FAULT CONDITON TESTS -continued 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
Q518 
E - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
Q519 damaged. 
No hazard. 
Q518 
B - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
C501 
S-c 
253 
30 min. 
F101 
2,51 A 
Normal operated. 
Input current stabilised at 2,51A. 
R525 opened. 
No hazard. 
Q519 
E - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
Q518 damaged. 
No hazard. 
Q519 
B - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
D601 
AC - “+” 
S-c 253 
30 
min. F101, 
F601, 
F602 
2,72 A 
Normal operated. 
Input current stabilised at 2,72A. 
F602 opened. 
No hazard. 
D601 
AC - “+” 
S-c 207 
30 
min. F101, 
F601, 
F602 
2,55 A 
Normal operated. 
Input current stabilised at 2,55A. 
F602 opened. 
No hazard. 
C606 - 
S-c 253 
30 
min. F101, 
F601, 
F602 
2,69 A 
Normal operated. 
Input current stabilised at 2,69A. 
F601, F602 opened. 
No hazard. 
D201 
AC - “+” 
S-c 253 
sec.  F101  - 
F101 opened immediately. 
Input current stabilised at 0,06A. 
No hazard. 
D201 
AC - “+” 
S-c 207 
sec.  F101  - 
F101 opened immediately. 
Input current stabilised at 0,03A. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 
 
 
- Page 5 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
11 
FAULT CONDITON TESTS –continued 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
C202 - 
S-c 253 
10 
min. F101 
10,7 A 
F101 opened after 32sec. 
Input current stabilised at 0,06A. 
Main transformer damaged. 
Dielectric strength test OK. 
No hazard. 
C202 - 
S-c 207 
10 
min. F101 
10,3 A 
F101 opened after 1min. 4sec. 
Input current stabilised at 0,03A. 
Main transformer damaged. 
Dielectric strength test OK. 
No hazard. 
D105 
A - C 
S-c 253 
hr. 
20 min. 
F101 
2,72 A 
Normal operated. 
Input current stabilised at 2,72A. 
Sub transformer primary winding 
heated up to 105K and stabilised.
Dielectric strength test OK. 
No hazard. 
C215 - 
S-c 
253 
26 min. 
F101 
0,09 A 
Sub transformer primary winding 
heated up to 145K and thermal 
fuse opened after 26 min. 
Dielectric strength test OK. 
No hazard. 
D112 
A - C 
S-c 
253 
58 sec. 
F101 
2,93 A 
Sub transformer primary winding 
heated up to 151K and thermal 
fuse opened after 58 sec. 
Dielectric strength test OK. 
No hazard. 
 
(Repeated test two more times 
with similar result) 
 
- T/F opened at 152K after 57 sec.
- T/F opened at 155K after 55 sec.
No hazard. 
C116 - 
S-c 253 
min. 
4 sec. 
F101 3,00 
Sub transformer primary winding 
heated up to 152K and thermal 
fuse opened after 1 min. 4 sec. 
Dielectric strength test OK. 
No hazard. 
(Repeated test two more times 
with similar result) 
 
- T/F opened at 151K after 58 sec.
- T/F opened at 153K after 57 sec.
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 
 
 
- Page 6 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
11 
FAULT CONDITON TESTS -continued 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
Speaker 
terminal 
(Front) 
R - G 
S-c 253 
10 min 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
Cover 
opening 
Blocked 
253 
Top 
5 hr 
F101 
2,73 A 
Normal operated. 
The components are heated up to: 
- Main transf. pr. winding : 80K 
- Main transformer core : 68K 
- Sub transf. pr. winding : 51K 
- Sub transformer core  : 52K 
- PWB near D201 
: 41K 
- PWB near Q334 
: 37K 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
Fan Locked 
253 
min. 
30 sec. 
F101 
2,73 A 
Unit shut down after 4min. 30sec.
Input current stabilised at 0,06A. 
No component damaged. 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
Pmax 
operat. 
Maximum 
non-
clipped 
output 
signal 
253 
7 min. 
F101 
5,70 A 
The components are heated up to:
- Main transf. pr. winding  : 143K 
- Main transformer core  : 90K 
- Sub transf. pr. winding  : 60K 
- Sub transformer core 
: 58K 
- PWB near D201 
: 74K 
- PWB near Q334 
: 38K 
and main transformer thermal 
fuse opened after 7 min. 
Dielectric strength test OK. 
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 
 
 
- Page 7 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
13.3 – 13.4 
Clearances and Creepage distances 
 
Position/ 
Location 
Position/ 
Location 
Working 
Voltage (V) 
Clearance 
13.3.2 
Creepage dist 
13.4 
Type of  
Insulation 
1 2 
Up 
Urms
Req. 
Measu.
Req. 
Measu. 
Comm.
Basic Live  Neutral 326 
230 
2,0mm
3,7mm 
2,5mm 
3,7mm 
1) 
Reinforced Primary 
Inlet 
screw 
sec. 
326 230 4,0mm
5,4mm 
5,0mm 
5,4mm 2) 
Reinforced SK11 
pr. pattern. 
C201 
sec. 
pattern. 
388 274 4,0mm
8,6mm 
5,8mm 
8,6mm 2) 
Reinforced Pr. 
Phase 
Sec. Gnd 
326 
230 
4,0mm
16,0mm 5,0mm 
16,0mm 
2) 
Reinforced Primary 
Accessible 
metal part 
326 230 4,0mm
7,3mm 
5,0mm 
7,3mm 3) 
Reinforced Sub 
transf. 
pr. 
Sub transf. 
core 
326 230 4,0mm
6,1mm 
5,0mm 
6,5mm 4) 
Reinforced Sub 
transf. 
pr.  
Sub transf. 
sec. 
373 264 4,0mm
6,8mm 
5,4mm 
6,8mm 4) 
Reinforced Main 
transf. 
pr. 
Main transf. 
core 
326 230 4,0mm
8,5mm 
5,0mm 
8,5mm 5) 
Reinforced Main 
transf 
pr.  
Main transf 
sec. 
388 274 4,0mm
9,0mm 
5,8mm 
9,0mm 5) 
 
 
 
 
 
 
 
 
 
 
Note: U in Volt, Clearances/Creepage Distances in mm, Comm.=Comment 
Comments: 
1) Before main fuse 
2) Measured on PCB 
3) Measured between primary and 
accessible
 metal chassis 
4) Measured in sub transformer 
5) Measured in main transformer 
 
TRF No:  IEC/EN 60065F 