1 or better, and exception
is made for small components.
FV 1 or better, and exception
is made for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
N
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No wires working at voltages
> 4kV or leaving an internal
fire enclosure
> 4kV or leaving an internal
fire enclosure
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
All PCB are of base material
with flammability category
FV 1 or better. See List of
Critical Components.
with flammability category
FV 1 or better. See List of
Critical Components.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Bobbin material of mains
transformer is rated 94V-0.
transformer is rated 94V-0.
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement.
no fire enclosure requirement.
N
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N
TRF No: IEC/EN 60065F
-
Page
24
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
N
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N
A.10.2.1
Enclosure provides protection against splashing
water
water
N
A.10.2.2 Humidity
treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
N
Complies with IEC 62151 clause 1
No TNV circuits
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
IEC 62151 clause 4.1.1:
Add after the first paragraph:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a
non-industrial appliance coupler or both and in
addition is intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
equipment which is intended for connection to the
building installation via a non-industrial plug or a
non-industrial appliance coupler or both and in
addition is intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
be as follow:
In Finland;
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
In Norway; ”Apparatet mǻ tikoples jordet
stikkontakt”
stikkontakt”
In Sweden; ”Apparaten skall anslutas till jordat
uttag”
uttag”
Class II apparatus
N
TRF No: IEC/EN 60065F
-
Page
25
of
31
-
www.nemko.com
Report No.
72390
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is less
then 8,7W
the power consumption is less
then 8,7W
P
Position of the functional switch (W) ...................... :
—
Operating conditions
Standy mode:
Un (V)
In (A)
Pn (W)
Pout (W)
207 0,033 6,1 —
230 0,037 7,2 —
253 0,055 8,7 —
Measured at maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
253
5,70
1218
F)
2 x 87,5 W
S)
2 x 88,8 W
C)
1 x 87,8 W
S/B) 2 x 90,0 W
Measured at 1/8 of maximum non-clipped output:
253 2,73
#) 2,56
533
#) 500
F)
2 x 10,9 W
S)
2 x 11,1 W
C)
1 x 11,0 W
S/B) 2 x 11,3 W
230 2,65
#) 2,45
472
#) 436
F)
2 x 10,9 W
S)
2 x 11,1 W
C)
1 x 11,0 W
S/B) 2 x 11,3 W
207 2,55
#) 2,35
414
#) 379
F)
2 x 10,9 W
S)
2 x 11,1 W
C)
1 x 11,0 W
S/B) 2 x 11,3 W
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads connected conditions for
F, S, C and S/B channels, and than replaced the input signal to pink noise for heating and fault condition tests.
F, S, C and S/B channels, and than replaced the input signal to pink noise for heating and fault condition tests.
The values followed #) mark in table above are measured “A” or “W” value, when replaced the input signal
from 1 kHz sign wave to pink noise.
from 1 kHz sign wave to pink noise.
Loudspeaker impedance (Ω) ................................. :
8 Ω
—
Several loudspeaker systems
Only one for Center,
Right and Left for Surround,
Right and Left for Surround,
Right and Left for Front,
Right and Left for Surround
Back channels.
Right and Left for Surround
Back channels.
P
Marking of loudspeaker terminals
SPEAKERS ( 8 Ω ) :
FR, FL, SR, SL, CENTER,
SBR/MULTI R, SBL/MULTI L
SBR/MULTI R, SBL/MULTI L
.
P
TRF No: IEC/EN 60065F
-
Page
26
of
31
-
www.nemko.com
Report No.
72390
Monitored point:
dT (K) at 207V dT (K) at 253V
Limit dT (K)
*)
Appliance inlet body
15,7 16,7
60
Main transformer core
62,7 73,4
95
Sub transformer core
39,2 54,2
85
E. Capacitor, C201 body
31,0 35,1
85
o
C
IC11 heat-sink
34,9 44,0
-
PWB near D201
43,0 47,0
85
Diode, D201 body
61,4 66,5
-
PWB near Q318
40,2 49,9
85
PWB near D601
22,2 22,7
85
PWB near D801
48,9 57,7
85
PWB near D701
32,6 36,6
85
Fan guard
24,3 26,6
60
PWB near Q334
34,0 43,2
85
E. Capacitor, C572 body
24,0 27,0
85
o
C
IC54 heat-sink
29,9 49,1
-
PWB near D502
25,4 28,8
85
PWB near IC54
30,2 49,2
85
Main heat-sink
44,6 49,5
-
Top enclosure above main transformer
5,5 4,9
40
Top enclosure above main heat-sink
13,0 15,3
40
Switch button
2,7 3,1
50
*) Temperature rise limits for Singapore is 10K less.
Test Condition: Pink noise input signal and 8 ohm loads connected conditions for F, C, S and S/B channels.
Winding temperature rise measurements
207V 253V
Ambient temperature t1 (
o
C) .................................. :
24,0 24,0
—
Ambient temperature t2 (
o
C) .................................. :
24,0 26,5
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Main trans. primary winding (at 1/8Pmax), 207V
1,925 2,473 73,6 95
B
Sub trans. primary winding (at 1/8Pmax), 207V
269,7 309,0 37,7 85
E
Main trans. primary winding (at 1/8Pmax), 253V
1,925 2,551 81,6 95
B
Sub trans. primary winding (at 1/8Pmax), 253V
269,7 327,0 52,4 85
E
TRF No: IEC/EN 60065F
Click on the first or last page to see other AVR 445 (serv.man2) service manuals if exist.