www.nemko.com
 
Report No. 
72390 
 
 
 
10.3 
TABLE: insulation resistance measurements 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
>100 2 
Between parts separated by double or reinforced insulation 
>100 4 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
1500V No 
Between parts separated by double or reinforced insulation 
3000V No 
TRF No:  IEC/EN 60065F 
 
 
- Page 28 of 31 - 
 
 
 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
 
14 
TABLE: list of critical components and materials 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Main transf. 
 
 
Bobbin Mtl. 
  
Thermal fuse
 
Seoul Elect. 
 
 
LG Chemical.  
 
NEC SCHOTT 
 
H03-TXPWME 
I92B0R 
 
GP-2306F(#) 
 
SF169E
 
230V, Class B 
 
 
94V-0, 140
°
 
10A/250V, 172
°
C
IEC60065 
clause 14.3 
 
UL94 
 
IEC60691
 
1.) 
 
 
UL 
E67171
 
 
VDE
 
Sub transf. 
(TP11) 
 
Bobbin Mtl. 
Bobbin cap. 
  
Thermal fuse 
Seoul Elect. 
 
 
Wintech Polymer.
 
LG Chemical. 
  
Anzen Dengu 
Co.
 
H03-TXPWME 
I45B0R 
 
CN9030
 
GP-1006(#) 
 
K5F
 
230V, Class E 
 
 
94V-0, 155
°
C
 
94V-0, 130
°
C
 
 
1A/250V, 136
°
C
 
IEC60065 
clause 14.3 
 
UL94 
UL94 
  
IEC60691
 
1.) 
 
 
UL 
E213445
 
UL 
E67171
 
  
VDE
 
Appliance 
inlet (NS30) 
alt. 
Zhangjiagang 
Huajie Elect.. 
I-SHENG 
SA-4S 
 
7014 
10A/250V 
 
10A/250V 
IEC60320 
 
IEC60320 
VDE 
 
VDE 
Mains Socket-
outlet (NS31) 
Dae Ryung 
Elect. 
A3-02-D006 2.5A/250V  IEC60884-1 NEMKO 
Mains switch 
Alps Electric 
Co., Ltd. 
SDL1P-D 
5A/80A 250V 
IEC 61058 
IEC 60065 
VDE 
BSI 
Mains relay 
(SK11) 
Tyco 
Electronics. 
SDT-S-112DMR 8A/120A 250V 
IEC60065 
IEC61058-1 
SEMKO 
Mains fuse 
(F201) 
alt. 
alt. 
Orisel Co., Ltd. 
 
Littelfuse Inc. 
Sun Elect. 
50T 
 
218 
002 
5T 
T2A L 250V 
IEC60127 
VDE 
 
VDE 
VDE 
Mains fuse 
(F101) 
alt. 
alt. 
Orisel Co., Ltd. 
 
Littelfuse Inc. 
Sun Elect. 
50T 
 
218 
005
 
5T 
T5A L 250V 
IEC60127 
VDE 
 
VDE 
VDE 
Sec. Fuse 
(F501, F502, 
F505, F506) 
alt. 
alt. 
alt. 
alt. 
Littelfuse. 
 
 
Bel Fuse. 
Save Fusetech. 
Schurter AG 
Walter Elect. 
0663 
 
 
MRT 
SR-5  
MST 
2000 
T2A L 250V 
IEC60127 
VDE 
 
 
VDE 
VDE 
VDE 
VDE 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 29 of 31 - 
 
 
 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
 
14 
TABLE: list of critical components and materials (continued) 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Sec. Fuse 
(F601, F602, 
F701, F702) 
alt. 
alt. 
alt. 
alt. 
Littelfuse. 
 
 
Bel Fuse. 
Save Fusetech. 
Schurter AG 
Walter Elect. 
0663 
 
 
MRT 
SR-5  
MST 
2000 
T3.15A 250V 
IEC60127 
VDE 
 
 
VDE 
VDE 
VDE 
VDE 
X-capacitor 
(C100) 
alt. 
alt. 
alt. 
alt. 
alt. 
Pilkor Elect. 
 
Pilkor Elect. 
Okaya. 
Yuchang Elect. 
Ultra Tech. 
BC Components. 
PCX2 335M 
 
PCX2 335 
RE104 
WBU1942 
HQX 
336 2 
0.10uF 275V 
X2 
IEC60384-14, 
2
nd
 ed. 
FIMKO 
 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
ENEC 
Relay across 
the capacitor 
(C101) 
 
alt. 
alt.  
alt. 
alt. 
alt. 
Du San 
Industrial. 
 
Netron Tech. 
Samwha Cap. 
Murata Mfg. 
Jyh Chung Elect. 
Guangdong 
Hongming
 
NU 
 
 
AA 
SC 
KH 
JY 
4700pF/250V, 
X1. 
IEC
60384-14, 
2
nd
 ed. 
FIMKO 
 
 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
Brush-less  
DC fan 
KAIMEI 
Electronic 
Corp. 
JF0925S1M-R 12V, 
0.20A 
TUV, 
1.) 
PCB base 
material 
Various Various Min 
94V-1 
130
°
UL 796 
UL 
Enclosure 
Front panel 
LG Chemical 
Ltd 
HIPS403AF 
HIPS, V-2 
UL94 
UL, E67171 
Enclosure 
FL window 
I-Components. 
CCL+ 
PC, V-2 
UL94 
UL, E226770 
Enclosure 
Chassis 
Various 
Sheet steel 
Min. 0,8mm 
 
 
 
 
 
 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
Reference 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 30 of 31 - 
 
 
 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
 
ZB 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Class II apparatus 
13.3.1 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
Class II apparatus
 
N
 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
Not supplied with a cord set. 
See summary of testing. 
 
DK: Class I equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
Class II apparatus
 
N
 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
Class II apparatus. 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
When marketing in U.K.,  
the apparatus must be 
supplied with a cord and plug 
acceptable in Ireland. 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
When marketing in Ireland,  
the apparatus must be 
supplied with a cord and plug 
acceptable in Ireland. 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
Comply 
P 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
Comply 
P 
 
- protecting rim also tested 
         
 
N
 
TRF No:  IEC/EN 60065F 
Page of 46
Display

Click on the first or last page to see other AVR 445 (serv.man2) service manuals if exist.