Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
11.2.1 
Measurement of temperature rises 
See attachment table and 
attachment, Table to 
EN/IEC 60065 7
th
 edition 
11.2.2 
Temperature rise of accessible parts 
See attachment table and 
attachment, Table to 
EN/IEC 60065 7
th
 edition 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
See attachment table and 
attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
No area where temperature 
exceeds 100K above limits 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
No conductors are 
interrupted/peeled/loosened 
during fault conditions 
 
Class I protective earthing maintained 
Class II apparatus
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
Temperature rises are within 
the limits. 
11.2.5 
Temperature rise of windings 
See attachment table and 
attachment, Table to 
EN/IEC 60065 7
th
 edition 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
No excessive temperature 
observed/measured on other 
parts 
 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
No damage in the sense of 
this standard. 
12.1.2 Vibration 
test 
Assessed to be satisfactory 
constructed 
12.1.3 
Impact hammer test 
No damage in the sense of 
this standard 
 
Steel ball test 
No damage in the sense of 
this standard 
TRF No:  IEC/EN 60065F 
  
Page 
12
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Not a portable apparatus. 
12.1.5 
Thermoplastic enclosures strain relief test 
No risk of shrinkage or 
distortion on enclosures 
12.2 
Fixing of knobs, push buttons, keys and levers 
Normal use will not impair the 
protection against electric  
shock 
12.3 
Remote controls with hazardous live parts 
No remote control containing 
hazardous live parts 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawers. 
12.5 
Antenna coaxial sockets providing isolation 
No antenna socket which 
isolate hazardous live parts 
from accessible parts. 
12.6 
Telescoping or rod antennas construction 
No telescoping or rod antennas 
12.6.1 
Telescoping or rod antennas securement 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
See attachment, Table to 
EN/IEC 60065 7
th
 edition.  
 
Creepage distances in accordance with 13.4 
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
13.2 
Determination of operating voltage 
Conventional transformer 
used. Upper rated supply 
voltage applied in determining 
the operating voltage.
 
P
 
13.3 Clearances 
2N forced applied for internal 
parts when determining 
clearances distances. 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
See attachment, Tables to 
EN/IEC 60065 7
th
 edition 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
No hazardous secondary 
voltages 
13.4 Creepage 
distances 
CTI > 100 
See attachment, Tables to 
EN/IEC 60065 7
th
 edition 
 
Creepage distances greater than table 11 minima 
Not applicable 
13.5 Printed 
boards 
 
TRF No:  IEC/EN 60065F 
  
Page 
13
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
No such PCB used 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
No type B coated printed circuit 
boards 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
No uncemented joints 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
No enclosed, enveloped or 
hermetically sealed parts 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No parts filled with insulating 
compound 
 
 
 
14 COMPONENTS 
 
14.1 Resistors 
N
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors
 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
Not used 
 
b) Resistors separately approved .......................... :  
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes, see below 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. :
No Y capacitors 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. :
Yes, C100 and C101 are 
cerified 
X capacitors by IEC 60384-14 
2
nd
 edition 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... :
No such capacitors 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Several E. cap. Vol. >1750mm
3
but metal cases.  
 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Several E. cap. Vol. >1750mm
3
but metal cases.  
 
TRF No:  IEC/EN 60065F 
  
Page 
14
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Shielded by a barrier to V-0 or metal  ..................... :
 
14.3 
Inductors and windings 
See below 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
Transformers evaluated 
according to 14.3.3, 14.3.4 and 
14.3.5 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ............................... :
Adequate marking applied 
- Type no. and, 
- Manufacturer’s ID 
 
Transformers and inductors separately approved . :
No 
14.3.2 General 
Isolating transformer 
 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
See attachment, Tables to 
EN/IEC 60065 7
th
 edition
 
14.3.3.2 
Transformers meet the constructional 
requirements 
See attachment, Tables to 
EN/IEC 60065 7
th
 edition
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between primary and 
secondary windings according 
to clause 8.8 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the 
requirement of reinforced 
insulation; bobbin 
thickness > 0,4 mm 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II apparatus. No such 
transformer used. 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between hazardous live 
winding 
and accessible conductive part. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the 
requirement of reinforced 
insulation; bobbin 
thickness > 0,4 mm 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Winding of Class II 
construction used. 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
TRF No:  IEC/EN 60065F 
Page of 46