DOWNLOAD Harman Kardon AVR 445 (serv.man2) Service Manual ↓ Size: 1.96 MB | Pages: 46 in PDF or view online for FREE

Model
AVR 445 (serv.man2)
Pages
46
Size
1.96 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-445-sm2.pdf
Date

Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate ▷ View online

  
Page 
3
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
Copy of marking plate: 
 
 
 
 
 
 
 
TRF No:  IEC/EN 60065F 
  
Page 
4
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
Summary of testing: 
 
The apparatus under test is A/V Surround Receiver of insulation class II. 
The apparatus have Front / Center / Surround / Surround Back (Multi) amplifier circuits, Tuner circuit, 
RCA, Antenna, Optical, S-video, HDMI, Mini jack, A-bus, RS-232C, USB, DMP and speaker terminals 
(see also photos).
 
 
The equipment applied condition of tropical climates for Singapore. 
 
Instructions : Instructions/users manual is only in English. The information shall be given in a language 
acceptable to the country where the apparatus is intended to be sold. 
 
Mains cord set : This test report does not cover the mains cord set. Must be supplied with an approved 
cord set suitable for the countries where the requirement will be sold.
 
 
List of attachments: 
 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITONS. 
 
ANNEX ZC TO EN 60 065, A-DEVIATIONS. 
 
Attachment, Tables to EN/IEC 60065 7
th
 edition. 
 
National Deviations for Singapore 
 
Photos. 
 
Circuit Diagram (Power Supply Section) 
 
 
 
TRF No:  IEC/EN 60065F 
  
Page 
5
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus ................................. :
Class II apparatus. 
 
 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
No test box required. Tested 
according to manufacturers 
instructions. 
 
 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
On front and rear side of the 
enclosure 
 
Permanent durability against water and petroleum 
spirit 
Tested with water / sprit 
5.1 Identification, 
maker, model ................................... :
Brand: Harman / kardon 
Model: AVR 445 
See copy of marking plate. 
 
Class II symbol if applicable 
Class II symbol is applied in 
according to IEC 60417-5172 
 
Rated supply voltage and symbol .......................... :
AC-symbol ( 
~
 ) and 
230V marked 
 
Frequency if safety dependant 
50Hz 
 
Rated current or power consumption ..................... :
1000 W 
5.2 Earth 
terminal 
Class II apparatus 
 
Hazardous live terminals 
No live terminals. 
The output signal will rise to 
43Vp at Pmax, if the speaker 
terminal is disconnected. 
No hazard. 
 
Supply output terminals (other than mains) 
The power is marked close to 
the socket outlet. 
”SWITCHED, 100W, 0.5A 
MAX” marked 
5.3 
Use of triangle with exclamation mark 
Correct symbol applied: 
Imprinted on rear side in 
connection with CAUTION of 
opening. Further; no incorrect 
use of this symbol is found. 
TRF No:  IEC/EN 60065F 
  
Page 
6
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
5.4 
Instructions for use 
User information in the 
following language: English. 
See comments in Summary of 
testing. 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
The user manual includes 
information about danger 
concerning dripping or 
splashing and objects filled 
with liquids. 
 
Hazardous live terminals, instructions for wiring 
No hazardous live terminals. 
 
Instructions for replacing lithium battery 
No lithium battery in the 
equipment 
 
Instructions for modem if fitted 
None 
 
Class I earth connection warning 
Class II apparatus 
 
Instructions for multimedia system connection 
Not applicable 
 
Special stability warning for fixed installation 
No such equipment 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
Appliance coupler is 
disconnecting device. 
Adequate information included 
in “User manual” 
 
Instructions for permanently connected equipment
Not permanently connected 
equipment 
 
 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No Ionizing radiation. 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... :
No laser radiation. 
 
Emission limits under fault conditions .................... :
 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
No fuse links operate during 
normal operating operation. 
(see appended table) 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 