Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online
-
Page
3
of
31
-
www.nemko.com
Report No.
72390
Copy of marking plate:
TRF No: IEC/EN 60065F
-
Page
4
of
31
-
www.nemko.com
Report No.
72390
Summary of testing:
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus have Front / Center / Surround / Surround Back (Multi) amplifier circuits, Tuner circuit,
RCA, Antenna, Optical, S-video, HDMI, Mini jack, A-bus, RS-232C, USB, DMP and speaker terminals
(see also photos).
The apparatus have Front / Center / Surround / Surround Back (Multi) amplifier circuits, Tuner circuit,
RCA, Antenna, Optical, S-video, HDMI, Mini jack, A-bus, RS-232C, USB, DMP and speaker terminals
(see also photos).
The equipment applied condition of tropical climates for Singapore.
Instructions : Instructions/users manual is only in English. The information shall be given in a language
acceptable to the country where the apparatus is intended to be sold.
Mains cord set : This test report does not cover the mains cord set. Must be supplied with an approved
cord set suitable for the countries where the requirement will be sold.
Instructions : Instructions/users manual is only in English. The information shall be given in a language
acceptable to the country where the apparatus is intended to be sold.
Mains cord set : This test report does not cover the mains cord set. Must be supplied with an approved
cord set suitable for the countries where the requirement will be sold.
List of attachments:
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITONS.
ANNEX ZC TO EN 60 065, A-DEVIATIONS.
Attachment, Tables to EN/IEC 60065 7
ANNEX ZC TO EN 60 065, A-DEVIATIONS.
Attachment, Tables to EN/IEC 60065 7
th
edition.
National Deviations for Singapore
Photos.
Circuit Diagram (Power Supply Section)
TRF No: IEC/EN 60065F
-
Page
5
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II apparatus.
P
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
No test box required. Tested
according to manufacturers
instructions.
according to manufacturers
instructions.
P
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit
P
5.1 Identification,
maker, model ................................... :
Brand: Harman / kardon
Model: AVR 445
See copy of marking plate.
Model: AVR 445
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172
according to IEC 60417-5172
P
Rated supply voltage and symbol .......................... :
AC-symbol (
~
) and
230V marked
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ..................... :
1000 W
P
5.2 Earth
terminal
Class II apparatus
N
Hazardous live terminals
No live terminals.
The output signal will rise to
43Vp at Pmax, if the speaker
terminal is disconnected.
No hazard.
The output signal will rise to
43Vp at Pmax, if the speaker
terminal is disconnected.
No hazard.
P
Supply output terminals (other than mains)
The power is marked close to
the socket outlet.
”SWITCHED, 100W, 0.5A
MAX” marked
the socket outlet.
”SWITCHED, 100W, 0.5A
MAX” marked
P
5.3
Use of triangle with exclamation mark
Correct symbol applied:
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found.
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found.
P
TRF No: IEC/EN 60065F
-
Page
6
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary of
testing.
following language: English.
See comments in Summary of
testing.
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals.
N
Instructions for replacing lithium battery
No lithium battery in the
equipment
equipment
N
Instructions for modem if fitted
None
N
Class I earth connection warning
Class II apparatus
N
Instructions for multimedia system connection
Not applicable
N
Special stability warning for fixed installation
No such equipment
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Appliance coupler is
disconnecting device.
Adequate information included
in “User manual”
disconnecting device.
Adequate information included
in “User manual”
P
Instructions for permanently connected equipment
Not permanently connected
equipment
equipment
N
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No Ionizing radiation.
N
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
No laser radiation.
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during
normal operating operation.
(see appended table)
normal operating operation.
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
TRF No: IEC/EN 60065F