Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online
-
Page
15
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.4
High voltage components
No high-voltage components.
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
P
Protective devices used within their ratings
Approved fuses and thermal
links
links
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Adequate external clearance
and creepage distance
and creepage distance
P
14.5.1.1
a) Thermal cut-outs separately approved
None
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
The thermal link in main and
sub transformers are
separately approved, see list
of critical components.
separately approved, see list
of critical components.
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved according
to IEC 60127, see list of
critical cmponents
to IEC 60127, see list of
critical cmponents
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied close
to the fuses;
- Primary fuses,
F101: T5A L 250V
F201: T2A L 250V
- Secondary fuses,
F501, F502, F505, F506:
T2A 250V
F601, F602, F701, F702:
T3.15A 250V
to the fuses;
- Primary fuses,
F101: T5A L 250V
F201: T2A L 250V
- Secondary fuses,
F501, F502, F505, F506:
T2A 250V
F601, F602, F701, F702:
T3.15A 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed
that fuse-links can be
connected in parallel
that fuse-links can be
connected in parallel
P
TRF No: IEC/EN 60065F
-
Page
16
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s
N
PTC-S devices (15 W) category V-1 or better
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No other protective devices
N
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
Yes,
Mains switch and relay provided.
Certified acc. to IEC61058-1.
-Mains switch, certified by
VDE,
-Mains relay, certified by
SEMKO.
See appended table, list of
critical components.
Mains switch and relay provided.
Certified acc. to IEC61058-1.
-Mains switch, certified by
VDE,
-Mains relay, certified by
SEMKO.
See appended table, list of
critical components.
P
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved switch
and relay
and relay
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved switch
and relay
and relay
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay
and relay
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
Measured surge current
through,
- Relay=49A+20A* = 69A total
- Switch = < 2A.
*) Surge current value for
switched outlet, 0.5A = 20A.
The measured surge current
value is less than rated surge
current rating of the mains
switch and relay. OK.
through,
- Relay=49A+20A* = 69A total
- Switch = < 2A.
*) Surge current value for
switched outlet, 0.5A = 20A.
The measured surge current
value is less than rated surge
current rating of the mains
switch and relay. OK.
P
TRF No: IEC/EN 60065F
-
Page
17
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Socket outlet current marking correct
“SWITCHED, 100W, 0.5A
MAX” marked
MAX” marked
P
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of IEC 60950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
No voltage setting devices
N
14.9 Motors
DC brush-less fan motor
P
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
Only DC supplied
N
14.9.2
Not adversely affected by oil or grease etc.
The fan is not adversely
affected by oil, grease or other
substances
affected by oil, grease or other
substances
P
14.9.3
Protection against moving parts
The fan is placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
No batteries
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11 Optocouplers
N
Optocouplers comply with Cl. 8
No optocouplers.
N
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N
TRF No: IEC/EN 60065F
-
Page
18
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.12
Surge suppression varistors
N
Comply with IEC 61051-2
No surge suppression varistors
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved appliance inlet and
mains socket-outlet provided,
See list of critical components.
mains socket-outlet provided,
See list of critical components.
P
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Only phono/RCA, Optical,
Antenna, RS-232C, A-BUS,
Mini jack, HDMI, USB, DMP
and S-video terminals used.
Banana plug type speaker
terminal also used, but they
are accepted due to below
note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
Antenna, RS-232C, A-BUS,
Mini jack, HDMI, USB, DMP
and S-video terminals used.
Banana plug type speaker
terminal also used, but they
are accepted due to below
note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with the
symbol
symbol
N
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
The equipment under test is
not an adaptor.
not an adaptor.
N
15.2
Provision for protective earthing
N
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus
N
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
output voltage: output circuit not connected to
earth
N
Protective earth conductors correctly coloured
N
TRF No: IEC/EN 60065F